Resumo do conteúdo contido na página número 1
Order No. RAC0504012C2
Air Conditioner
CS-HE9DKE CU-HE9DKE
CS-HE12DKE CU-HE12DKE
CONTENTS
Page Page
1 Features 2 7.2. OutdoorUnit 15
2 Functions 3 8 ElectronicCircuitDiagram 16
2.1. RemoteControl 3 8.1. IndoorUnit/RemoteController 16
2.2. IndoorUnit 4 8.2. OutdoorUnit 18
2.3. Outdoorunit 5 9 OperationDetails 20
3 ProductSpecifications 6 9.1. BasicFunction 20
4 Dimensions 10 9.2. IndoorPowerRelayControl 21
4.1. IndoorUnit/RemoteControl 10 9.3. RoomTemperatureControl(CompressorControl) 22
Resumo do conteúdo contido na página número 2
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 9.8. AutomaticOperation 31 12.2. Tools For Installing/Servicing Refrigerant Piping 56 9.9. SleepTimerOperation 32 12.3. Refrigerant Piping Work 60 9.10. Timer Operation 32 12.4. Installation, Transferring, Servicing 63 9.11. Auto Restart Control 32 13 Servicing Information 67 9.12. Ionizer Operation 33 13.1. About Lead Solder (PbF) 67 9.13. Oxygen Enrich Operation 34 13.2. Troubleshooting 68 9.14. Deice Control 36 13.3. Disassembly of
Resumo do conteúdo contido na página número 3
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 2 Functions 2.1. RemoteControl 3
Resumo do conteúdo contido na página número 4
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 2.2. IndoorUnit 4
Resumo do conteúdo contido na página número 5
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 2.3. Outdoorunit 5
Resumo do conteúdo contido na página número 6
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 3 ProductSpecifications Unit CS-HE9DKE CU-HE9DKE Cooling Capacity kW 2.60 (0.60 - 3.00) kcal/h 2,240 (520 - 2,580) BTU/h 8,870 (2,050 - 10,200) Heating Capacity kW 3.60 (0.60 - 6.50) kcal/h 3,100 (520 - 5,590) BTU/h 12,300 (2,050 - 22,080) Moisture Removal l/h 1.5 Pint/h (3.2) Power Source Phase Single V 230/240 Cycle 50 Airflow Method OUTLET SIDE VIEW TOP VIEW INTAKE 3 Air Volume Indoor Air (Lo) m /min (cfm) Cooling; 5.2 (180) — Heating; 6.3 (220) 3 I
Resumo do conteúdo contido na página número 7
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE Unit CS-HE9DKE CU-HE9DKE Drain Inner diameter mm 16 — Hose Length m 0.65 — Power Cord Length 1.8 m — 2 Number of core-wire 3-core wires × 1.0 mm — Dimensions Height inch (mm) 11 - 23/32 (298) 21 - 1/4 (540) Width inch (mm) 34 - 8/32 (870) 30 - 23/32 (780) Depth inch (mm) 7 - 27/32 (199) 11 - 3/8 (289) Net Weight lb (kg) 24 (11) 79 (36) Compressor Type — Involute scroll Motor Type — Brushless (4-poles) Rated Output W — 750 Air Circulation Type Cross-flo
Resumo do conteúdo contido na página número 8
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE Unit CS-HE12DKE CU-HE12DKE Cooling Capacity kW 3.50 (0.60 - 4.00) kcal/h 3,010 (520 - 3,440) BTU/h 11,900 (2,050 - 13,600) Heating Capacity kW 4.80 (0.60 - 7.70) kcal/h 4,130 (520 - 6,620) BTU/h 16,400 (2,050 - 26,100) Moisture Removal l/h 2.0 Pint/h (4.2) Power Source Phase Single V 230/240 Cycle 50 Airflow Method OUTLET SIDE VIEW TOP VIEW INTAKE 3 Air Volume Indoor Air (Lo) m /min (cfm) Cooling; 6.2 (220) — Heating; 7.8 (280) 3 Indoor Air (Me) m /min
Resumo do conteúdo contido na página número 9
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE Unit CS-HE12DKE CU-HE12DKE Dimensions Height inch (mm) 11 - 23/32 (298) 21 - 1/4 (540) Width inch (mm) 34 - 8/32 (870) 30 - 23/32 (780) Depth inch (mm) 7 - 27/32 (199) 11 - 3/8 (289) Net Weight lb (kg) 24 (11) 82 (37) Compressor Type — Involute scroll Motor Type — Brushless (4-poles) Rated Output W — 1,100 Air Circulation Type Cross-flow Fan Propeller Fan Material AS + Glass Fiber 20% P.P Motor Type Transistor (8-poles) Induction (8-poles) Input W — —
Resumo do conteúdo contido na página número 10
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 4 Dimensions 4.1. IndoorUnit/RemoteControl 10
Resumo do conteúdo contido na página número 11
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 4.2. OutdoorUnit 11
Resumo do conteúdo contido na página número 12
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 5 RefrigerationCycleDiagram 12
Resumo do conteúdo contido na página número 13
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 6 BlockDiagram 13
Resumo do conteúdo contido na página número 14
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 7 WiringDiagram 7.1. IndoorUnit 14
Resumo do conteúdo contido na página número 15
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 7.2. OutdoorUnit 15
Resumo do conteúdo contido na página número 16
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 8 ElectronicCircuitDiagram 8.1. IndoorUnit/RemoteController 16
Resumo do conteúdo contido na página número 17
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 17
Resumo do conteúdo contido na página número 18
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 8.2. OutdoorUnit 18
Resumo do conteúdo contido na página número 19
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 19
Resumo do conteúdo contido na página número 20
CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 9 OperationDetails 9.1. BasicFunction Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting. The compressor at outdoor unit is operating following t