Resumo do conteúdo contido na página número 1
MULTI FUEL PARLOR STOVE
OPERATOR’S MANUAL
Installation and Operation
MF3700, MF3800
CumberlandStoveWorks.com
CAUTION
SAVE THESE INSTRUCTIONS
• Important operating and • Read, understand and • Leave this manual with
maintenance instructions follow these instructions party responsible for use
included. for safe installation and and operation.
operation.
WARNING WARNING
Please read this entire manual before HOT! DO NOT TOUCH. SEVERE BURNS
installation and use of this pellet fuel- MAY RESU
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models TABLE OF CONTENTS WARRANTY ........................................................................................................................................................................................2 REgISTRATION, SERVICE & MAINTENANCE LOg .........................................................................................................................3 WARNINgS & CAUTIONS ................................................
Resumo do conteúdo contido na página número 4
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models WARRANTY LIMITED LIFETIME WARRANTY Ardisam, Inc., a Manufacturing Company warrants this Cumberland Stove Works Multi-Fuel Parlor Stove to be free from defects in the material or workmanship. For the lifetime of the product, Ardisam will furnish 100% parts and labor to correct any defect caused by faulty material or workmanship. For other warranty repairs, please read the three year warranty listed below. All repairs made
Resumo do conteúdo contido na página número 5
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models REGISTRATION, SERVICE AND MAINTENANCE LOG Record the model number and serial number in the space provided for easy reference. Fill out and mail the registration card located in the parts packet or register online at www.cumberlandstoveworks.com. Warranty is valid only if the completed registration is received by Ardisam, Inc. within 30 days of purchase. OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State/Province: Zip Code/Post
Resumo do conteúdo contido na página número 6
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models WARNINGS AND CAUTIONS WARNING CAUTION INDICATES A HAZARD WHICH, IF NOT AVOIDED, COULD INDICATES A HAZARD WHICH, IF NOT AVOIDED, RESULT IN DEATH OR SERIOUS INJURY AND/OR MIGHT RESULT IN MINOR OR MODERATE INJURY AND PROPERTY DAMAGE. PROPERTY DAMAGE. Read this entire manual before you install and use Proper installation of this stove is necessary for your new parlor stove. Failure to follow instructions safe and efficient operation.
Resumo do conteúdo contido na página número 7
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models CAUTION WARNING IF THE ELECTRICAL POWER FAILS ANY TIME WHEN THE Installation and repair of this parlor stove should be STOVE IS HOT, kEEP ALL STOVE DOORS CLOSED. done by a qualified service person. The appliance THE AUTOMATIC SAFETY FEATURES MUST NOT BE should be inspected before use and at least annually BYPASSED. by a qualified service person. It is imperative that WHEN RESETTING OVERTEMP NEVER USE ANY control
Resumo do conteúdo contido na página número 8
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models INTRODUCTION WARNING Congratulations on your investment in quality. Thank you NEVER BURN SEED CORN IN THE STOVE. SEED CORN for purchasing a Cumberland Stove Works Multi Fuel Par - IS TREATED WITH CHEMICAL PESTICIDES THAT ARE lor Stove from Ardisam, Inc. We have worked to ensure HARMFUL OR FATAL IF SWALLOWED, SEED CORN IS that the multi fuel burning stove meets the highest stan - DANGEROUS TO HAVE IN THE HOUSE, ESPECIALLY dards for us
Resumo do conteúdo contido na página número 9
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models PeLLetS CAUTION • A s w i t h c o r n , fi n d a c o n s i s t e n t p e l l e t s u p p l i e r . P e l l e t s w i l l vary in content and burn characteristics from supplier BURNING WOOD PELLETS ACCORDING TO RECOMMENDATIONS WILL ASSURE LONGER STOVE to supplier. A consistent supply of pellets will result in a LIFE AND LESS FREqUENT CLEANING. more consistent and efficient burn. THE USE OF GRATES OR OTHER METHODS OF
Resumo do conteúdo contido na página número 10
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models SPECIFICATIONS CAUTION Model Number MF3700, MF3800 THIS INSTALLATION MUST CONFORM WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES YOU MUST BTU/hour input (1) 45,000 max COMPLY WITH ASTM E509, (UM) 84-HUD, ULC/ORD- Heating Capacity (2) 1,200 Sq. Ft. C-48. Electrical Rating (3) 110 Volts, 15 Amp, CUMBERLAND STOVE WORkS, MANUFACTURER OF THIS APPLIANCE, RESERVES THE RIGHT TO ALTER ITS 60 Hz PRODUCTS, THEIR SPECIFICATIONS AND/OR PRICE
Resumo do conteúdo contido na página número 11
