Resumo do conteúdo contido na página número 1
Sipura Technology, Inc.
SPA-2000 User Guide
December 2003
Sipura SPA-2000 User Guide v1.0.3.doc
© 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2)
1
Resumo do conteúdo contido na página número 2
Disclaimer – Please Read: This document contains implementation examples and techniques using Sipura Technology, Inc. and, in some instances, other company’s technology and products and is a recommendation only and does not constitute any legal arrangement between Sipura Technology, Inc. and the reader, either written or implied. The conclusions reached and recommendations and statements made are based on generic network, service and application requirements and should be
Resumo do conteúdo contido na página número 3
Sipura Technology, Inc. SPA-2000 User Guide Table of Contents 1. Product Description....................................................................................................................................................4 1.1. SPA-2000 Hardware Overview ........................................................................................................................4 1.1.1. Status LED Description:..................................................................
Resumo do conteúdo contido na página número 4
1. Product Description This guide describes basic administration and use of the Sipura Technology SPA-2000 phone adapter – an intelligent low-density Voice over IP (VoIP) gateway. The SPA-2000 enables carrier class residential and business IP Telephony services delivered over broadband or high-speed Internet connections. By intelligent we mean the SPA-2000 maintains the states of all the calls it terminates. It is capable of making proper decisions in reaction to user input events (s
Resumo do conteúdo contido na página número 5
This LED indicates status via the following behaviors: ON – LED remains solid on OFF – LED remains solid off LONG (Long On) – 3.0s on, 1s off continuously FAST – 0.125s on, 0.125s off continuously SLOW – 0.5s on, 0.5s off continuously VSLO (Very Slow) – 1.0s on, 1.0s off continuously HB (Heart Beat) – 0.125s on, 0.125s off, 0.125s on, 1s off continuously 3. One Ethernet 10baseT RJ-45 Jack Interface ( Figure , above): This interface accepts a standard or crossover Ethernet cable w
Resumo do conteúdo contido na página número 6
Unknown DHCP Error SLOW Silent Note: The Link LED will blink on transmit and receive (TX/RX) of packets. The LED will display solid off if no link is available. The LED will display solid on if link is up but no TX/RX activity is present. Important Warning: Do not disrupt the power to the SPA-2000 while the Status LED is blinking FAST. 2. Installation Overview Please check to make sure that you have the following package contents: 1. Sipura Phone Adapter Unit 2. Ethernet Cable
Resumo do conteúdo contido na página número 7
Alternatively, an individual SPA-2000 can be directed to perform an upgrade to a specific firmware load via its built-in web server interface. Firmware upgrades are attempted only when the SPA-2000 is idle, since they trigger a software reboot. Firmware Upgrade via PC Utility Program: From time to time, Sipura Technology will make available a PC executable file that will facilitate the upgrade of a SPA-2000. In order to upgrade a device via this method, the end user must have ad
Resumo do conteúdo contido na página número 8
o To input: W, X, Y, Z, w, x, y, z -- press ‘9’ o To input all other characters in the administrator password, press ‘0’ Note: This translation convention only applies to the password input. For example: to input password “test#@1234” by phone keypad, you need to press the following sequence of digits: 8378001234. 2. After entering a value, press the # (pound) key to indicate end of input. o To Save value, press ‘1’ o To Review the value, press ‘2’ o To Re-enter the value, press
Resumo do conteúdo contido na página número 9
Enable/Disable DHCP 101 Enter 1 to enable Enter 0 to disable Check IP Address 110 None IVR will announce the current IP address of SPA. Set Static IP Address 111 Enter IP address DHCP must be “Disabled” using numbers on otherwise you will hear, the telephone key “Invalid Option,” if you try pad. Use the * to set this value. (star) key when entering a decimal point. Check Network Mask 120 None IVR will announce the current network mask of SPA. Set Network Mask 121 Enter valu
Resumo do conteúdo contido na página número 10
up. Unit will reboot and all ALL SETTINGS WILL BE LOST! configuration parameters will be reset to factory default values. Note: If the Administrator password is not set, the items marked with “Requires Password” will not require a password. 3.3. SPA Web Interface The SPA provides a built-in web server. Convenient configuration and administration can be performed through an integral web interface. 3.3.1. Web Interface Conventions The SPA uses the following conventions with t
Resumo do conteúdo contido na página número 11
profile parameters. The parameter group that the User can access is specified by the Administrator, which can only be done through provisioning the SPA-2000 via the TFTP process. To access the Administrator level privilege, use the following URL: http://IP_Address_Of_SPA/admin/. If the password has been set for Administrator, the browser will prompt for Administrator authentication. The username for Administrator is “admin” and cannot be changed. To access the User level privilege, us
Resumo do conteúdo contido na página número 12
3.3.4. SPA-2000 Web Page Configuration Default Values The following figures depict the default values and web page locations of the SPA-2000 web administration and configuration pages. The SPA-2000 Administrator Log-in, Advanced screen settings are shown below. Figure 1 – SPA-2000 Information Web Page (Advanced Admin View) © 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2) 12
Resumo do conteúdo contido na página número 13
Figure 2 – SPA-2000 System Configuration Web Page (Advanced Admin View) © 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2) 13
Resumo do conteúdo contido na página número 14
Figure 3 – SPA-2000 SIP Configuration Web Page (Advanced Admin View) © 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2) 14
Resumo do conteúdo contido na página número 15
Figure 4 – SPA-2000 Provisioning Configuration Web Page (Advanced Admin View) © 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2) 15
Resumo do conteúdo contido na página número 16
Figure 5 – SPA-2000 Regional Configuration Web Page (Advanced Admin View) © 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2) 16
Resumo do conteúdo contido na página número 17
Figure 6 – SPA-2000 Line 1 Configuration Web Page (Line 2 Is Identical) © 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2) 17
Resumo do conteúdo contido na página número 18
Figure 7 – SPA-2000 User 1 Configuration Web Page (User 2 Is Identical) © 2003 Sipura Technology, Inc Proprietary (See Copyright Notice on Page 2) 18
Resumo do conteúdo contido na página número 19
3.4. Configuration Parameters 3.4.1. System Parameters System Configuration Parameter Name Description Default Admin Password The password for administrator User Password The password for User Enable Web Server Enable/disable web server of SPA Yes This feature should only be used on firmware version 1.0.9 or later. Network Configuration Parameter Name Description Default DHCP Enable/Disable DHCP Yes Host Name Host Name of SPA Domain Name The network domain of SPA Static IP St
Resumo do conteúdo contido na página número 20
Resync On Reset Resyncs configuration profile from configuration server Yes whenever the SPA-2000 resets. Resync Random Spread interval for resync requests 2 Delay Resync Periodic Resyncs configuration profile periodically after reset. 3600 Resync Error Retry interval following resync failure 3600 Retry Delay Resync From SIP Enables resync of configuration profile from a SIP command. Yes Profile Rule Configuration profile URL script. /spa.cfg Log Resync Syslog message generated whe