Resumo do conteúdo contido na página número 1
WOOD
Fireplace
Insert
www.regency-fi re.com
Owners & Installation Manual
MODELS: I2400M
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
918-171a FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
07/18/06
Resumo do conteúdo contido na página número 2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this Insert is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building, fi re
Resumo do conteúdo contido na página número 3
TABLE OF CONTENTS THE REGENCY I2400 WOOD INSERT SAFETY LABEL OPERATING INSTRUCTIONS Safety Label .................................................................4 Some Safety Guidelines ..............................................13 Wood Storage ..............................................................14 Ash Disposal ...............................................................14 UNIT DIMENSIONS Fan Operation ............................................................14 Creosote ...
Resumo do conteúdo contido na página número 4
SAFETY LABEL SAFETY LABEL FOR I2400M This is a copy of the label that accompanies NOTE: Regency units are constantly being your Regency Insert. We have printed a copy improved. Check the label on the unit and if of the contents here for your review. there is a difference, the label on the unit is the correct one. 4 Regency I2400M LISTED FACTORY BUILT FIREPLACE INSERT DO NOT REMOVE THIS LABEL CERTIFIED FOR USE IN CANADA AND U.S.A. CAUTION MODEL: I2400M Jan Feb Mar Apr May June
Resumo do conteúdo contido na página número 5
UNIT DIMENSIONS Regency I2400M 5
Resumo do conteúdo contido na página número 6
INSTALLATION Regency Inserts are constructed with the high- 7) Alteration of the fi replace in any manner is not CHIMNEY est quality materials and assembled under strict permitted with the following exceptions; quality control procedures that insure years of a. external trim pieces which do not affect SPECIFICATIONS trouble free and reliable performance. the operation of the fi replace may be removed providing they can be stored Before installing, check and clean your chimney It is import
Resumo do conteúdo contido na página número 7
INSTALLATION INSTALLING YOUR OPTIONAL FLUE INSERT CONNECTOR KIT Your insert is very heavy and will require two The Straight Flue Adaptor (Part #846-504) or three people to move it into position. The shown here, may be used to produce a secure insert can be made a little lighter by removing connection between your fl ue connector and the the cast iron door by opening it and lifting it insert collar. Detailed installation instructions are off its hinges. Be sure to protect your hearth in
Resumo do conteúdo contido na página número 8
INSTALLATION MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below. Adjacent Mantle** Top Side Minimum Minimum Minimum Unit Side Wall (to Top) Facing Facing Hearth Hearth Hearth Side (to Side) (to Top) (to Side) Extension* Thickness* Extension A B C D E F G Medium Flush Insert (I2400) 11"/280mm 20"/508mm 12"/305mm 8"/200mm 18"/455mm 0.5"/13mm 8"/200mm Sid
Resumo do conteúdo contido na página número 9
INSTALLATION FLUE CONNECTOR STEP-BY-STEP BRACKET INSTALLATION INTO A FACTORY BUILT Package contains: 3 brackets and 6 screws. FIREPLACE These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the 1) When installed in a factory built fi replace, a connection. The brackets are screwed into the full stainless steel rigid or fl exible fl ue liner top of the Insert in the pre-punched holes and is mandatory, for both safety and perform- then screwed into the fl ue
Resumo do conteúdo contido na página número 10
INSTALLATION STEP-BY-STEP INSTALLATION OF THE FACEPLATE AND TRIM Note: It may be easier to install the insula- Prior to sliding your insert into its fi nal position tion, faceplate top and faceplate trim and attaching the connector or liner pipe, the faceplate side panel plates must be installed with the unit pulled slightly away from the fi replace face. If this is done, be as follows: very careful not to disturb the con- nector when shifting the unit to its fi nal position. 1) Slide the sp
Resumo do conteúdo contido na página número 11