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models UNPACkING AND ASSEMBLY Unpack all hardware located in the units hopper and ash pan. The following should be included: 4 - legs (710008) w/ levelers (725010) 4 - tie-down straps (700136) 1 - firepot cleaning rod (700076) 1 - cleaning rod spring (720053) 1 - hopper lid handle (730006) 1 - power cord (720045) 1 - scraper tool (700225) 1 - door (700311) with glass (720002) and handle (700351, 700359) 1 - controller (730053) 1 - steel mou
Resumo do conteúdo contido na página número 12
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models MOUNTING THE CONTROLLER The CSW MF Series Stove has three different controller mounting options: 1. Back of the stove with controller visible.You may mount the conrollter on either side of the rear of the stove (see figure 8) so it is visible during operation. To do so use the m e t a l m o u n t i n g b r a c k e t a n d t h e ( 4 ) s e l f - t a p p i n g s c r e w s ( ( 2 ) through the plast
Resumo do conteúdo contido na página número 13
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models INSTALLATION WARNING It is recommended the stove be installed and serviced by READ THIS ENTIRE MANUAL BEFORE YOU INSTALL authorized professionals who are certified by the National AND USE THIS STOVE. FAILURE TO FOLLOW THE Fireplace Institute (NFI) as NFI Pellet Specialists. INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. Proper installation of this stove is necessary for safe and DO NOT INSTALL A FLU
Resumo do conteúdo contido na página número 14
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models CLEARANCES TO COMBUSTIBLES note: these are minimum clearances to combustible walls established by the aStm testing lab. 3” 3” 4” 3” 4” 4” 3” 6” 6” 4” Figure 14 Figure 15 STRAIGHT INSTALLATION CORNER INSTALLATION THROUGH WALL THROUGH THE WALL VENTS 3” 2” 2” 4” 3” 4” 4” 6” 4” 6” Figure 16 Figure 17 STRAIGHT INSTALLATION CORNER INSTALLATION INTERIOR VERTICAL VENTS INTERIOR VERTICAL VENTS note: when interior vertical pellet vent is used for i
Resumo do conteúdo contido na página número 15
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models VENTING WARNING Consult vent manufacturer’s specifications and DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE recommendations for all venting installations. SERVING ANOTHER APPLIANCE. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST The following installation guidelines must be followed to VENTING SYSTEM OF THIS UNIT. ensure conformity with both the safety listing of this stove and to local building codes. DO NOT CONNECT DIRECTLY TO A MASONRY
Resumo do conteúdo contido na página número 16
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models VENT TERMINATION CLEARANCES INSTALLING REMOTE THERMOSTAT The MF Parlor Stove can be run thermostatically by CLEARANCE purchasing any milivolt thermostat (sold separately). This Clearance below or beside any door or window 4 feet step is optional and not required for MF Parlor Stove to that opens. operate. Clearance above any door or window that 1 foot M o u n t t h e r m o s t a t a c c o r d i n g t o m a n u f a c t u
Resumo do conteúdo contido na página número 17
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models OUTSIDE AIR CONNECTION WARNING C o n n e c t i o n f r o m t h e i n t a k e p i p e ( 2 ” d i a m e t e r p i p e i n r e a r o f DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT s t o v e ) t o t h e o u t s i d e o f t h e h o u s e i s R E Q U I R E D f o r m o b i l e OR SYSTEM. home installation. It is recommended in tightly sealed h o m e s w i t h e x h a u s t f a n s s u c h a s
Resumo do conteúdo contido na página número 18
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models OPERATING STOVE WARNING Once the stove has been properly installed and plugged NEVER PUT STARTING PELLETS OR BURN GEL INTO into a grounded surge protector you are ready to begin THE HOPPER OF THE STOVE. THIS COULD RESULT operation. IN DEATH OR SERIOUS INJURY AND OR PROPERTY IMPORTANT: B e f o r e fi l l i n g t h e h o p p e r m a k e s u r e a l l DAMAGE. DOING SO WILL VOID ALL WARRANTIES. shipping and packaging item
Resumo do conteúdo contido na página número 19
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models lighter, close the door and press ON key. The sound D u r i n g s t a r t i n g fi r e a n d e l e c t r i c i g n i t i o n s e q u e n c e s y o u you hear after the ON key is pushed is the exhaust fan may change the level by pressing the TEMP UP or TEMP running. After the ON key is pressed the control will read DOWN buttons. as follows: D u r i n g s t a r t i n g fi r e a n d e l e c t r i c i g n
Resumo do conteúdo contido na página número 20
INSTALLATION AND OPERATION MANUAL MF3700, MF3800 Models thermoStatiC ControL oPeration WARNING The stove has been designed to be run thermostatically two different ways. There is a built-in thermostat in the NEVER SHUT DOWN YOUR STOVE BY LEAVING THE HOPPER DOOR OPEN AND UNATTENDED. THIS COULD controller, or a remote thermostat can be installed (see CREATE AN UNSAFE CONDITION IF THE DWELLING IS INSTALLING REMOTE THERMOSTAT page 14). UNDER NEGATIVE PRESSURE. LOCAL T-STAT