Resumo do conteúdo contido na página número 1
E
V
O
T
S
C
S
O
E
M
T
Owner’s Operation and Instruction Manual
MODELS: 2000, 2500
SAFETY TESTED TO UL 1482
US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE
WASHINGTON STATE APPROVED
MOBILE HOME APPROVED (US ONLY)
CAUTION! SAFETY NOTICE:
Read All Instructions Carefully If this heater is not properly installed, a house fire
Before Starting The Installation may result. For your safety, follow the installation
or Operating This Heater. instructions. Contact local building or fir
Resumo do conteúdo contido na página número 2
CONGRATULATIONS! You’ve purchased a heater from North America’s oldest manufacturer of wood burning products. By heating with wood you’re helping to CONSERVE ENERGY! Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one tree each year. Future generations will thank you. The instructions pertaining to the installation of your wood stove comply with UL-1482 standards. Combustible : Model Wood Colors : Metallic Black Flue Pipe Diameter : 6”
Resumo do conteúdo contido na página número 3
Tools and Materials Needed For Installation You will need a drill with a 1/8” bit to install sheet metal screws into connector pipe. A 5/16” socket/wrench or screw driver to install pedestal trim, room air deflector, and blower assembly described below. A 1/2” socket/wrench to install flue collar. A non-combustible floor protector as specified in this manual. All chimney and chimney connector components required for your particular chimne
Resumo do conteúdo contido na página número 4
BLOWER ASSEMBLY INSTRUCTIONS THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION. Step 1. Fix the assembly to the back of the stove with the four screws provided. THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE. DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES! PEDESTAL TRIM ASSEMBLY Assemble trim pieces as shown with the screws provided in the parts bag. Washers may not be nece
Resumo do conteúdo contido na página número 5
INSTALLATION SAFETY NOTICE • I F T H I S S T O V E I S N O T P R O P E R L Y I N S T A L L E D , A H O U S E F I R E M A Y R E S U L T . T O REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. • C O N S U L T Y O U R M U N I C I P A L B U I L D I N G D E P A R T M E N T O R F I R E O F F I C I A L S A B O U T RESTRICTIONS AND IN
Resumo do conteúdo contido na página número 6
FLOOR PROTECTOR Your wood stove should be placed on a 1 inch, non-combustible surface with a k factor of 0.84. For multiple layers, add R-values of each layer to determine the overall R-value. The R value for the r e q u i r e d b o a r d i s 1 . 2 . T h e fl o o r p r o t e c t o r s h o u l d b e u n d e r t h e s t o v e , t w e n t y - s i x i n c h e s b e y o n d t h e f r o n t and six inche s beyond each side of
Resumo do conteúdo contido na página número 7
CLEARANCES TO COMBUSTIBLES It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation of the stove. Refer to the tables below : Single Wall Pipe (Double Wall Pipe) Model A B C D E F 2000 20(14) 22(20) 2 2 . 5 ( 1 6 . 5 ) 32(30) 12(11) 22(21) 2500 12 20 16 30 10.5 20 • Floor to ceiling height must be at least 7’ (84”) in all cases. • Do not place any combustible material within 4 8” of the front of the unit. • The clear
Resumo do conteúdo contido na página número 8
CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have the same diameter as the stove outlet (6”). If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draft. The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021” or 0.53 mm. It is strictly forbidden to use galvanized steel. Your smoke pipe should be assembled in
Resumo do conteúdo contido na página número 9
CHIMNEY Your wood stove may be hooked up with a 6” factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL 103 standard; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer’s specifications. If you are using a masonry chimney, it is important that it be built in compliance with the specifica - tions of the National Building Code
Resumo do conteúdo contido na página número 10
FACTORY BUILT CHIMNEY : When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney
