Resumo do conteúdo contido na página número 1
™
Owners &
E33 Sunrise Gas Insert
Installation Manual
MODELS: E33S-NG1 Natural Gas E33S-LP1 Propane
www.regency-fi re.com
WARNING: FOR YOUR SAFETY
If the information in these instructions are not followed exactly, What to do if you smell gas:
a fi re or explosion may result causing property damage, Do not try to light any appliance
personal injury or loss of life. Do not touch any electrical switch:
do not use any phone in your
FOR YOUR SAFETY
building.
Do not store or use gasoline
Resumo do conteúdo contido na página número 2
FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Insert by FPI. TM The E33 Sunrise Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The E33S-NG1 and E33S-LP1 have been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please tak
Resumo do conteúdo contido na página número 3
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Final Check..................................................................21 Copy of the Safety Label ...............................................4 First Fire ......................................................................21 Operating Instructions .................................................21 REQUIREMENTS Lighting Procedure ......................................................21 Shutdown Procedure .........................
Resumo do conteúdo contido na página número 4
SAFETY LABEL This is a copy of the safety label that TM accompanies the E33 Sunrise Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened. NOTE: FPI units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. For the State of Massachusetts, installation and repair must be done by a pl
Resumo do conteúdo contido na página número 5
INSTALLATION REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above
Resumo do conteúdo contido na página número 6
UNIT DIMENSIONS ® 6 Regency E33S-1 Sunrise Gas Insert INSTALLATION
Resumo do conteúdo contido na página número 7
INSTALLATION INSTALLATION INSTALLATION INTO A BEFORE YOU START IMPORTANT MESSAGE SOLID FUEL BURNING SAVE THESE Safe installation and operation of this appliance FIREPLACE OR requires common sense, however, we are INSTRUCTIONS required by the Canadian Safety Standards FACTORY BUILT The FPI Gas Insert must be installed in accord- and ANSI Standards to make you aware of ance with these instructions. Carefully read all the following: FIREPLACE the instructions in this manual fi rst. Consult
Resumo do conteúdo contido na página número 8
INSTALLATION 11) Due to high temperatures, the appliance a. Glass Crystals MINIMUM FIREPLACE should be located out of high traffi c areas b. Contemporary Faceplate and away from furniture and draperies. c. Remote Control OPENING Children and adults should be alerted to d. Wall Thermostat the hazards of high surface temperatures, The minimum fi replace opening is shown in the especially the fi replace glass, and should 9) Final check. Refer to the "Final Check" following diagrams: stay away
Resumo do conteúdo contido na página número 9
INSTALLATION INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLES From Unit Side Walls A* 8" (203 mm) Ceiling B 47" (1194 mm) Min. Mantel Height C 15" (381 mm) Max. Mantel Depth D 3-1/2" (89 mm) Alcove Width E 76" (1930 mm) Alcove Depth F 36" (914 mm) * Alcove side wall must have a min. of 8" clearance on one side. COMBUSTIBLE MANTEL CLEARANCES Due to the extreme heat this fi replace emits, the mantel clearances are critical. Note: A non-combustibl
Resumo do conteúdo contido na página número 10
INSTALLATION FLUE LINER Part # Description GAS CONNECTION 948-305 3" Flex - 35 ft. INSTALLATION 946-529 FPI Co-linear DV Vertical GAS CONNECTION WARNING: Termination Cap 1) Cut the fl ex liner as required. Only persons licensed to work with gas piping may make the 2) Mark the end of one liner with an "E" to Alternate Approved Caps necessary gas connections to indicate Exhaust. 46DVA-VC Vertical Termination Cap this appliance. 46DVA-VCH High Wind Cap 3) Connect the other end of
