Resumo do conteúdo contido na página número 1
C
N
E
R
G
T
I
Decorative Gas Appliance
Model: NV360
NV580
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READTHIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: IF THE INFORMATION IN
THIS MANUAL IS NOT FOLLOWED EX-
ACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
What to do if you smell gas:
• Do not try to
Resumo do conteúdo contido na página número 2
NV360/580 Series Table of Contents Thank you and Congratulations on your purchase of a Majestic Fireplaces fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions General Information .....................................................
Resumo do conteúdo contido na página número 3
NV360/580 Series Installation & Operating Instructions This gas appliance should be installed by a qualified wood, this appliance must be installed on a metal or installer in accordance with local building codes and with wood panel extending the full width and depth of the current CSA-B149.1 Installation codes for Gas Burning appliance. Appliances and Equipment. If the unit is being installed 12. This appliance requires adequate ventilation and in a mobile home, the installation should com
Resumo do conteúdo contido na página número 4
NV360/580 Series Fireplace Dimensions Rough J Opening Depth � R � � � � Recessed C K L Nailing Flange T - Rough Opening Width � � Rough G Opening � Height F Outside Air Gas Line S Access B D C L P E M O Electrical Access N Q A G Fig. 1 Fireplace specifications and framing dimensions. 3565a Ref. NV360 NV580 NV360 Specs A 41" (1046 mm) 47" (1194 mm) 12/6/00 djt B 37 ¹⁄₂" (953 mm) 41 ¹⁄₄" (1048 mm) C 36" (914 mm) 42" (1067 mm) D 24 ¹⁄₂" (622 mm) 28 ¹⁄₂" (724 mm) E 7" (179 mm) 7" (179 mm
Resumo do conteúdo contido na página número 5
NV360/580 Series Clearance to Combustibles Appliances Top .......................................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side ......................................................... 0” (0 mm) Back ........................................................ 0” (0 mm) J Perpendicular Sidewall ........................... 0” (0 mm) I H Black Top of unit to ceiling .......................... 36” (914 mm) G Surround F
Resumo do conteúdo contido na página número 6
NV360/580 Series Framing and Finishing Air Shutter Setting Model Front Rear Check appliance to make sure it is levelled NV360RN closed closed and properly positioned. NV360RP open open NV580RN closed closed 1. Choose unit location. NV580RP open open 2. Nailing flanges are supplied with the fireplace (found on the fireplace hearth). To level the box and secure Gas Inlet & Manifold Pressures it firmly in place, remove the nailing flanges from Natural LP the hearth and install at the sides of
Resumo do conteúdo contido na página número 7
NV360/580 Series Alternate Switch Location 1/2" Gas Supply The remote switch can be installed on either side of 1/2" NPT x 3/8" Flare Shut-off Valve the access door. Mount the switch to the switch bracket 3/8" Flex Line provided. Screw the bracket on either side of the frame, (from valve) line up the screws with the prepunched holes. (Fig. 6) FP297a Fig. 4 Typical gas supply installation. The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconne
Resumo do conteúdo contido na página número 8
FRONT OF UNIT NV360/580 Series INSIDE Install the Venting System, Electrical Box Flashing and Termination NOTE: The NV360 uses a 6" B-vent system. The NV580 uses an 8" B-vent system (refer to Accessories, Page 23 for adapter). Refer venting installation instructions provided by the B-Vent manufacturer. Refer to Page 4, Figure 1 to locate chimney centerline OUTSIDE dimension from a combustible back wall. • Minimum vertical chimney height — 12 feet (3.65 m). (measured from the bottom of
Resumo do conteúdo contido na página número 9
NV360/580 Series Venting Runs Horizontal Run (in feet) 1 2 3 4 5 6 7 8 9 10 11 12 40 38 A 36 B 34 32 30 28 26 24 22 20 18 16 14 12 = Acceptable venting configuration = Unacceptable venting configuration A: Vertical installations up to 40 feet (12m) in height. Up to an 8 ft. horizontal vent run can be installed within the vent system using a maximum of two (2) 90-degree elbows or four (4) 45-degree elbows. B: Vertical installations up to 40 feet (
Resumo do conteúdo contido na página número 10
NV360/580 Series Operating Instructions Glass Information Glass Frame Only glass approved by CFM Corporation Fireplace Front should be used on this fireplace. • The use of any non-approved replacement glass will Clamps void all product warranties. Glass • Care must be taken to avoid breakage of the glass. Panel • Do not operate appliance with glass front Glass Panel removed, cracked or broken. • Replacement glass (complete with gasket) is Pull Clamp available through your Majestic Firepl
Resumo do conteúdo contido na página número 11
