Resumo do conteúdo contido na página número 1
Owner’s Manual & Installation Guide
READ THIS OWNER’S
MANUAL
Operate and maintain this gas heater
according to this instruction manual.
for the Tucson (8700) GAS-FIRED
Read This Manual In Its Entirety.
DIRECT-VENT HEATER
WARNING: If the information in these AVERTISSEMENT: Assurez-vous de bien
instructions is not followed exactly, a fire or suivre les instructions donné dans cett
Resumo do conteúdo contido na página número 2
HearthStone Quality Home Heating Products Inc Tucson Model #8700 HearthStone Quality Home Heating Products 2 317 Stafford Avenue, Morrisville, Vermont 05661 E-Mail: Inquiry@HearthStoneStoves.com
Resumo do conteúdo contido na página número 3
HearthStone Quality Home Heating Products Inc Tucson Model #8700 INFORMATION SHEET Record, on this page, all relevant information concerning the purchase, installation, and maintenance of your TUCSON Gas-Fired Direct-Vent heater. This information will facilitate servicing, purchase of replacement parts, and warranty claims (if necessary). Keep your original receipt in a safe place as proof of purchase. Serial Numbe
Resumo do conteúdo contido na página número 4
HearthStone Quality Home Heating Products Inc Tucson Model #8700 on/off cycling of the unit. At any time, you INTRODUCTION can override the thermostat with the Congratulations on your purchase of a On/Off/T’stat switch by setting it to “ON” Tucson Gas-Fired Direct-Vent heater. The or “OFF”. Tucson, by HearthStone, incorporates the latest in balanced vent gas technology, The Unit can also be equipped with an which wil
Resumo do conteúdo contido na página número 5
HearthStone Quality Home Heating Products Inc Tucson Model #8700 TABLE OF CONTENTS The installation must conform to local codes READ THIS OWNER’S MANUAL........ 1 or, in the absences of local codes, the current National Fuel Gas Code, ANSI Z223.1 (NFPA INTRODUCTION........................................... 4 54) or CAN/CGA B149 Installation Code. SAFETY INFORMATION............................... 5 (Installer l’appareil
Resumo do conteúdo contido na página número 6
HearthStone Quality Home Heating Products Inc Tucson Model #8700 the heater off and call a qualified service The unit should be cool prior to servicing technician. and cleaning. Any safety screen, guard, or The appliance and its individual shutoff valve component removed during servicing should must be disconnected from the gas supply be replaced prior to operation. Use of any piping system during any pressure testing of comp
Resumo do conteúdo contido na página número 7
HearthStone Quality Home Heating Products Inc Tucson Model #8700 WARNING: DO NOT OPERATE THE APPLIANCE WITH THE FRONT GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON. ONLY OPEN FRONT FOR ROUTINE SERVICE. DO NOT SLAM OR STRIKE GLASS. CERAMIC FIBER LOG SAFETY DO NOT LIGHT PILOT OR MAIN INFORMATION BURNERS BY HAND If the decorative ceramic log material T
Resumo do conteúdo contido na página número 8
HearthStone Quality Home Heating Products Inc Tucson Model #8700 MOBILE HOME INSTALLATIONS SERVICE CAUTION This appliance may be installed in an Any shield, door, or safety screen aftermarket, permanently located, component removed for servicing will be manufactured (mobile) home, where not replaced prior to operating. If you believe prohibited by local codes. your Tucson is not performing properly in any way what so ever,
Resumo do conteúdo contido na página número 9
HearthStone Quality Home Heating Products Inc Tucson Model #8700 SPECIFICATIONS: LISTED: DIRECT-VENT GAS HEATER Listed: Gas-Fired Direct-Vent Fireplace Heater Model: Tucson Direct-Vent Gas Fireplace Heater Testing Agency: Intertek Testing Services NA Inc. (ITS) Tested to: ANSI Z21.88-1998, CSA 2.33-M98, CAN/CGA2.17 Certified for Canada Approved for Mobile Home Installation (see page 7) Figure 1
Resumo do conteúdo contido na página número 10
HearthStone Quality Home Heating Products Inc Tucson Model #8700 overall efficiency of the unit as the heat OWNER’S INFORMATION from the pilot is wasted. When putting the The installation must conform with local unit back into service, follow the lighting codes or, in the absences of local codes, the instructions described on page 31. current National Fuel Gas Code, ANSI Z223.1 (NFPA 54) or CAN/CGA B149 Installation Wh
