Resumo do conteúdo contido na página número 1
Owner’s Manual
Installation and Operation
Models:
6000TR-OAK
6000TR-OAK-IPI
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IMPROPER INSTALLA-
GUIDE MUST BE LEFT WITH APPLIANCE FOR
TION, ADJUSTMENT, ALTERATION,
FUTURE REFERENCE.
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
WARNING: IF THE INFORMATION
ASSISTANCE OR ADDITIONAL INFOR-
IN THESE INSTRUCTIONS IS NOT
MATION CONSULT A QUA
Resumo do conteúdo contido na página número 2
SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully ! ! described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !
Resumo do conteúdo contido na página número 3
TABLE OF CONTENTS Safety and Warning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes ............................................... 8 Appliance Certification................................................................... 8 Installation Codes.......................................................................... 8 High Altitude Installations ...........
Resumo do conteúdo contido na página número 4
6000TR-OAK 6000TR-OAK-IPI Service Parts Beginning Manufacturing Date: 4-01 (NG, LP) Exploded Parts Diagram Ending Manufacturing Date: 6-06 3 1 2 13 4 5 12 6 Log Set Assembly 9 7 10 11 8 Part number list on following page. 4 Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06
Resumo do conteúdo contido na página número 5
Service Parts List 6000TR-OAK, 6000TR-OAK-IPI IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order- ing, supply serial and model numbers to ensure correct service parts. ITEM COMMON PARTS SERIAL # PART NUMBER PRE 002324002 385-130 1Surround POST 002324002 2026-108 2 Hood SRV60-143-BK 3 Glass Door Assembly GLA-6TROC PRE 002324002 SRV383-338A 4 Burner NG, LP POST 002324002 SRV2025-007A 5 Log Grate 383-360A 6 Oak Log Set Assembl
Resumo do conteúdo contido na página número 6
6000TR-OAK-IPI Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: 6-06 3 Intermittent Pilot Ignition 13 Valve Assembly 10 12 11 9 1 2 6 8 4 7 5 ITEM DESCRIPTION SERIAL # PART NUMBER PRE 002324002 550-169 1 Valve Bracket POST 002324002 2025-101 2 Flex Ball Valve Assembly 302-320A 3 Ground Strap 2025-512 4 ON/OFF Rocker Switch 060-521A 5Valve NG 750-500 5 Valve LP 750-501 6 Burner Orifice NG (#37C) 582-837 6 Burner Orifice LP (#52C) 5
Resumo do conteúdo contido na página número 7
6000TR-OAK Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: 6-06 Standing Pilot Ignition 6 5 Valve Assembly 7 12 3 8 9 10 11 4 1 2 ITEM DESCRIPTION SERIAL # PART NUMBER 1 ON/OFF Rocker Switch 060-521A 2Valve NG 060-522 2 Valve LP 060-523 PRE 002324002 477-301A 3 Flexible Gas Connector POST 002324002 383-302A 4Wire Assembly 049-552A 5Pilot Assembly NG 485-510A 5Pilot Assembly LP 485-511A 6 Pilot Bracket 385-164 PRE 002324002 319
Resumo do conteúdo contido na página número 8
Approvals and Codes 1 High Altitude Installations Appliance Certification U.L. Listed gas appliances are tested and approved with- The Heat & Glo fireplace models discussed in this Installers out requiring changes for elevations from 0 to 2,000 feet in Guide have been tested to certification standards and listed the U. S. A. and in Canada. by the applicable laboratories. When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by Certifica
Resumo do conteúdo contido na página número 9
Inspection NOTE: The following requirements reference various The state or local gas inspector of the side wall horizontally Massachusetts and national codes not contained in vented gas fueled equipment shall not approve the installa- this document. tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with Requirements for the Commonwealth of the provisions of 248 CMR 5.08(2)(a)1 through 4. Massachusetts Exemptions The following equi
Resumo do conteúdo contido na página número 10
Getting Started 2 The Heat & Glo Warranty will be voided by, and Heat & Glo Introducing the Heat & Glo Gas Fireplaces disclaims any responsibility for, the following actions: Heat & Glo direct vent gas fireplaces are designed to oper- • Installation of any damaged fireplace or vent system ate with all combustion air siphoned from outside of the component. building and all exhaust gases expelled to the outside. • Modification of the fireplace or direct vent system. The information contained in th
Resumo do conteúdo contido na página número 11
