Resumo do conteúdo contido na página número 1
1
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z21.11.2, VOLUME II FOR UNVENTED ROOM HEATERS.
UNVENTED MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
UNVENTED GAS FIREPLACE
NATURAL GAS MODEL GVF36N
PROPANE GAS MODEL GVF36P
CERTIFIED FOR UNITED STATES USING ANSI METHODS
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property dama
Resumo do conteúdo contido na página número 2
2 TABLE of CONTENTS PG 3-4 INTRODUCTION 11-13 OPTIONS Warranty Patented Catalytic Glass Door General Instructions Blower Installation General Information Fan & Thermostatic Sensor Installation Care of Glass Door, Catalytic Tiles & 14-15 OPERATION / MAINTENANCE Plated Parts Operating Instructions 5-7 INSTALLATION Maintenance Combustion and Ventilation Air Provisions Catalytic Tile Maintenance Determining Confined or Unconfined Space Oxygen Depletion Sensor Pilot Cleaning Gas Installation Pilot Fl
Resumo do conteúdo contido na página número 3
3 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is test-fired and thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, re
Resumo do conteúdo contido na página número 4
4 This fireplace is only for use with the type of gas indi- GENERAL INSTRUCTIONS cated on the rating plate. This fireplace is not convert- THIS GAS FIREPLACE SHOULD BE INSTALLED AND ible for use with other gases, unless a certified kit is SERVICED BY A QUALIFIED INSTALLER to conform with used. local codes. Installation practices vary from region to re- Minimum inlet gas supply pressure is 4.5 inches water gion and it is important to know the specifics that apply to column for natural gas and 1
Resumo do conteúdo contido na página número 5
5 INSTALLATION COMBUSTION & VENTILATION DETERMINING CONFINED OR AIR PROVISIONS UNCONFINED SPACE To determine the volume of the room where the heater is This heater shall not be installed in a confined space or to be installed, multiply the width x the length x the ceiling unusually tight construction unless provisions are pro- vided for adequate combustion and ventilation air. height of that room measured in feet. If any adjoining rooms are connected by grills or openings such as kitchen pass-
Resumo do conteúdo contido na página número 6
O H L I L I O L P P F F O 6 Unusually tight construction is defined as con- GAS INSTALLATION struction where: 1. Move the fireplace into position and secure using the a) Walls and ceilings exposed to the outside atmos- nailing tabs and/or secure to the floor through the ¼"ø phere have a continuous water vapour retarder with a -11 2 holes located at either end of the base. rating of 1 perm (6 x 10 kg per pa-sec-m ) or less with openings gasketed or sealed, and 2. Install rigid black pipe, 1/2" ty
Resumo do conteúdo contido na página número 7
7 Combustible materials may be installed flush with the front FRAMING of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, It is best to frame your fireplace after it is positioned. Use 2x4's and frame to local building codes. FIGURE 5-7. stone or ceramic tile) may protrude in these areas. It is not necessary to install a hearth extension with this fireplace system. FIGURE 5 When roughing in the fireplace, raise the fireplace to ac-
Resumo do conteúdo contido na página número 8
8 FINISHING HOOD LOGO PLACEMENT Remove the FIGURE 11 backing of the logo supplied and place on the HOOD screen cover, as indicated. CURTAIN MESH FIGURE 13 CATALYTIC DOOR OPENING & CLOSING CATALYTIC DOOR OPEN- FLANGE The curtain mesh must be kept fully closed during opera- ING AND CLOSING (IF AP- HOOD CLIP tion to help prevent accidental burns from occurring. PLICABLE): The upper lou- vres must be removed to FIGURE 12 allow the catalytic door to be opened or closed. To UPPER LOUVRE access the
Resumo do conteúdo contido na página número 9
9 LOG PLACEMENT TM PHAZER logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to care- fully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the fire- place, the colours will become more uniform as colour pigments burn in during the heat activated curing process. #5 FIGURE 15a-f 4. Position the notch located on the end of the center
Resumo do conteúdo contido na página número 10
10 GVFL LOUVRE INSTALLATION L36 LOUVRE INSTALLATION UPPER LOUVRES: In- FIGURE17 FIGURE 16a-c sert the upper louvres HOOD into the slots on both A BRACKET brackets. Press the top SLOT flange of the hood into the four clips located along the top of the unit LOUVRE A as shown. LOWER LOUVRES: At- tach each hinge to the fire- box with 2 screws. B LOWER LOUVRES B (VALVE CONTROL DOOR) HINGE SCREEN C C HINGE SCREEN: Position the hinge screen into place and with the control door open, secure to the fir