White Low (Red) High (Black) INSTALLATION STEP-BY-STEP INSTALLATION OF THE FAN/BLOWER Your fan should only be installed once the unit is 3) Slide the supports into the clips. The tension Do not turn fan ON until your insert has in place in order to prevent any damage to the holding the clips in place may be adjusted by reached operating temperature or at least fan. To attach, follow the instructions provided increasing or decreasing the offset spacing 30 minutes after starting fi re. with the f
Resumo do conteúdo contido na página número 12
INSTALLATION ensure the tube will not move when the unit FLOOR PROTECTION DRAFT CONTROL is burning. Though there are four air tubes in the medium units. Please check to ensure that your fl oor protection Before establishing your fi rst fi re, it is important and hearth will meet the standards for clearance that your fully understand the operation of you 2) Slide the left baffl e over the air tubes from to combustibles. Your hearth extension must be draft control. The draft rod is on the left
Resumo do conteúdo contido na página número 13
OPERATING INSTRUCTIONS 13) Do not store any fuel closer than 2 feet from FIRST FIRE SOME SAFETY your unit. GUIDELINES When your installation is completed and in- 14) Do not burn salt drift wood as it will corrode spected, you are ready for your fi rst fi re. your unit and void the warranty. 1) Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or 1) Open draft control fully. 15) Do not operate the unit if the glass is broken similar liquids to start or ‘freshen
Resumo do conteúdo contido na página número 14
OPERATING INSTRUCTIONS 9) During the fi rst few hours it may be more ASH DISPOSAL CREOSOTE diffi cult to start the fi re. As you dry out your fi re brick and your masonry fl ue (if During constant use, ashes should be removed When wood is burned slowly, it produces tar and applicable), your draft will increase. every few days. Please take care to prevent the other organic vapors, which form creosote when build-up of ash around the start-up air housing combined with moisture. The creosote vapors
Resumo do conteúdo contido na página número 15
MAINTENANCE MAINTENANCE OF GLASS CLEANING GOLD-PLATED DOORS Only clean your glass window when it is cool. Your local retailer can supply you with special The gold electroplated fi nish on the doors glass cleaner if plain water and a soft cloth does requires little maintenance, and need only be not remove all deposits. cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty. GLASS REPLACEMENT Your Regency Insert is sup
Resumo do conteúdo contido na página número 16
PARTS LIST MAIN ASSEMBLY & OPTIONS - I2400M Part # Description Part # Description Part # Description 1) 846-910 Door Assy - Large Gold 42) 163-932 Convection Grill - Gold (Opt) 142-917 Fan Assembly (no glass) 24) 910-157/P Fan Motor 120 Volts 163-930 Convection Grill - Blk (Opt) 846-916 Door Assy - Large Blk 25) 910-678 Power Cord 120 Volts 43) * Hex Nut 10-24 Zinc Coated (no glass) 44) * Washer #10 Flat 27) 910-142 Fan Thermodisc 2) 846-3
Resumo do conteúdo contido na página número 17
PARTS LIST FACEPLATES - I2400M Part # Description 140-911 Faceplate & Trim Set - Regular 285) 143-161 Trim Right Regular 286) 143-158 Trim Top Regular 287) 143-160 Trim Left Regular 288) * Faceplate Side Regular 289) * Faceplate Top Regular 140-913 Faceplate & Trim Set - Oversize 295) 143-164 Trim Right Oversize 296) 143-162 Trim Top Oversize 297) 143-163 Trim Left Oversize 298) * Faceplate Side Oversize 299) * Faceplate Top Oversize *Not available as a replacement part.
Resumo do conteúdo contido na página número 18
PARTS LIST BRICK PANELS - I2400M Part # Description 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 75) 802-122 Brick Partial: 1-1/4 x 4-1/2" x 2" 76) 802-152 Brick Partial: 1-1/4" x 2" x 9" 18 Regency I2400M
Resumo do conteúdo contido na página número 19
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable. The Warranty: Lifetime Covered under the agreement are the following components: Firebox, ceramic baffl e, vermiculite baffl e, con
Resumo do conteúdo contido na página número 20
Regency fi replace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assur- ance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products Interna- tional Ltd. is pleased to extend this Limited Lifetime Warranty to the origi- nal purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fi re.com Installer: Please complete the following informati