28 1/2 [724mm] 14 1/4 [362mm] 21 1/2 [548mm] 8 [203mm] 11 5/8 [297mm] VENT COLLARS 8 ELECTRICAL [203mm] ACCESS VENT COLLARS GAS LINE ACCESS 34 5/8 38 25 1/4 [965mm] [879mm] [642mm] 26 7/8 2 1/8 3 1/2 [682mm] [55mm] [90mm] 36 1/8 [916mm] 12 3/4 [323mm] 6 7/8 [174mm] 41 [1040mm] TOP STANDOFFS TOP VENT COLLARS REAR VENT COLLARS HOOD TRIM DOOR RATING PLATE AND LABELS GAS LINE ACCESS GAS ELECTRICAL ACCESS CONTROLS Figure 1. Diagram of the 6000TR-OAK, 6000TR-OAK-IPI 11 Heat & Glo • 6000TR-OAK, 6000
Resumo do conteúdo contido na página número 12
1” MIN. (25mm) B A Installing the Fireplace 3 Constructing the Fireplace Chase A chase is a vertical box-like structure built to enclose the gas fireplace and/or its vent system. Vertical vents that run D E on the outside of a building may be, but are not required to be, installed inside a chase. C CAUTION: TREATMENT OF FIRESTOP SPACERS AND 1/2” MIN. (13mm) CONSTRUCTION OF THE CHASE MAY VARY WITH THE AB C D E TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT 42” 22” 36” 51” 72” SUBSTITUTES FOR THE RE
Resumo do conteúdo contido na página número 13
Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is CAUTION: MEASURE FIREPLACE DIMENSIONS AND set in place. Framing should be positioned to accommo- VERIFY FRAMING METHODS AND WALL COVERING date wall coverings and fireplace facing material. The dia- DETAILS BEFORE FRAMING. gram below shows framing reference dimensions. Framing should be constructed of 2 X 4 lumber or heavier. Noncombustible zone is defined by 3” above the elbow for the entire width and
Resumo do conteúdo contido na página número 14
DVP90ST 4 6 12 DVP4 DVP6 DVP12 14-1/4 12-3/16 2 MAX. MIN. 24 36 DVP12A 48 9-7/8 DVP24 O 45.0 10-1/4 DVP45 DVP36 11-1/4 7-1/4 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 4. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) 14 Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06
Resumo do conteúdo contido na página número 15
Step 3. Installing the Vent System A. Vent System Approvals Identifying Vent Components These models are approved to use DVP-series direct vent The vent systems installed on this gas fireplace may in- pipe components and terminations (see Figures 4 and 5). clude one, two, or three 90° elbow assemblies. The rela- Approved vent system components are labeled for identifi- tionships of vertical rise to horizontal run in vent configura- cation. This pipe is tested and listed as an approved com- t
Resumo do conteúdo contido na página número 16
Flue Restrictor Instructions CAP 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7). STRAIGHT UP VERTICAL VENTING V (FT.) 40' MAX. (12.4 M) V EXHAUST SHIELD NOTE: On vertical venting configurations over 10 feet install the flue restrictor (385-128). See flue restric- tor installation instructions. FLUE RESTRICTOR Figure 7 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figu
Resumo do conteúdo contido na página número 17
3. Match the amount of vertical you have in the sys- tem with the chart to find the appropriate position HORIZONTAL VENTING to set the Flue Restrictor (see Figure 9). Kit No. H Max. Run DVP-TRAP 24" (610 mm) - CHART - Top Vent Top Vent Rear Vent Rear Vent Vertical NG LP NG LP No No No 4' 1-1 Restrictor Restrictor Restrictor No 8' 2-2 1-2 1-1 Restrictor 15' 3-3 3-2 2-2 1-2 20' 3-4 3-3 3-3 2-3 25' 3-4 3-3 3-3 2-3 30' 4-4 3-4 3-4 3-3 H 90-DEGREE 35' 4-4 3-4 3-4 3-3 ELBOWS 40' 5-4 4-4 4-4 3-4 45-DEG
Resumo do conteúdo contido na página número 18
VENTING WITH ONE (1) 90° ELBOW V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) V NOTE: On vertical venting configurations, where the vertical component is over 10 feet, install the flue restrictor included in the manual bag assembly to improve flame appearance. H Figure 12. Venting with One 90° Elbow VENTING WITH ONE (1) 90° ELBOW
Resumo do conteúdo contido na página número 19
VENTING WITH TWO (2) 90° ELBOWS H 1 V H V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m) V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H1 = 20´ MAX. (6.2m) Figure 14. Venting with Two 90° Elbows o VENTING WITH TWO (2) 90 ELBOWS V FT. H + H (FT.) 1 1' MIN. (305mm) 5´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3.1m)
Resumo do conteúdo contido na página número 20
VENTING WITH THREE (3) 90° ELBOWS V H H + H 1 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m) V1+V+H+H1 = 40´ MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H1 = 20´MAX.(6.2 m) V 1 V H 1 H V H H + H + H 1 2 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´