Resumo do conteúdo contido na página número 1
ETA-C15D
Power Conditioner
ETA-C15D
Power Conditioner
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 1 – ETAsys.com
Specifications are subject to change without notice.
Resumo do conteúdo contido na página número 2
ETA-C15D Power Conditioner TABLE OF CONTENTS Important Safety Instructions ................................................................................................................. 3 Introduction ........................................................................................................................................... 5 Key Features .......................................................................................................................................
Resumo do conteúdo contido na página número 3
ETA-C15D Power Conditioner IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in
Resumo do conteúdo contido na página número 4
ETA-C15D Power Conditioner WARNING – WHEN THE DEVICE IS IN USE • T o prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to ETA Systems. • Should any of the following irregularities occur during use, immediately switch off the power , disconnect the power cord from the AC outlet and contact ETA Systems. Do not to attempt to continue operation with the product as this may cause fire or electric shock: • Smoke
Resumo do conteúdo contido na página número 5
ETA-C15D Power Conditioner INTRODUCTION Thank you for purchasing the ETA Systems ETA-C15D AC Power Conditioner. The ETA-C15D has been designed to meet most installation requirements for AC power distribution and equipment power protection. The 15A compact 1RU unit AC Mains Voltage can be monitored via the front panel from the precision Digital Volt Meter. To light your rack, the ETA-C15D has incorporated a front panel pull-out dimmable LED tube light. The rear of the rack can be illuminated
Resumo do conteúdo contido na página número 6
ETA-C15D Power Conditioner KEY FEATURES • 10 T otal Outlets Are Provided • 8 Rear Panel Outlets • 2 Front Panel and 1 Rear Panel Unswitched Convenience Outlets • RFI Noise Filtering to Reduce Radio Frequency Interference • EMI T o Reduce Electromagnetic Interference • Dual Clamping Spike & Surge Suppression, DCS Circuitry • Front Panel Digital AC Mains V oltmeter • LED Indication of Reversed “Live” and “Ne
Resumo do conteúdo contido na página número 7
ETA-C15D Power Conditioner FRONT PANEL FEATURES 8 9 10 11 12 6 7 6. AC Mains Function Display 7. AC Mains Voltage Display – This display will illuminate when the AC Mains power cord is plugged into an AC source. Note: the display has a 1.5% tolerance. 8. Power On LED – Will illuminate green when the AC Mains Power Switch is in the ON Position. 9. AC Mains Wiring Polarity Fault Indicator – The red LED will illuminate if the AC Mains Power
Resumo do conteúdo contido na página número 8
ETA-C15D Power Conditioner REAR PANEL FEATURES 6 5 2 3 4 1 1. AC Mains Input – Connect the 9' (3m) power cord to a 15A 120V AC outlet to provide power to the ET A-C15D. 2. AC Filtered Outlets – The five AC outlets are “Live” when the power switch is activated. These outlets are recommended for products such as Computers, Modems, Routers, DSP Processors, Cable/SAT, DVD, or CRT TVs. These outlets have a special filter circuit that is optimized to
Resumo do conteúdo contido na página número 9
ETA-C15D Power Conditioner AC POWER CORD RETAINER SYSTEM Your ETA Systems product comes with an AC Mains Power Cord Retainer System. This system prevents the power cord from being removed without the use of a screwdriver. Follow these steps for installation. Note: Installation of this product must be done by a certified electrician for a permanently connected apparatus provided neither with an all-pole mains switch nor an all-pole circuit breaker. A readily accessible disconnect device shall
Resumo do conteúdo contido na página número 10
ETA-C15D Power Conditioner TROUBLESHOOTING GUIDE Issue: Wiring Fault LED is illuminated. Possible Cause: AC Mains outlet is wired incorrectly. Action Needed: Contact a certified electrician to inspect the building's wiring. Issue: No power to the AC outlets. Possible Cause: Circuit breaker has tripped due to excessive load. Action Needed: Remove one piece of equipment from the ETA-C15D, and push the breaker reset tab located on the front panel. Note: W
Resumo do conteúdo contido na página número 11
ETA-C15D Power Conditioner ETA-C15D SPECIFICATIONS T ype Power Conditioner & Suppressor Load Rating 15A Safety Listing ETL (UL 60065 Standard) Front Panel AC Outlets 2 Unswitched Lights 1 Pull Out LED with Dimmer Switch Activation Switch Rocker Circuit Breaker 15A Resettable AC Mains Voltmeter Thre Digits, Digital Indicators AC Power On, Abnormal V oltage, AC Fault, Breaker Open, Wiring Fault Rear Panel AC Outlets 8 Total, 6 Filtered, 1 High Power Non-Filtered, 1 Unswitched L
Resumo do conteúdo contido na página número 12
ETA-C15D Power Conditioner LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty. ETA Systems will solely at its discretion, replace at no charge or repair free o