Resumo do conteúdo contido na página número 1
I1200S
Wood Insert
www.regency-fi re.com
Owners & Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
918-665a FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
07/12/07
Resumo do conteúdo contido na página número 2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this Insert is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building or fi
Resumo do conteúdo contido na página número 3
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Safety Label ..................................................................4 First Fire ......................................................................16 Fan Operation .............................................................17 Ash Disposal ...............................................................17 UNIT DIMENSIONS Some Safety Guidelines ..............................................17 With Standard Flue Adaptor .........
Resumo do conteúdo contido na página número 4
326 SAFETY LABEL This is a copy of the label that accompanies each I1200S Wood Insert. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. 4 I1200 Regency Wood Insert DO NOT REMOVE THIS LABEL LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U.S.A. MODEL: I1200S 326 CAUTION TESTED TO: ULC S628-M93 / UL 1482-199
Resumo do conteúdo contido na página número 5
UNIT DIMENSIONS WITH STANDARD FLUE ADAPTOR 6" (152mm) Diameter STANDARD FLUE ADAPTOR (171-932) I1200 Regency Wood Insert 5
Resumo do conteúdo contido na página número 6
UNIT DIMENSIONS WITH OFFSET FLUE ADAPTOR 6" (152mm) Diameter OFFSET FLUE ADAPTOR (171-936) 6 I1200 Regency Wood Insert
Resumo do conteúdo contido na página número 7
INSTALLATION Regency Inserts are constructed with the high- 6) Alteration of the fi replace in any manner is not CHIMNEY est quality materials and assembled under strict permitted with the following exceptions; quality control procedures that ensure years of SPECIFICATIONS trouble free and reliable performance. a. external trim pieces which do not affect the operation of the fi replace may be Before installing, check and clean your chimney It is important that you read this manual thor- r
Resumo do conteúdo contido na página número 8
INSTALLATION MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below. Adjacent Mantle** Top Side Minimum Minimum Minimum Unit Side Wall (to Top) Facing Facing Hearth Hearth Hearth Side (to Side) (to Top) (to Side) Extension* Thickness* Extension A B C D E F G I1200S 15" (381mm) 20" (508mm) 14" (356mm) 7.375"(187mm) 16" (406mm) 1.5" (38mm) 8" (203mm) Side an
Resumo do conteúdo contido na página número 9
INSTALLATION 3) Install the unit by fi rst setting the rear of 7) Ensure that the unit is still level. INSTALLING the unit into the fi replace. See diagram YOUR INSERT 3. Ensure that the unit is centered in the 8) To complete the installation and to ensure a existing fi replace and lined up with the fl ue secure fi t and connection of the fl ue adaptor adaptor. to the insert, it is essential that the two bolts, SAFETY NOTE: The insert is very heavy and fl at washers and lock washers (supplied
Resumo do conteúdo contido na página número 10
INSTALLATION 4) If the fl oor of your fi replace is below the INSTALLATION INTO A In Canada this fi replace insert must be level of the fi replace opening, adjust the installed with a continuous chimney liner insert's levelling bolts to accommodate the MASONRY FIREPLACE of 6" diameter extending from the fi re- difference. When additional shimming is place insert to the top of the chimney. The required, use non-combustible masonry or When referencing installation or connec- chimney liner must
Resumo do conteúdo contido na página número 11
INSTALLATION FACEPLATE, TRIM & OPTIONAL BOTTOM FACEPLATE & FAN SUPPORT INSTALLATION Regular/Oversize Faceplate Installation: Optional Regular/Oversize Bottom Faceplate Installation: 1) Thread the black 1/4" x 3/4" long hex bolts into the faceplate mount- ing bracket as shown in Diagram 1, leaving them approximately 1/4" 4) Position the assembled faceplate side and top to the insert. Ensure out. to align the draft rod into the opening of the faceplate as well as the side faceplate slots wit
Resumo do conteúdo contido na página número 12
INSTALLATION 12) Mount the completed faceplate / trim assembly to the insert. Ensure Regular/Oversize Faceplate Trim Installation: to align the side faceplate slots with the hex bolts in the mounting (Black Trim included with Regular/Oversize Faceplate brackets and tighten to secure in place. or Optional Brass Trim) 8) Measure the total height of the faceplate assembly and cut both the Fan Installation: left and right side trim accordingly using a metal cutting blade. 13) Install the fan asse
