Resumo do conteúdo contido na página número 1
864 HH
AAA
Fireplace
AAA AAA AA
Featuring the
AAA AAA AA AAA
AAA AAA AA AAA AAA
Burner
AAA AAA AAAAAAAAAAAA AA AAA AAA
Drywall
AAA AAA AAAAAAAAAAAA AA AAA AAA
Tested and Listed by
AAA AAA AAAAAAAAAAAA AA AAA AAA
AAA AAAAA AAAAAAAAAAAA AA AAA AAA A
OMNI-Test Laboratories, Inc.
Beaverton, Oregon
AAA AAAA AA AAA AAA
Report # 028-F-59b-5
ANSI Z21.88b-2003
AA AAAAAA AAA AAA
• Built-In Direct Vent Fireplace
AA AA AAA
• Natural Gas or Propane
• Residential or Mobile Home
WARNING: If the information i
Resumo do conteúdo contido na página número 2
2 Introduction Overview This manual details the installation requirements for the 864 HH (Home Heater) fireplace. For operating and maintenance instructions, refer to the 864 HH Owner's Manual (part # 100-01181). Listing Details This appliance was listed by OMNI-Test Laboratories, Inc. to ANSI Z21.88 - report # 028- F-59b-5. The listing label is attached to the appliance near the gas control valve. A copy is shown to the right. IAS (ICBO) Approval This appliance was listed by OMNI-Test Laborat
Resumo do conteúdo contido na página número 3
Table of Contents 3 Introduction Installation (continued) Overview.................................................................2 Hearth Requirements ............................................... 32 Listing Details..........................................................2 Facing Requirements ............................................... 33 Drywall Installation ................................................33 Facing Overview ...................................................34 Safety P
Resumo do conteúdo contido na página número 4
4 Safety Precautions Safety Warnings: • Failure to follow all of the requirements may result in property damage, bodily injury, or even death. • This unit must be installed by a qualified installer to prevent the possibility of an explosion. • This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI Z223.1 and NFPA 54(88). • In Manufactured or Mobile Homes must confirm with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR
Resumo do conteúdo contido na página número 5
Safety Precautions 5 Safety Warnings (continued): • Allow the heater to cool before carrying out any maintenance or cleaning. • Operate the heater according to the instructions included in this manual. • If the main burners do not start correctly turn the gas off at the gas control valve and call your dealer for service. • The pilot flame must contact the thermopile and thermocouple. If it does not, turn the gas control valve to "OFF" and call your dealer. • This unit is not for use with solid
Resumo do conteúdo contido na página número 6
6 Features and Specifications Installation Options • Residential or Mobile Home • Raised or Floor Placement • Straight or Corner Placement • Internal or External Chase • Flush or Recessed Face • Horizontal or Vertical Vent • Bedroom Approved Heating Specifications Natural Gas Propane Approximate Heating Capacity (in square feet)* 1,200 to 2,250 1,200 to 2,250 Maximum BTU Input Per Hour 40,000 39,000 Steady State Efficiency** (with blowers on) Up to 80 % Up to 81 % * Heating capacity will vary wi
Resumo do conteúdo contido na página número 7
Installation (for qualified installers only) 7 Packing List • Wall Switch with Wire (see page 20 for details) • Propane Conversion Kit • Firestop (sku 93006094) • Log Set (9 piece) • Grate Additional Items Required • FIREBACKS ARE REQUIRED – See page 47. (sku 98500662, 98500663, 98500664, or 98500665) • Direct Vent • Gas Line Equipment (shutoff valve, pipe, etc.) • Electrical Equipment (min. 14 gauge, grounded line) • Grill Installation Overview • All requirements below must be met. Top Ven
Resumo do conteúdo contido na página número 8
8 Installation (for qualified installers only) Massachusetts Requirements NOTE : The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent ter
Resumo do conteúdo contido na página número 9
Installation (for qualified installers only) 9 Top Vent or Rear Vent Configuration This appliance is shipped in the rear vent configuration. To change to the top vent configuration, follow the directions below. NOTE: the vent configuration affects several aspects of installation (framing, maximum vent rise, maximum vent run). When reviewing the installation requirements make sure to pay attention to the type of configuration being used. Converting the Fireplace to Top Vent Remove the 4 screws
Resumo do conteúdo contido na página número 10
10 Installation (for qualified installers only) Converting the NOTE: Use a magnetic- Fireplace to Top Vent tipped nutdriver on these (continued) screws - take care to prevent the screws from falling into the fireplace. Remove the 12 screws securing the flue assembly. Rotate the flue assembly so the flue points upwards. Secure using the twelve screws removed earlier. DO NOT OVER- TIGHTEN THE SCREWS. Attach the intake cover plate with the screws removed earlier. Attach the cover pla
