Resumo do conteúdo contido na página número 1
Installation & Operating Manual
The Harman Clarity 828i Gas Fireplace Insert
“Ce manuel est disponible en Français sur demande” R5
SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES
IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW
INSTALLAT
Resumo do conteúdo contido na página número 2
2 WARNING: If the information in this ADVETISSEMENT: Quinconque ne re- manual is not followed exactly, a fire or spect pas à la lettre les instructions dans le explosion may result causing property présent manuel risque de déclencher un damage, personal injury or loss of life. incendie ou une explosion entraíant des Installation and service must be performed dommages matérials, des lésions corporelles by a qualified installer, service agency, or ou la perte de vies humaines. Installation ou th
Resumo do conteúdo contido na página número 3
3 TABLE OF CONTENTS INTRODUCTION..................................................... 4 INSTALLATION ...................................................... 5 Clearances ........................................................... 5 Venting ................................................................ 6 Test for Flue Spillage .......................................... 6 ASSEMBLY................................................................ 7 Connecting to a Gas Supply ........................
Resumo do conteúdo contido na página número 4
4 Introduction Read these instructions carefully before you at- The Harman Clarity 828I Vented Gas Fireplace tempt to operate the heater. Failure to do so may Insert is a listed gas-fired vented room heater result in damage to property or personal injury tested by Intertek Testing Services/Warnock and may void the product warranty. Hersey to ANSI standard Z21.88-2002, CSA2.33- Consult with your local building code agency M02, and CAN/CGA-2.17-M91. and insurance representative before you begin Th
Resumo do conteúdo contido na página número 5
5 10" 10" Installation Due to high temperatures, the Clarity 828I Vented Gas Fireplace Insert should be located out of traffic and away from furniture and drap- eries. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully super- vised when they are in the same room as the Clearance from unit to sidewall or combustible Clarity 828I Fireplace Insert. trim Clothing or other flamm
Resumo do conteúdo contido na página número 6
6 Remove the chimney cap if one exists so that the DO NOT DISCONNECT OR BYPASS THE flue may be cleaned and the venting installed. VENT SAFETY SWITCH. Remove any existing hearth accessories such as WARNING: Operation of this heater when not glass doors, spark screens, andirons, and grates. connected to a properly installed and maintained Clean the chimney thoroughly to remove ash, soot, venting system or tampering with the vent safety and any obstructions, and then clean ash, soot, dust, shutoff
Resumo do conteúdo contido na página número 7
7 slightly and remove it Latch Assembly from the stove. Set the glass door aside in a The Clarity 828I Fireplace Insert comes with the safe place where it log set packed inside the firebox. The three trim will not be damaged. panels and two wing brackets are packed together WARNING: Do not in a separate carton. NOTE: The wing brackets abuse the glass on the must go on before the door. Clarity Fireplace Insert front by strik- Left Wing ing, slamming, or Bracket similar trauma. Do not operate thi
Resumo do conteúdo contido na página número 8
8 INSERT TO A GAS SUPPLY Burn Only the Fuel for Which the Heater is Equipped The Clarity Fireplace Insert will burn either natural gas or propane, but requires a dedicated burner system module for either fuel. The label on the burner system module indicates the fuel for which it is equipped. Making The Connection NATURAL Log Positions When Assembled PROPANE Install the center log so that it goes all the way to the back and is centered. When properly posi- The gas inlet is located at the bottom r
Resumo do conteúdo contido na página número 9
9 BEFORE OPERATING The Clarity Fireplace Insert, when installed, must be electrically grounded in accordance with local Gas Pressure Requirements codes or, in the absence of local codes, with the the Correct gas pressure and the use of a properly current edition of the National Electrical Code, sized gas supply line are essential for the safe and ANSI/NFPA 70 in the United States or the current efficient performance of this appliance. Make sure Canadian Electrical Code CSA 22.1 in Canada. that
Resumo do conteúdo contido na página número 10
10 panels first, using two 1/4-20 fasteners for each INTO THE FIREPLACE panel. Their mounting locations are near the top The Clarity Fireplace Insert has an integrated and bottom of the panel. draft hood, so a separate draft hood is not re- Install the top wing panel last using two 1/4-20 quired. fasteners. The mounting holes are near the inside Some fireplace openings may be large enough to edge of the side wing panels. connect the draft hood to the venting after the unit Before tightening, ma
