Cubelet Icemaker / Dispenser
Models
DCM-750BAH(-OS)
DCM-750BWH(-OS)
INSTRUCTION MANUAL
“A Superior Degree
of Reliability”
www.hoshizaki.com
®
Issued: 5-7-2008
Revised: 4-6-2010
Resumo do conteúdo contido na página número 2
IMPORTANT Only qualified service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation. Failure to install, operate, and maintain the equipment in accordance with this manual may adversely affect safety, performance, comp
Resumo do conteúdo contido na página número 3
IMPORTANT This manual should be read carefully before the icemaker is installed and operated. Only qualified service technicians should install, service, and maintain the icemaker. Read the warnings contained in this booklet carefully as they give important information regarding safety. Please retain this booklet for any further reference that may be necessary. CONTENTS Important Safety Information ..............................................................................................
Resumo do conteúdo contido na página número 4
Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury. CAUTION Indicates a situation which could result in damage to the unit. IMPORTANT Indicates important information about the use and care of the unit. WARNING This icemaker should be destined only to the use for which it has been e
Resumo do conteúdo contido na página número 5
I. Specifications A. Nameplate Rating 1. DCM-750BAH (air-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER DCM-750BAH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 120V 1.8FLA(TOTAL) 110W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-460PSI LO-290PSI
Resumo do conteúdo contido na página número 6
2. DCM-750BAH-OS (air-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER DCM-750BAH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4 HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 120V 1.8FLA(TOTAL) 110W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-460PSI LO-290PSI REFRIGERANT 404A 1 lb. 7.1 oz.
Resumo do conteúdo contido na página número 7
3. DCM-750BWH (water-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER DCM-750BWH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 120V 1.8FLA(TOTAL) 110W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-460PSI LO-290PSI REFRIGERANT 404A 1 lb. 3 oz. MOTOR-C
Resumo do conteúdo contido na página número 8
4. DCM-750BWH-OS (water-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER DCM-750BWH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 120V 1.8FLA(TOTAL) 110W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-460PSI LO-290PSI REFRIGERANT 404A 1 lb. 3 oz. M
Resumo do conteúdo contido na página número 9
B. Dimensions/Connections 1. DCM-750BAH 9 Unit: in. [mm]
Resumo do conteúdo contido na página número 10
2. DCM-750BAH-OS 10 Unit: in. [mm]
Resumo do conteúdo contido na página número 11
3. DCM-750BWH 11 Unit: in. [mm]
Resumo do conteúdo contido na página número 12
4. DCM-750BWH-OS 12 Unit: in. [mm]
Resumo do conteúdo contido na página número 13
5. DCM-750BAH(-OS) or DCM-750BWH(-OS) on optional SD-700 or SD-750 Stand Unit: in. (mm) SD-700 SD-700 SD-700 SD-700 28-1/4" (718) 1/8" (3) 34" (864) 1/8" (3) SD-750 SD-750 28" (711) 34" (864) 13 6-1/8" SD-700 (156) 26-1/2" (673) SD-700 SD-750 80-11/16" (2050) 26-3/4" (680) SD-750 80-15/16" (2057)
Resumo do conteúdo contido na página número 14
II. Installation and Operating Instructions WARNING 1. This icemaker must be installed in accordance with applicable national, state, and local regulations. 2. CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the storage bin. A. Checks Before Installation • Visually inspect the exterior of the shipping container and immediately report any damage to the carrier. Upon opening the container, any con
Resumo do conteúdo contido na página número 15
B. How to Remove Panels See Fig. 1 or Fig. 2 • Front Panel: Remove the screw. Lift up and towards you. Disconnect the connectors on push-button models. • Top Panel: Lift up at front slightly, push rearward and lift off. • Apron Panel: Remove the screws and pull towards you. Disconnect the connectors on optical-sensor models. • Side Panel: Remove the screws and pull towards you. DCM-750B_H DCM-750B_H-OS (push-button models) (optical-sensor models) Top Panel Top Panel Side Panel Side Panel Fro
Resumo do conteúdo contido na página número 16
C. Location CAUTION 1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect icemaker performance. 2. This icemaker will not work at sub-freezing temperatures. To prevent damage to the water supply line, drain the icemaker if the air te
Resumo do conteúdo contido na página número 17
E. Electrical Connection WARNING 1. Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or extensive damage to equipment. 2. This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuses, or damage to e
Resumo do conteúdo contido na página número 18
F. Water Supply and Drain Connections See Fig. 4, 5, or 6 WARNING 1. Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations. 2. Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of this normal temperature range may affect icemaker performance. 3. To prevent damage to equipment, do not operate the icemaker when the water supply is off, or i
Resumo do conteúdo contido na página número 19
1. Icemaker • Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the icemaker water supply line. • An icemaker water supply line shut-off valve and drain valve should be installed. • Storage bin and drip tray drain outlets are 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for the storage bin and drip tray drain lines. Icemaker Icemaker Water Icemaker Water Supply Supply Inlet Line Shut-Off Valve 1/2" FPT Storage Bin
Resumo do conteúdo contido na página número 20
2. Water-Cooled Condenser a) Connection to an Open Drain System • Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line. • A condenser water supply line shut-off valve and drain valve should be installed. • Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser drain line. • In some areas, a back flow preventer may be required in the condenser water suppl