Resumo do conteúdo contido na página número 11
HearthStone Quality Home Heating Products Inc Tucson Model #8700 FIREBOX, PILOT, & BURNER TUBES The firebox should receive periodic cleaning to prevent the accumulation of dust, lint, and other debris. To clean the firebox, set the thermostat to the “OFF” position, and turn off the gas at the gas control valve. When the unit is cool, unfasten the front door and carefully remove the decorative ceramic fiber log set, tak
Resumo do conteúdo contido na página número 12
HearthStone Quality Home Heating Products Inc Tucson Model #8700 the gasket ends meet before trimming any excess. Do not overlap the gasket ends or leave ends with ragged edges. 7. Firmly and evenly press the gasket to seat it in its channel. CLASS CLEANING If operating with propane, it may be necessary to clean the inside of the glass occasionally. Do not use abrasive cleaners. Do not clean the glass when hot. All
Resumo do conteúdo contido na página número 13
HearthStone Quality Home Heating Products Inc Tucson Model #8700 INSTALLER’S INFORMATION ITEMS REQUIRED FOR CODES INSTALLATION Adhere to all local codes or, in their * External regulator (for propane/L.P.G. absence, the latest edition of THE only) NATIONAL FUEL GAS CODE ANSI * Piping which complies with local codes Z223.1 (NFPA 54) or CAN/CGA B149 * Pipe sealant approved for use with
Resumo do conteúdo contido na página número 14
HearthStone Quality Home Heating Products Inc Tucson Model #8700 dealer for replacement logs. Otherwise, set UNPACKING AND INSPECTION the logs aside until called for during the UNPACK AND INSPECT FOR DAMAGE installation. The Tucson is packaged by the manufacturer to withstand shipment without damage. HEARTH REQUIREMENT/FLOOR However, damage can occur during transit so take care to inspect for damage when PROTECTION
Resumo do conteúdo contido na página número 15
HearthStone Quality Home Heating Products Inc Tucson Model #8700 CLEARANCE TO COMBUSTIBLES Due to high surface temperatures, the unit should be located out of traffic and away from furniture and draperies. Clothing and other flammable material should not be placed on or near the heater. When positioning the unit always maintain adequate clearances around air openings into the combustion chamber and allow for adequate v
Resumo do conteúdo contido na página número 16
HearthStone Quality Home Heating Products Inc Tucson Model #8700 Figure 7: Snorkel-Wall Clearance To Combustibles Figure 6: Snorkel-Mantle Clearance To Combustibles 16
Resumo do conteúdo contido na página número 17
HearthStone Quality Home Heating Products Inc Tucson Model #8700 Acceptable Direct-Vent TERMINATION Cap locations. Figure 8 17
Resumo do conteúdo contido na página número 18
HearthStone Quality Home Heating Products Inc Tucson Model #8700 VENTING INFORMATION VENTING CONNECTION 1. The Tucson Direct-Vent is approved for installation only with the vent connecting components listed on this page. Use the following instructions along with the pipe manufacturer’s instructions to complete the installation. 2. Attach the inner starter collar and gasket to the unit with the eight # 8-32 x 3/
Resumo do conteúdo contido na página número 19
HearthStone Quality Home Heating Products Inc Tucson Model #8700 (refer to Figure 11 for proper adjustment RESTRICTION PLATE plate index location) ‘A’ in Figure 11 shows The restriction plate is used to control the the locating screw that determines the draft of the heater. Controlling the draft also position of the plate. changes the aesthetics of the flame. The restriction plate has eight settings, one (1) NOTE: Thes
Resumo do conteúdo contido na página número 20
HearthStone Quality Home Heating Products Inc Tucson Model #8700 Listed below are Simpson Dura-Vent, VENTING COMPONENTS & AmeriVent Direct, and Secure Vent CONFIGURATION components acceptable for installation, The Tucson cannot be vented jointly with along with the minimum venting kit any other solid fuel or gas appliance. It must available. The venting system must be be vented directly to the outside of the comprised