Resumo do conteúdo contido na página número 11
11 Swing-out Label with Pilot Flames as Seen lighting instructions Through Hole in Left End of Log Flame Adjustment Levers HOW TO LIGHT THE FIRE 1. STOP! Read the safety information on the Use a glove to avoid contact if hot. For best results lighting instructions label on the stove. when fine-tuning the flame picture, initially leave 2. If using the optional thermostat, set thermo- the middle lever unchanged from its factory set- stat to the lowest setting. ting. Move the other two levers as
Resumo do conteúdo contido na página número 12
12 12. Place the ON-OFF/THERMOSTAT switch in in place by a magnet at the bottom and a magnet the ON position or in the THERMOSTAT position at the top. if the optional thermostat is used. Remove the left side trim panel first by pulling 13. Turn on the electric power to the heater. the top slightly away from the unit, and then 14. Set the optional thermostat to the desired lifitng. room temperature. The right side trim panel is removed in the same 15. Set the High-Low Regulator to desired set-
Resumo do conteúdo contido na página número 13
13 confirm that there is no blockage and that the system is in good repair. Directions for conducting a flue spillage test may be found on page 6. The vent manufacturer's instructions may provide specific suggestions or details on vent inspection. Any sections that are taken apart for the inspection must be reassembled and sealed as required. CLEANING THE GLASS The glass may be cleaned with ordinary house- hold glass cleaner and a soft cloth or paper towel. WARNING: Never clean the glass when it
Resumo do conteúdo contido na página número 14
14 Flame Adjusters Valve Arch Frame Thermostat Off Top Wing On Top Trim Panel Right Trim Panel Right Wing Right Trim Panel Optional Sunrise Gold Frame Right Wing Valve Door Cord Channel Screw Ait Inlet Grill (Remove to connect Blower Speed Switch thermostat) Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Resumo do conteúdo contido na página número 15
15 Appendix A: Fuel Conversion 6. Install the replacement module, re-install the logs, CONVERTING THE CLARITY FIREPLACE re-connect the wiring connections and gas line fit- INSERT FROM ONE GAS TO ANOTHER IN ting, secure the glass door, and replace the trim pan- THE FIELD els. After completing the fuel conversion, an installer NOTE: THE CONVERSION SHALL BE CAR- fuel label—supplied with the burner system mod- RIED OUT IN ACCORDANCE WITH THE RE- ule—must be filled out by the installer and attached Q
Resumo do conteúdo contido na página número 16
16 Appendix B: De-rating for High Altitude For high altitude installations above 1370 meters (4500 For U.S. installations, the Clarity Fireplace Insert feet), consult the local gas distributor or the authority is approved for elevations up to 2000 feet using the having jurisdiction for proper rating methods. factory-installed burner injectors. At elevations above 2000 feet, U.S. codes require a decrease in NOTE: The difference in altitude derating require- ments for the U.S. and Canada is simpl
Resumo do conteúdo contido na página número 17
17 Appendix C: Changing Orifices To change the orifices, such as when derating for 9. Remove the front burner. altitude, follow these steps. 10. Remove the 1/4-20 fasteners and retainer clip 1. Remove the side trim panels according to the that secure the rear burner, then remove the rear directions on page 12 to gain access to the levers burner. that secure the glass door, then remove the glass 11. Lift the rear air deflector straight up, and door according to the directions on page 7. rock i
Resumo do conteúdo contido na página número 18
18 Appendix D: Low Voltage Wiring Diagram 120 Volt Wiring Diagram The Clarity Fireplace Insert, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current edition of the National Electrical Code, ANSI/NFPA 70 in the United States or the current Canadian Electrical Code CSA 22.1 in Canada. Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Resumo do conteúdo contido na página número 19
19 Parts List The following replacement parts for your Harman Clarity Fireplace Insert are available from your Har- man dealer. 36. Burner Module (NG) 1-10-08700 1. Pilot NG 3-40-08229 Burner Module (LP) 1-10-08800 Pilot LP 3-40-08230 37. Gold Bars (2) 4-40-00141 2. Thermopile 3-20-08219 Bar Holders (Left) 2-00-446300-1 3. Pilot Tube 2-00-446118 Bar Holder (Right) 2-00-446300-2 4. Thermocouple 3-40-08228 38. Retainer Clips (2) 2-00-446322 5. Piezo Ignitor 3-40-08220 39. Blower As
Resumo do conteúdo contido na página número 20
20 Burner Assembly 34 32 31 33 30 27 29 28 2 1 7 6 3 8 5 9 4 10 11 12 14 15 13 26 17 16 25 23 20 22 19 24 18 21 Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.