Gas Fireplaces
P33 Gas Fireplace
P33 Zero Clearance Direct Vent Gas Fireplace
P33 WITH THE FLUSH OR BAY FRONT
Model P33-NG4 P33-LP4
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 3.3” W.C. (0.82 kPa)
#44 DMS - 0-2000ft
Orifi ce Size #54 DMS
#45 DMS - 2000-4500ft
Minimum Input 12,500 BTU/h
Altitude 0-2000 ft. (0-610m) (3.66 kW)
10,500 BTU/h
Resumo do conteúdo contido na página número 2
Gas Fireplaces Gas Fireplaces P33 Gas Fireplace P33-NG4 w/ P33-LP4 w/ Model Contemporary Contemporary Faceplate Faceplate Fuel Type Natural Gas Propane Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa) Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa) Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 3.3” W.C. (0.82 kPa) Orifi ce Size #47 DMS #56 DMS Minimum Input 9,800 BTU/h 9,000 BTU/h Altitude 0-4500 ft. (0-1372m) (2.87 kW) (2.64 kW) Maximum Input 17,500 BTU/h 15,500
Resumo do conteúdo contido na página número 3
Gas Fireplaces P33 Gas Fireplace Framing and Finishing Vent Clearances Clearance Dimension Horizontal - Top 2-1/2” (64mm) 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front Horizontal - Side 1-1/2” (38mm) of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼” Horizontal - Bottom 1-1/2” (38mm) (32mm) thick. Vertical - Flex 1-1/2” (38mm) 2) Frame in the enclosure for the unit with framing
Resumo do conteúdo contido na página número 4
Gas Fireplaces Gas Fireplaces P33 Gas Fireplace Clearance Requirements with Combustible Mantels with Contemporary Faceplate Contemporary Faceplate Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher. C C B Close to Ceiling *Note: All measurements are from the top/side of the unit, not optional front. Clearance:
Resumo do conteúdo contido na página número 5
Gas Fireplaces P33 Gas Fireplace FPI Direct Vent System (Flex) Horizontal Terminations Only Important When installing Cabinet Mantels: the wall thimble must be secured This venting system, in combination with the P33 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by fi rst and venting must be attached to unit before sliding into fi nal position. Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Loca
Resumo do conteúdo contido na página número 6
Gas Fireplaces Gas Fireplaces P33 Gas Fireplace Rigid Pipe Venting Horizontal or Vertical Terminations 2 4 6 8 10 12 12 14 16 18 20 22 24 26 28 30 40 38 36 34 2 4 8 6 10 12 32 40 30 38 28 2 4 6 8 10 12 Alternate Horizontal 36 Termination Caps 26 34 40 24 32 38 22 30 36 28 20 34 If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11) 26 18 32 Venting Arrangements - Vertical 24 16 30 Terminations Rigid Pipe System 22 14 28 (Propan
Resumo do conteúdo contido na página número 7
Gas Fireplaces P33 Gas Fireplace Vertical Venting with Two (2) 90° Elbows Vertical Venting with Three (3) 90° - Initial vertical section. Elbows - Initial vertical section. Two 45° elbows = One 90° elbow Two 45° elbows = One 90° elbow Option V H V+ V1 Maximum total pipe: length, of Option V H + H1 V+ V1 Maximum total pipe: length, of all sections, must not exceed all sections, must not exceed A) 1’ Min. 4’ Max. 2’ Min. A) 2’ Min. 3’ Max. 4’ Min. 30 feet. 30 feet. Total horizontal sections
Resumo do conteúdo contido na página número 8
Gas Fireplaces Gas Fireplaces P33 Gas Fireplace • Maintain clearances to combustibles. Venting Arrangements - Horizontal • Horizontal vent must be supported every 3 feet. Terminations • Firestops are required at each fl oor level and whenever passing through a wall. This lightly shaded area of the diagram shows allowable combinations of vertical runs with horizontal terminations, using one 45° and one A vent guard may be required as per local codes, refer to Exterior 90° elbow (two 45º
Resumo do conteúdo contido na página número 9
Gas Fireplaces P33 Gas Fireplace Horizontal Venting with Two (2) 90° Horizontal Venting with Three (3) 90° Elbows - Initial vertical section. Elbows - Initial vertical section. Two 45° elbows = One 90° elbow Two 45° elbows = One 90° elbow Option V H+ H1 Maximum total pipe: length, of Option V H V+ V1 H + H1 Maximum total all sections, must not exceed pipe: length, of A) 1’ Min. 3’ Max. A) 2’ Min. 1’ Max. 3’ Min. 4’ Max. 30 feet. all sections, must Total horizontal sections must not exceed 3
Resumo do conteúdo contido na página número 10
Gas Fireplaces Gas Fireplaces P33 Gas Fireplace Vertical termination with co-linear Required Parts: fl ex system Part # Description 946-529 Co-linear DV Vertical Termination Cap The appliance must not be connected to a chimney fl ue 948-305 3” Flex - 35 ft. serving a separate solid fuel burning appliance. 946-563 Coaxial to Co-linear Adapter Kit 510-994 Rigid Pipe Adapter Masonry chimneys may take various contours which the fl exible liner 58dva-E45 45º Elbow will accommodate. However, keep th