Resumo do conteúdo contido na página número 1
INSTALLATION &
OPERATIONAL MANUAL
GRM SERIES GAS
FRYERS
MODELS:
1GR35M ML-136407
1GR45M ML-136408
1GR65M ML-136409
1GR85M ML-136410
2GR45MF ML-136417
2GR65MF ML-136418
2GR85MF ML-136419
3GR45MF ML-136420
3GR65MF ML-136421
3GR85MF ML-136422
4GR45MF ML-136423
4GR65MF ML-136661
4GR85MF ML-136664
2XG45MF ML-136561
2XG65MF ML-136628
2XG85MF M
Resumo do conteúdo contido na página número 2
GRM SERIES GAS FRYERS IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT THE MAIN SHUTOFF
Resumo do conteúdo contido na página número 3
GRM SERIES GAS FRYERS TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY………………………………………. 2 INTRODUCTION…………………………………………………………… 4 GENERAL…………………………………………………………… 4 ORDERING PARTS………………………………………………… 4 FRYER CAPACITIES………………………………………………. 4 UNPACKING………………………………………………………… 4 INSTALLATION……………………………………………………………. 5 Clearances…………………………………………………....5 Location ………………..……………………………….…. 6 CODES AND STANDARDS……………………………………….. 6 ASSEMBLY …………..…………………………………………… 6 FLUE CONNECTION………………………………………
Resumo do conteúdo contido na página número 4
GRM SERIES GAS FRYERS INTRODUCTION GENERAL Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance. Before installing the fryer, thoroughly read this manual and carefully follow all instruction. This manual is applicable to model listed on the cover page. Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unles
Resumo do conteúdo contido na página número 5
GRM SERIES GAS FRYERS Check that the following have been included: Crumb Rack Basket Hanger Tank Brush Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer Batteries with the KleenScreen PLUS® Filtration System have casters installed from the factory. Drain Pipe Extension for freestanding fryers only. Twin Fry Baskets (2) Cleanout Rod Manual and Warranty Crumb Scoop Fryer Batteries with the KleenScreen PLUS® Filtration System • Filter P
Resumo do conteúdo contido na página número 6
GRM SERIES GAS FRYERS Minimum clearance from noncombustible construction: 0” from the sides of the fryer 0” from the back of the fryer Between the fryer and any open-top flame units: 16” (41 cm) Allow space for servicing and operation. Location Install fryer in an area with sufficient air supply for gas combustion at fryer burners. Do not obstruct the flow of combustion and ventilation air. Provide adequate clearance for air openings into the combustion chambe
Resumo do conteúdo contido na página número 7
GRM SERIES GAS FRYERS CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association 178 Rexdale Blvd., Etobicoke, Ontario Canada M9W 1R3. ASSEMBLY The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances, installing the fryer in an alcove, or by separate means such as adequate ties. FLUE CONNECTION Make the fl
Resumo do conteúdo contido na página número 8
GRM SERIES GAS FRYERS Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame. After piping has been checked for leaks, fully purge gas pipes to remove air. GAS PRESSURES (ALL MODELS): The gas pressure should be set at 4” W.C. (Water Column) (0.8 kPa) for natural gas and 10” W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an additional press
Resumo do conteúdo contido na página número 9
GRM SERIES GAS FRYERS In Australia, use only the caster supplied by the manufacturer for the fryer device. The fryer must be installed using a hose assembly restraining device to limit the movement of the appliance in accordance with AS1869. The fryer must be installed with a connector (not supplied by Vulcan) complying with the above codes. The fryer must be installed with restraining means to guard against transmission of strain to the connector. See illustration. The f
Resumo do conteúdo contido na página número 10
GRM SERIES GAS FRYERS BEFORE FIRST USE Cleaning New units are wiped down at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process. Before any food preparation, thoroughly wash the protective oil from all surface parts and the tank interior with hot soapy water to remove any film residue and dust or debris. Do not use chlorine or sulfate/sulfide cleaners. Wash any accessories shipped with unit. • Rinse fryer and acc
Resumo do conteúdo contido na página número 11
