Resumo do conteúdo contido na página número 1
Portable Generator
Operator’s Manual
This generator is rated in accordance with CSA (Canadian Standards
Association) standard C22.2 No. 100-04 (motors and generators).
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WISCONSIN, U.S.A.
Manual No. 209443GS Revision - (04/02/2009)
Resumo do conteúdo contido na página número 2
Thank you for purchasing this quality-built Briggs & Stratton generator. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service. This manual contains safety information to make you aware of the hazards and risks associated with generators and how to avoid them. This generator is designed and intended only for supplyin
Resumo do conteúdo contido na página número 3
Table of Contents Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Important Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Unpack Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Resumo do conteúdo contido na página número 4
Safety Symbols and Meanings Operator Safety Equipment Description Read this manual carefully and become familiar with your generator. Know its applications, its Toxic Fumes Kickback Electrical Shock limitations and any hazards involved. The generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, Fire Explosion Operator’s Manual tools and motor loads. The generator’s re
Resumo do conteúdo contido na página número 5
WARNING Generator produces hazardous voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy. • When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility. • Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work. • DO NOT touch bare wires or receptacles.
Resumo do conteúdo contido na página número 6
WARNING Contact with muffler area can result in CAUTION Excessively high operating speeds increase serious burns. risk of injury and damage to generator. Exhaust heat/gases can ignite Excessively low speeds impose a heavy load. combustibles, structures or damage • DO NOT tamper with governed speed. Generator supplies fuel tank causing a fire. correct rated frequency and voltage when running at governed • DO NOT touch hot parts and AVOID hot exhaust gases. speed. • Allow equipment to cool be
Resumo do conteúdo contido na página número 7
You will need the following tools to install these components: Assembly • 10 mm and 13 mm wrenches Read entire operator’s manual before you attempt • Socket wrench with 10 mm and 13 mm sockets to assemble or operate your new generator. • Adjustable wrenches (2) Your generator requires some assembly and is ready for use Install the wheel kit as follows: after it has been properly serviced with the recommended oil and fuel. 1. Tip generator so that engine end is up. If you have any problems with t
Resumo do conteúdo contido na página número 8
Add Engine Oil WARNING Fuel and its vapors are extremely 1. Place generator on a flat, level surface. flammable and explosive. Fire or explosion can cause severe burns 2. Clean area around oil fill and remove yellow oil fill cap. or death. 3. Using oil funnel (optional), slowly pour contents of WHEN ADDING FUEL provided oil bottle into oil fill opening. • Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank. NOTICE Impro
Resumo do conteúdo contido na página número 9
System Ground Generator Location The generator has a system ground that connects the Clearances and Air Movement generator frame components to the ground terminals on the WARNING Exhaust heat/gases can ignite AC output receptacles. The system ground is connected to combustibles, structures or damage fuel tank the AC neutral wire (the neutral is bonded to the generator causing a fire. frame). • Keep at least 5 ft. (152 cm) clearance on all sides of generator Special Requirements including overh
Resumo do conteúdo contido na página número 10
Features and Controls Read this operator’s manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. N M A L B K C J D H E F G A - Spark Arrester Muffler — Exhaust muffler lowers engine K - 120/240 Volt AC, 20 Amp Locking Receptacle — May noise and is equipped with a spark arrester screen. be used to supply electrical power for the o
Resumo do conteúdo contido na página número 11
This receptacle powers 120/240 Volt AC, 60 Hz, single phase Cord Sets and Receptacles loads requiring up to 3,250 watts of power (3.25 kW) at Use only high quality, well-insulated, grounded extension 13.5 Amps for 240 Volts or two independent 120 Volt loads cords with the generator’s 120 Volt duplex receptacle. at 13.5 Amps each. The outlet is protected by a double pole Inspect extension cords before each use. circuit breaker. Check the ratings of all extension cords before you use them. Extensi
Resumo do conteúdo contido na página número 12
Operation WARNING Starter cord kickback (rapid retraction) can result in bodily injury. Kickback will pull hand and arm toward engine faster than you can let go. Starting the Engine Broken bones, fractures, bruises, or sprains Disconnect all electrical loads from the generator. Use the could result. following start instructions: • When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback. 1. Make sure unit is on a level surface. • NEVER start or st
Resumo do conteúdo contido na página número 13
Connecting Electrical Loads Stopping the Engine 1. Let engine stabilize and warm up for a few minutes 1. Turn OFF and unplug all electrical loads from generator after starting. panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON. 2. Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads. 2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator. NOTE: 3. Push engine
Resumo do conteúdo contido na página número 14
NEVER add more loads than the generator capacity. Take Don’t Overload Generator special care to consider surge loads in generator capacity, as Capacity described above. You must make sure your generator can supply enough Wattage Reference Guide rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: Rated* Additional Tool or Appliance (Running) Surge 1. Select the items you will power at the same time. Watts (Starting) 2. Total the rat
Resumo do conteúdo contido na página número 15
Generator Maintenance Maintenance Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry Maintenance Schedule environment where it will not be exposed to excessive dust, Follow the hourly or calendar intervals, whichever occurs dirt, moisture, or any corrosive vapors. Cooling air slots in first. More frequent service is required when operating in the generator must not become clogged with snow, leaves, adverse conditions noted below. or any ot
Resumo do conteúdo contido na página número 16
3. Wash sediment cup, o-ring, retaining ring, and screen 3. Verify oil is at the point of overflowing at oil fill opening. in a nonflammable solvent. Dry them thoroughly. 4. Replace and tighten oil fill cap. 4. Place screen, retaining ring, and o-ring into fuel valve. Install sediment cup and tighten securely. Adding Engine Oil 5. Move fuel valve to “On” position, and check for leaks. 1. Make sure generator is on a level surface. Replace o-ring if there is any leakage. 2. Check oil level as desc
Resumo do conteúdo contido na página número 17
Service Air Cleaner Inspect Muffler and Spark Arrester Your engine will not run properly and may be damaged if Inspect the muffler for cracks, corrosion, or other damage. you run it with a dirty air cleaner. Replace more often if Remove the spark arrester, if equipped, and inspect for operating under dirty or dusty conditions. damage or carbon blockage. If replacement parts are To service the air cleaner, follow these steps: required, make sure to use only original equipment replacement parts. 1
Resumo do conteúdo contido na página número 18
Air Cooling System There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine Over time debris may accumulate in cylinder cooling fins and for 2 minutes to circulate the stabilizer throughout the fuel cannot be observed without partial engine disassembly. For this reason, we recommend you have an authorized Briggs & system. The engine and fuel can then be stored up to Stratton service dealer clean the cooling system (H) per 24 month
Resumo do conteúdo contido na página número 19
Troubleshooting Problem Cause Correction 1. One of the circuit breakers is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no AC 3. Poor connection or defective cord set. 3. Check and repair. output is available. 4. Connected device is bad. 4. Connect another device that is in good condition. 1. Short circuit in a connected load. 1. Disconnect shorted electrical load. 2. Engine speed is too slow. 2. Contact authorized service
Resumo do conteúdo contido na página número 20
Briggs & Stratton Emissions Control Warranty Provisions Warranties The following are specific provisions relative to your Emissions Control Warranty Coverage. It is in addition to the California, U.S. EPA, and Briggs & Stratton B&S engine warranty for non-regulated engines found in the Corporation Emissions Control Warranty Operator’s Manual. Statement 1. Warranted Emissions Parts Coverage under this warranty extends only to the parts Your Warranty Rights And Obligations listed below (the emissi