Resumo do conteúdo contido na página número 13
INSTALLATION 15) Cut the bottom edge of the fan support (using a metal cutting blade) 18) Secure the fan support to the fan assembly using 4 self tapping to the length measured in step 14. screws. See Diagram 9. 16) Remove the fan assembly from the ash lip of the insert and position 19) Re-attach the fan/fan support assembly to the ash lip of the insert. the fan support to the bottom of the fan assembly. 17) Drill 4 x 5/32" holes to the underside of the fan assembly using the holes in the fan
Resumo do conteúdo contido na página número 14
White Low (Red) High (Black) INSTALLATION FAN / BLOWER Do not turn fan ON until your insert has Your fan should only be installed once the unit WARNING: reached operating temperature or at least is in place in order to prevent any damage to Electrical Grounding Instructions the fan. 30 minutes after starting fi re. This appliance is equipped with a three pronged (grounding) plug for 1) Align the fan support with the offset clip on the bottom of the ashlip. CAUTION: Label all wires prior
Resumo do conteúdo contido na página número 15
INSTALLATION 4) Important: push both baffl e bricks so FIREBRICK ASSEMBLY BRICK FLUE BAFFLE & they are tight against the side walls and SECONDARY AIR TUBE to the back. Firebrick is included to extend the life of your insert and radiate heat more evenly. Check to INSTALLATION see that all fi rebricks are in their correct posi- tions and have not become misaligned during The fl ue baffl e system located in the upper area shipping. of the fi rebox is removable to make cleaning your chimney sys
Resumo do conteúdo contido na página número 16
INSTALLATION 9) During the fi rst few hours it may be more SCREEN DOOR FIRST FIRE diffi cult to start the fi re. As you dry out your fi re brick and your masonry fl ue (if Hook screen to the inside on the right side When your installation is completed and in- applicable), your draft will increase. of the fi rebox door opening. Lock in place by spected, you are ready for your fi rst fi re. turning handle. 10) For those units installed at higher elevations 1) Open draft control fully. or into sub-s
Resumo do conteúdo contido na página número 17
OPERATING INSTRUCTIONS 15) Do not store any fuel closer than 2 feet from FAN OPERATION SOME SAFETY your unit. GUIDELINES The fan is to be operated only with the draft 16) Do not burn salt drift wood as it will corrode control rod pulled out at least 1/2" from the your unit and void the warranty. 1) Never use gasoline, gasoline type lantern fu- fully closed position. The fan is not to be els, kerosene, charcoal lighter fuel, or similar operated when the draft control rod is in the 17) Do
Resumo do conteúdo contido na página número 18
MAINTENANCE 3) Only burn seasoned wood! Avoid burning DOOR LATCH GLASS REMOVAL wet or green wood. Seasoned wood has been dried at least one year. ADJUSTMENT Allow the stove to cool before removing or replac- ing glass. Remove the door from the insert and 4) A small hot fi re is preferable to a large The door latch may require adjustment as the remove the glass retainer. Use caution when smouldering one that can deposit creosote door gasket material compresses over time. removing broken
Resumo do conteúdo contido na página número 19
PARTS LIST MAIN ASSEMBLY Part # Description 850-141 Black Door - Complete 850-142 Gold Door - Complete 850-143 Nickel Accent Door - Complete 850-144 Gold Accent Door - Complete 2) 846-302 Glass - Replacement 4) 936-243 7/8" Adhesive Tape Gasket 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screws - 1/4-20 x 3/8" 8) 948-170/P Glass Retainer 9) 846-973 Door Handle Assembly 16) 846-570 Med. Density Door Gasket Kit 17) 846-918 Hinge Caps (2/set) - Gold 19) 948-101 Spring Ha
Resumo do conteúdo contido na página número 20
PARTS LIST FACEPLATES Part # Description 171-920 Faceplate & Trim Set - Regular - Black 60) * Faceplate Right Side Regular / Oversize 171-924 Trim Set - Regular Brass 61) * Faceplate Left Side Regular / Oversize 62) * Faceplate Top Regular / Oversize 171-922 Faceplate & Trim Set - Oversize - Black 171-926 Trim Set - Oversize Brass 64) * Bottom 1 Piece Faceplate 65) * Fan Support 171-928 Bottom Piece and Fan Support - Regular 171-930 Bottom Piece and Fan Support - Oversize