Resumo do conteúdo contido na página número 11
MASONRY CHIMNEY : Ensure that a masonry chimney meets the minimum standards of the National Fire Protection As - sociation (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chim - ney, special methods are neede
Resumo do conteúdo contido na página número 12
Combustible Wall Chimney Connector Pass-Throughs Method A. 12” (304.8 mm) Clearance to Combustible Wall Mem- ber: Using a minimum thickness 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum wall thickness clay liner, construct a wall pass- through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its equivalent. Keep a mini - mum of 12” (304.8 mm) of brick masonry between the clay liner and wall comb
Resumo do conteúdo contido na página número 13
OUTSIDE COMBUSTION AIR Y our wood s t ov e is appr ov ed t o be ins t alled wit h an out s ide air int ak e whic h is nec es s ar y f or a m obile home. This type of installation is also required in air tight houses and houses with negative pressure problems. You can purchase this option through your heater dealer. Make sure to specify the part number mentioned in this booklet. Installation instructions are supplied with the air intake kit
Resumo do conteúdo contido na página número 14
WOODSTOVE UTILIZATION Your heating unit was designed to burn wood only; no other materials should be burned. Waste and other flammable materials should not be burned in your stove. Any type of wood may be used in your stove, but specific varieties have better energy yields than others. Please consult the following table in order to make the best possible choice. TYPE WEIGHT PER CORD EFFICIENCY SPLITS MILLIONS (LBS. CU. FT., RANKING BTU’s/CORD DRY) Hickory 63 4500 1.0 Well 31.5 White Oak
Resumo do conteúdo contido na página número 15
THE FIRST FIRES The fresh pain t on your stove needs to be cured to preserve its quality. Once the fuel charge is properly ignited, only burn small fires in your stove for the first four hours of operation. Never open the air control more than necessary to achieve a medium burn rate. Make sure that there’s enoug h air circulation while curing the stove. The odors could be smelled during the 3 or 4 first fires. Never start your sto
Resumo do conteúdo contido na página número 16
WARNINGS • N E V E R O V E R F I R E Y O U R S T O V E . I F A N Y P A R T O F T H E S T O V E S T A R T S T O G L O W R E D , OVER FIRING IS HAPPENING. READJUST THE AIR INTAKE CONTROL AT A LOWER SETTING. • THE INSTALLATION OF A LOG CRADLE or GRATES IS NOT RECOMMENDED IN YOUR WOOD STOVE. BUILD FIRE DIRECTLY ON FIREBRICK. • NEVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX. RELOADING O n c e y o u h a v e o b t a i n e d a
Resumo do conteúdo contido na página número 17
ASH DISPOSAL Ashes shoul d be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold, such as in the morning. Always dispose of ashes in a metal container with a tight fitting lid. Place this containe r on a non combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soi
Resumo do conteúdo contido na página número 18
REPAIR PARTS 1 9 2 0 17 21 18 3 7 16 1 5 11 2 3 4 5 6 7 12 10 13 8 9 29 14 27 1 2 8 30 3 1 3 6 35 34 23 32 3 3 2 2 2 6 2 4 2 5 Feed Door Assembly 7 6 5 8 1 1 0 1 1 3 4 9 2 18 Ussc
Resumo do conteúdo contido na página número 19
REPAIR PARTS Key Part No. Description Model Qty. Key Part No. Description Model Qty. 1 69515MB Feed Door Assy. 1 2000 16 22 89066 Firebrick (4.5 x 9 x 1.25) 2 25080B Feed Door Latch 1 2500 18 3 83508 5/16-18 x 3/4 Hex Head Bolt 1 23 891414 Firebrick (2-1/4 x 9) 2 4 83338 5/16-18 Lock Nut 1 24 24103 Firebrick (4-1/2 x 4-1/2) 1 5 891373 Door Hinge Pad 2 25 891530 Firebrick (4-1/2 x 7-1/2 ) 1 6 83045A Washer, 3/8” ID x 7/8” OD 2 26 40561 Ash Plug 1 7 83274 3/8-16 Lock Nut 2 2000 891777 1 2000 1 27
Resumo do conteúdo contido na página número 20
HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS COR - RECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFOR - MATION AS SHOWN IN THIS LIST: 1. THE PART NUMBER 2. THE PART DESCRIPTION 3. THE MODEL NUMBER: 2000 2500 4. THE SERI