for selecting an Eljer bathing product. Your new bath is shipped to you after careful inspection. The whirlpool
version is completely assembled with pump and circulatory system piping. All you need to finish the installation
are your selected fittings, electrical connections and support bedding material.
To ensure maximum performance
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS: Cover................................................................................................Page 1 Table of Contents..............................................................................Page 2 Safety Instructions Notice.................................................................Page 3 Installation, Framing and Post Installation Clean-Up Instructions.......................................................................Page 4 Typical Flange & Under Deck M
Resumo do conteúdo contido na página número 3
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS! ! WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision. ! WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting. ! WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within 60 inches (1524mm) of this unit
Resumo do conteúdo contido na página número 4
Installation and Framing Instructions Each bath arrives ready for installation, completely equipped with the pump and plumbing necessary for operation. However, a drain/overflow kit is required for each bath and it is not included. The variety of installations for this bath may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square. ! Remove the bath from the carton. Retain the shipping carton until satisfactor
Resumo do conteúdo contido na página número 5
INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access openin
Resumo do conteúdo contido na página número 6
TYPICAL FLANGE MOUNTING DETAIL SUGGESTED WHIRLPOOL / BATH TYPICAL INSTALLATION - INSTALLATION METHOD CORNER WOOD STUD STUDS WATERPROOF DRYWALL OR CEMENT BOARD TILE ROOFING NAIL 58-1/2" 58-1/2" SEALANT (1486mm) (1486mm) LEVELING 12" STRINGER (305mm) TUB 1 x 3 (25 x 76mm) WOOD STRINGER FULL LENGTH STEEL STEEL 19-1/2" STUD STUDS (495mm) 25" 25" (635mm) (635mm) WASHER WATERPROOF DRYWALL PUMP ACCESS PANEL OR CEMENT BOARD TILE SEALANT 4" (102mm) DRYWALL SCREW TUB UNLESS AN ACCESS OPENING OF
Resumo do conteúdo contido na página número 7
SPECIFICATIONS: L W J H C A SIDE VIEW END VIEW DRAIN / OVERFLOW B GENERAL SPECIFICATIONS FOR ELJER WHIRLPOOLS AND BATH TUBS Description Dimensions Drain / Height to Cut Out Rough-In Tub Edge to Weight with Product Gallon to L-W-H Overflow Underside Pier Recess Centerline Water / Floor Weight Overflow of Deck: C G x F E x D Overflow: J Loading L 60" (1524mm) 015-0005 A 15-1/4" C 17" 58-1/2" 60" 2-1/4" 418 lb. (190 kg)/ 98 lb. 40 W 32" (813mm) 5' x 32" (387mm) (432mm) (1486mm) (1524mm) (57mm) 31 l
Resumo do conteúdo contido na página número 8
ROUGH-IN REFERENCES CYPRESS MODEL 015-0005 60" (1524mm) 0/I 16" (406mm) 40-1/2" (1029mm) 32" 19-1/2" (813mm) (495mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS 10-1/4" (260mm) MADISON MODEL 015-0015 60" (1524mm) 0/I 16" (406mm) 40-1/2" 32" (1029mm) (813mm) 19-1/2" (495mm) 9" x 14" (229 x 356mm) PROVIDE ACCESS FLOOR CUTOUT TO PUMP SERVING ON ALL INSTALLATIONS 10-1/4" (260mm) 754764-100 Rev. A 8
Resumo do conteúdo contido na página número 9
ROUGH-IN REFERENCES CANTERBURY MODEL 015-0026 60" (1524mm) 18" (457mm) 44-1/2" 36" (1130mm) (914mm) 24-1/2" (622mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP 8-1/4" (209mm) TRIANGLE MODEL 015-0066 35-1/2" (902mm) 60" (1524mm) PROVIDE ACCESS TO PUMP SERVING ON 35-1/2" ALL INSTALLATIONS (902mm) 46" (1168mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT 25-1/4" 0/I 10-1/2" (641mm) (267mm) 48-5/8" (1235mm) 754764-100 Rev. A 9
Resumo do conteúdo contido na página número 10
ROUGH-IN REFERENCES EMBLEM MODEL 015-0076 EMBLEM TOTAL MASSAGE MODEL 015-0077 72" (1829mm) 0/I 18" (457mm) 51-1/2" (1308mm) 36" 21-1/2" (914mm) (546mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS 10-1/2" (267mm) PATRIOT MODEL 015-0309/0305 (Right hand version shown) 60" (1524mm) 16" (406mm) 42" 32" (1067mm) (813mm) 18" (457mm) 9" x 14" (229 x 356mm) FLOOR CUTOUT PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS 0/I 9-1/2" (241mm) 754764-100 Rev. A
Resumo do conteúdo contido na página número 11
ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Grounding is required. The unit should be installed by a licensed electrician and grounded. 3. Ins
Resumo do conteúdo contido na página número 12
ELECTRICAL INSTALLATION INSTRUCTIONS (continued) TOTAL MASSAGE WHIRLPOOLS The whirlpool pump and blower should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT IS REQUIRED IF THE OPTIONAL HEATER IS INSTALLED (SEE INSTALLATION IN
Resumo do conteúdo contido na página número 13
OPERATING INSTRUCTIONS 1. Fill the bath to at least 3 inches above the jets before activating the pump. 2. The pump is activated by an on/off switch. Each depression of the button switches the power either on or off. Do not repeatedly depress the switch in rapid order if you do not see the whirlpool function right away, as it may take a few seconds before you can see it fully operating. 3. If any factory installed fittings are removed do not operate the unit. A safety hazard may occur.
Resumo do conteúdo contido na página número 14
Your Eljer whirlpool is designed to give you many years of pleasure with reasonable care and maintenance. Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other Eljer fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its lasting luster with proper care and maintenance. CLEANING AND MAINTENANCE: � Always fill the tub with temperate water. Excessively hot water (greater than 130˚ F) may cause surfa
Resumo do conteúdo contido na página número 15
AS AMERICA, INC. LIMITED LIFETIME WARRANTY FOR ELJER PREMIERE SERIES ACRYLIC TUBS AS America, Inc. (“American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this tub or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser. This limited warranty does not apply to commercial installations. The warrant