GRM SERIES GAS FRYERS LIGHTING THE PILOT A B A Thermostat Knob B Gas Control Handle 1. Open the door. 2. Turn the thermostat to OFF (see figure below, view A). The thermostat is located behind the door. 3. Push the gas control valve knob and turn to OFF. Wait 5 minutes for unburned gas to vent. 4. Push and turn gas control valve knob to the “L” in PILOT (see figure below, view B). 5. Wh
Resumo do conteúdo contido na página número 12
GRM SERIES GAS FRYERS TURNING ON THE FRYER Set the temperature knob to desired temperature. After the set temperature has been reached, the thermostat shuts off the gas flow to burners. The pilot remains lit. The burners will cycle on and off, maintaining the set temperature. TURNING OFF THE FRYER 1. Turn the thermostat OFF. 2. To keep the pilot lit, turn the gas valve to “L” in Pilot. 3. To shut off all gas to the system, including the pilot, turn the gas valve
Resumo do conteúdo contido na página número 13
GRM SERIES GAS FRYERS When frying doughnuts and fritters, turn product only once during frying. When cooking French fries or onion rings, shake the basket several times. Batter-covered foods should be dropped carefully, one by one, into shortening or basket. If you use the basket, first dip the basket into the shortening to reduce batter-build up on basket surfaces. When frying is completed, remove basket or product. Hang basket on rear hanger. Fry Basket Capa
Resumo do conteúdo contido na página número 14
GRM SERIES GAS FRYERS DAILY FILTERING Hot oil and hot parts can cause burns. Use care when operating, cleaning, and servicing the fryer. Filter shortening at least once a day. Refer to the instructions provided with your filtering equipment. A cold fryer will not drain properly. Always filter shortening between 250F and 350F. The shortening in the cold zone area will remain hard if the heat is only on for a few minutes. If necessary, use the clean-o
Resumo do conteúdo contido na página número 15
GRM SERIES GAS FRYERS Use a damp cloth with warm water and a mild soap or detergent. Do not use chlorine or sulfate/sulfide cleaners. Rinse thoroughly, and then polish with a soft dry cloth. Keep the fryer exterior clean and free of accumulated grease to prevent stubborn stains from forming. If regular cleaning is neglected, grease will be burned on and discolorations may form. Remove discolorations by washing with any detergent or soap and water. Use a self-
Resumo do conteúdo contido na página número 16
GRM SERIES GAS FRYERS KleenScreen PLUS® Filtration System Installation and Operational Manual For GRMF and 2XGMF Models 2GR45MF Shown GAS KleenScreen PLUS® Models: 2GR45MF ML-136417 2GR65MF ML-136418 2GR85MF ML-136419 3GR45MF ML-136420 3GR65MF ML-136421 3GR85MF ML-136422 4GR45MF ML-136423 4GR65MF ML-136661 4GR85MF ML-136664 2XG45MF
Resumo do conteúdo contido na página número 17
GRM SERIES GAS FRYERS Filtering Instructions for KleenScreen PLUS® Fryers General The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be drained and filtered at a time. Under no circumstances should both tanks be drained at the same time. Assembly • After unpacking, wash the filter pan, crumb basket and filter screen assembly. Make sure you remove the insert located inside the filter screen. Use di
Resumo do conteúdo contido na página número 18
GRM SERIES GAS FRYERS Fully assembled filter screen assembly: Fig. 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig. 3 Micro-Filtration Fabric Envelope Assembly: Same Suction Tube Fabric Envelope Insert (Different from Screen Assembly) Fabric Envelope Same Clip Same Knurled Knob Fig. 4 VULCAN-HART
Resumo do conteúdo contido na página número 19
GRM SERIES GAS FRYERS INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE). Step 1 Discard all oil from the filter vessel, (see pages 23 or 24). When the filter pan is empty, use a spatula and scrape off all debris left on the filter envelope and in the filter pan. Step 2 Unscrew “S” Tube from filter by tur
Resumo do conteúdo contido na página número 20
GRM SERIES GAS FRYERS Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. Never run water or boil out solution through filter and motor / pump. Doing so will void your fryer warranty. Solid shortening should NOT be used with GRM fryers. Me