Resumo do conteúdo contido na página número 11
Installation (for qualified installers only) 11 Fireplace Placement Requirements • The fireplace requires a 1/2" clearance from the angled sides and back of the fireplace to the framing members. No material (insulation, framing, etc.) may be placed into this area. • Fireplace must be installed on a level surface capable of supporting the fireplace and vent • Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet) • This heater may be placed in a bedroom
Resumo do conteúdo contido na página número 12
12 Installation (for qualified installers only) Minimum Framing Dimensions - Rear Vent Configuration Included Firestop (required) HINT: place the fireplace so the center Part # 93006094 line is at least 5" from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Vent Clearances (8" dia. Vent): 1" to the sides, 1" below, and 3" above the vent to combustibles. Center of Rear Vent AAAAA A AAAAAAAAAA A Minimum 49” Fireplace AA A
Resumo do conteúdo contido na página número 13
Installation (for qualified installers only) 13 Minimum Framing Dimensions - Top Vent Configuration Minimum 49” Fireplace Enclosure Height Route the electrical line to a position to the left rear of the fireplace. 38-1/2" 41-1/4" 20" The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. © Travis Industries 4070201 100-01182_002
Resumo do conteúdo contido na página número 14
14 Installation (for qualified installers only) Nailing Brackets There are four nailing brackets on the front of the fireplace. Follow the directions below to prepare the nailing brackets. Once in place, nail or screw the WARNING: Make sure the nailing brackets to the framing. fireplace is square and plumb when placed in the framing. Measured corner-to-corner, the NOTE: Additional nailing fireplace should be square brackets are provided along (approx. 54-7/8” for each the base
Resumo do conteúdo contido na página número 15
Installation (for qualified installers only) 15 Corner Installations - Rear Vent Configuration A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Travis Firestop Minimum 1/2" Clearance Minimum 1" Clearance (sku 93006094) AAAAAAAAAAAAA A AAAAAAAAAAAAA 7-1/2" Approximate (varies due to vent A A installation) A A A A A AAAAAAAAAAAAA A AAAAAAAAAAAAA NOTE: Most installations use: A AAAAAAAAAAAAA A AAAAAAAAAAAAA 6" Section for
Resumo do conteúdo contido na página número 16
16 Installation (for qualified installers only) Corner Installations - Top Vent Configuration A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Minimum 1/2" Clearance AAAAAAAAAAAAA A A AA AAAAAAAAAAAA A AA A AA 15-1/2" A AA A AA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA 48" Min. A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA AA AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAA
Resumo do conteúdo contido na página número 17
Installation (for qualified installers only) 17 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNING: THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS. OTHER MASSACHUSETTS CODE REQUIREMENTS: • Flexible connector must not be longer than 36 inches. • Shutoff valve must be a “T” handle gas cock. • Only direct vent sealed combustion products are approved for bedrooms or bathrooms. • Fireplace dampers must be removed
Resumo do conteúdo contido na página número 18
18 Installation (for qualified installers only) Gas Line Location Left Side Gas Inlet (preferred) A 12" flex tube and shutoff valve is included A 2" high by 3" wide opening is located with the fireplace. The behind the gas inlet cover plate (it is 2" shutoff valve accepts a above the base of the fireplace). 1/2"MPT. The Gas Inlet is 3/8" FPT 6-3/4" You may remove this cover plate to install the gas line. The cover plate has a 7/8" diameter hole (covered with a push plug). By rotatin
Resumo do conteúdo contido na página número 19
Installation (for qualified installers only) 19 Electrical Connection (required) • The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and must meet all local codes. • Make sure the household breaker is shut off prior to working on any electrical lines. • The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987) • The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps) Caut
Resumo do conteúdo contido na página número 20
20 Installation (for qualified installers only) Wall Switch or Thermostat Installation Wiring Diagram (Millivolt System) Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch must be installed by a qualified installer. The included wall switch may be installed following the directions below. An optional thermostat may also be installed. It is attached to the gas control valve in the same manner. Caution: Label all wires prior to disconnection when