Resumo do conteúdo contido na página número 11
INSTALLATION INSTALLATION GAS INSERT GAS PIPE SIT VALVE DESCRIPTION AERATION SYSTEM PRESSURE TESTING 1) Gas on/off knob The appliance must be isolated from the gas 2) Manual high/low adjustment The burner aeration is factory set but may need supply piping system by closing its individual 3) Pilot Adjustment adjusting due to either the local gas supply or manual shut-off valve during any pressure 4) Thermocouple Connection - option altitude. Open the air shutter for a blue fl ame testing of
Resumo do conteúdo contido na página número 12
INSTALLATION CONVERSION KIT #434-969FROM NG TO LP ® 12 Regency E33S-1 Sunrise Gas Insert INSTALLATION
Resumo do conteúdo contido na página número 13
INSTALLATION INSTALLATION ® Regency E33S-1 Sunrise Gas Insert 13
Resumo do conteúdo contido na página número 14
INSTALLATION ® 14 Regency E33S-1 Sunrise Gas Insert INSTALLATION
Resumo do conteúdo contido na página número 15
INSTALLATION INSTALLATION WIRING DIAGRAMS This heater does not require a 120V A.C. supply Caution: Ensure that WARNING: Electrical Grounding Instructions for operation. However, a 120V A.C. power This appliance is equipped with a three pronged the wires do not touch supply is needed for the fan/blower operation. (grounding) plug for your protection against shock any hot surfaces and hazard and should be plugged directly into a properly are away from sharp grounded three-prong receptacle
Resumo do conteúdo contido na página número 16
O L N O To thermopile INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. 3) Install 3 AAA alkaline batteries in transmitter It is recommended that the thermostat be OPTIONAL REMOTE and 4 AA alkaline batteries in the receiver. installed on an interior wall. Install the receiver and its cover in the wall. CONTROL Switch the remote receiver to "remote" CAUTION mode. The remote c
Resumo do conteúdo contido na página número 17
INSTALLATION INSTALLATION GLASS CRYSTAL OR OPTIONAL CERAMIC STONES INSTALLATION Spread the supplied Glass Crystals (or optional Ceramic Spa Stones) evenly over the burner. Ensure the crystals (stones) do not overlap too much as this will effect the fl ame pattern. NOTE: When installing, use either the supplied Glass Crystals or optional Ceramic Spa Stones - DO NOT combine the two when installing on Models P33S/ E33S/ L676S. Only the supplied approved Cobalt Blue Glass or optional Ceramic Sp
Resumo do conteúdo contido na página número 18
INSTALLATION CONTEMPORARY FACEPLATE & DOOR FRAME INSTALLATION 3) Secure loose wires using wire clips along the back of the left side Kit# 341-914 Contents List: of the faceplate. Ensure to run the wires away from the fi rebox as much as possible. 1 Complete Faceplate with Switches 1 Door Frame 4) Align the faceplate tabs with the tab brackets on the inside top of the 1 Bottom Louver fi rebox and slide in place. 2 Hinges 4 Hinge Screws NOTE: For easy installation do not force both tabs in at th
Resumo do conteúdo contido na página número 19
INSTALLATION INSTALLATION 5) Secure the bottom of the faceplate to the fi rebox fl ange using one 8) Align the left and right side hinge with the screw holes in the bottom screw on each side. louver and secure in place using 3 screws per side. NOTE: Ensure that the bottom of the faceplate leg is aligned with the screw hole on the inner side of the fi rebox fl ange. 9) Install the door frame by hooking the top fl ange over top of the glass door, push in the bottom of the door frame to secure in pl
Resumo do conteúdo contido na página número 20
INSTALLATION OPTIONAL HEARTH TRIM INSTALLATION The Hearth Trim is an option that can be used to fi nish off the installation when the bottom of the fi replace is higher than the hearth or to raise the fi replace. The faceplate is assembled fi rst and then the hearth trim is attached to the faceplate. There are 2 Hearth Trim options; a 2" and a 4". 4" Hearth Trim (341-944) Installation: 2" Hearth Trim (341-942) Installation: 1) Secure the two 2" hearth trim pieces together as shown in 1) Attach th