Resumo do conteúdo contido na página número 11
11 OPTIONS GVF103-KT - PATENTED CATALYTIC DOOR HINGE DOOR INSTALLATION NOTE: ORNAMENTAL INSETS CAN NOT BE USED IN CONJUNCTION WITH THE CATALYTIC DOOR This unique patented catalytic system was designed to provide unparalleled safety and peace of mind. The top of the door contains four catalytic tiles which are designed to filter out combustion gases and limit the carbon monox- 3 ide output. It is likely that with the fireplace in operation, the catalytic tiles will actually scrub the carbon monox
Resumo do conteúdo contido na página número 12
black white 12 OPTIONAL BLOWER INSTALLATION FIGURE 22 INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accord- ance with local codes. In the absence of local codes, use the current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE. FIGURE 19 If the fireplace was not previously equipped with a blower: route a Attach the connectors from the grounded 2-wire, 60hz black and red wires to the power cable to the blower. junction box. At this Attach and secure the
Resumo do conteúdo contido na página número 13
13 GD65 FAN INSTALLATION THERMOSTATIC SENSOR CONTROL ELECTRICAL INSTALLA- This optional kit is meant to be used only in conjunction TION TO BE DONE BY A with the GD65 Fan Kit, which may be ordered from your QUALIFIED INSTALLER and Wolf Steel /Napoleon dealer. must be connected and With the thermostatic sensor option, the fan, when turned grounded in accordance with on, becomes thermally activated, and will automatically local codes. In the absence run approximately 10 minutes after the fireplac
Resumo do conteúdo contido na página número 14
O H L I L I I O L P P F F O N O T O 14 OPERATION / MAINTENANCE After extended periods of non-operation such as fol- After extended periods of non-operation such as fol- After extended periods of non-operation such as fol- After extended periods of non-operation such as fol- After extended periods of non-operation such as fol- If heater shuts off, do not relight until you provide fresh If heater shuts off, do not relight until you provide fresh If heater shuts off, do not relight until you provid
Resumo do conteúdo contido na página número 15
15 OXYGEN DEPLETION SENSOR PILOT MAINTENANCE CLEANING TURN OFF THE GAS AND ELECTRICAL POWER This procedure must be performed by a qualified BEFORE SERVICING THE FIREPLACE. service person! CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and Inspect the pilot for any visible contamination or debris (usually lint, pet hair, spider webs, carpet fibre, etc.) and dangerous operation. Verify proper operation after servic- remove. ing. This heate
Resumo do conteúdo contido na página número 16
16 REPLACEMENTS Contact your dealer or the factory for questions concerning When ordering replacement parts always give the follow- prices and policies on replacement parts. Normally all parts ing information: can be ordered through your Napoleon dealer or distribu- 1. MODEL & SERIAL NUMBER OF FIREPLACE tor. 2. INSTALLATION DATE OF FIREPLACE 3. PART NUMBER FOR FOR WARRANTY WARRANTY REPL REPLA ACEMENT CEMENT PPAR ARTS TS, , A A PHO PHOTTOCOPY OCOPY OF OF THE THE FOR FOR FOR WARRANTY WA
Resumo do conteúdo contido na página número 17
17 W415-0297 / D / 04.03.03
Resumo do conteúdo contido na página número 18
18 TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED. SYMPTOM PROBLEM TEST SOLUTION Main burner goes Pilot flame is not large - service or replace Oxygen Depletion Sensor System out; pilot stays on. enough or not engulfing the - correct piping and/or regulator to provide correct pressure thermopile Thermopile shorting - clean thermopile connection to the valve. Reconnect. - replace Oxygen Deple
Resumo do conteúdo contido na página número 19
O H L I L I O L P P F F O 19 SYMPTOM PROBLEM TEST SOLUTION Pilot goes out Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- while standing; ishes or extinguishes, especially when main burner ignites. Monitor Main burner is in appliance supply working pressure. 'OFF' position. - check if supply piping size is to code. Correct all undersized piping. Main burner will not Inlet pressure too high. Adjust inlet pressure to ensure maximum 7.0” W.C. at gas
Resumo do conteúdo contido na página número 20
20 W415-0297 / D / 04.03.03 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Service Technician Date Dealer Name Service Performed Special Concerns Name