NV360/580 Series 1. Remove window frame assembly. (Refer to Page 10) 2. Remove logs from packaging. As with all plastics - these are not Log Top Log Top toys and should be kept away form Left Right children and infants. 3. Place rear log on rear bracket (ensure log is Log Rear seated properly, leveled and centered to the unit), so it will not move form side to side and Log is firmly positioned on the bracket. Be sure log Front is as far back as possible on bracket. Right 4. Place front
Resumo do conteúdo contido na página número 12
HI H NV360/580 Series Inspecting the Venting System Turn counterclockwise Turn clockwise This appliance venting system was designed and con- to increase to decrease structed to develop a positive flow adequate to remove flame height flame height flue gases to the outside atmosphere. HV102 Any foreign object in the venting system, except those designed specifically for the venting system, may cause Fig. 13 Flame adjustment knob for Honeywell valve. spillage of flue gases. Turn To inspect the ve
Resumo do conteúdo contido na página número 13
NV360/580 Series is not, turn the unit off and check for causes creating CAUTION: The firebox, Vent Safety Switch sensor the lack of adequate draft. and surrounding panels become very hot during normal operation. Allow time for the components to Do not operate the unit until lack of ad- cool before carrying out any service or inspection. equate draft has been determined and rectified. If the sensor is activated and shuts off the burner as- sembly, the following procedure should be followed:
Resumo do conteúdo contido na página número 14
H I P I H O WHITE L 1 5 3 4 NV360/580 Series WHITE PILOT HONEYWELL S8600 B IGNITION MODULE GND 24V MV MVPV PV SPARK 24V SENSE (BURNER) GND WHITE WHITE BLACK BLACK BLACK WHITE NOVA SIT 822 VALVE BLACK 24 VAC HOT 120 VAC RTN BLACK BLACK WHITE WHITE BLACK WHITE "ON/OFF" 120 VAC HOT 24 VAC RTN SWITCH 40VA GREEN TRANSFORMER FP670 Fig. 19 Vent Safety Switch wiring, EN/EP units. Thermopile FP670 NOVA SIT 822 VALVE WIRING DGRM. (w/ Ho
Resumo do conteúdo contido na página número 15
O 3 2 ON 1 T O NV360/580 Series Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- • If you cannot reach your gas supplier, call the ally. When lighting the pilot follow these instruc- Fire Department tions exactly. C. Use only your hand to push in or turn the gas B. BEFORE LIGH
Resumo do conteúdo contido na página número 16
NV360/580 Series Troubleshooting Honeywell VS8420 Standing Pilot Remove Glass Panel Before Servicing. ST ART CHECK • Supply line hooked up Gas Supply ON NO • Shutoff valve open YES • Lockout has engaged. Wait 60 seconds and try again. • For spark at electrode while Pilot Lights with NO depressing Piezo - 1/8" gap to Piezo Ignitor pilot hood needed. • All wiring connections • Replace Piezo ignitor YES • For air in lines • Thermopile needs a minimum 325mV. Adjust pilot flame height.
Resumo do conteúdo contido na página número 17
NV360/580 Series Troubleshooting SIT NOVA 820 MILLIVOLT VALVE NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "ON" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. POSSIBLE CAUSES SYMPTOM CORRECTIVE ACTION A. Defective or misaligned elec- 1. Spark ignitor will not light. Using a match, light pilot. If pilot lights, turn off pilot and trode at pilot. push the red button again. If pilot will not light - check gap at e
Resumo do conteúdo contido na página número 18
O O L L I I P P F F F F O O L L I I NV360/580 Series 2. Insure the rubber gasket (D) is properly positioned Fuel Conversion Instructions and install the new HI/LO pressure regulator assem- To convert the DV360/580 units for use with a different bly to the valve using the new screws (E) supplied gas follow these instructions. Before proceeding, turn with the kit. Tighten the screws securely. (Ref. torque control knob on valve to “OFF” and turn gas supply = 25 in/lb) (Fig. 23) OFF. Turn OFF an
Resumo do conteúdo contido na página número 19
NV360/580 Series 4. Remove both air shutters from burner pan by remov- Pilot ing shutter retaining screw then air shutter. (Fig. 26) Hood 5. Install air shutters supplied in kit on burner pan. Replace shutter retaining screw. For conversion to Natural Gas adjust new air shutters so slots are cov- ered. For conversion to Propane Gas, adjust new air Pilot shutters so slots are open. NOTE: NV360 air shutter Bracket has only one hole, closed. Secure shutter retaining screws. (Fig. 27) CO105a
Resumo do conteúdo contido na página número 20
NV360/580 Series Maintenance Burner and Burner Compartment It is important to keep the burner and the burner com- To obtain proper operation, it is imperative that the pilot partment clean. At least once per year the logs and lava and burner’s flame characteristics are steady, not lifting rock/ember material should be removed and the burner or floating. compartment vacuumed and wiped out. Remove and Typically, the top 3/8” or 1/2” of the thermopile should replace the logs as per the instruc