Resumo do conteúdo contido na página número 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
ASCOT
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or
use any phone in your building.
• Immediately call your gas supplier
from a neighbour’s phone. Follow the
gas supplier’s i
Resumo do conteúdo contido na página número 2
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn
Resumo do conteúdo contido na página número 3
Table of Contents Safety Precautions....................................................................................................2 Table of Contents......................................................................................................3 Codes And Approvals.................................................................................................4 Specifications...........................................................................................................5
Resumo do conteúdo contido na página número 4
Codes And Approvals DIRECT VENT ONLY: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. ** TOP VENT DV ONLY** This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated inp
Resumo do conteúdo contido na página número 5
Specifications DIMENSIONS: � � � � � � � � � � � � � � � � � � � � � � � � � � � �� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �� 1 Height: 24 /16 inches (611 mm) 1 Width: 19 /16 inches (484 mm) � � � � � � � � � Depth: 15 5⁄8 inches (397 mm) � � � � � � � � � � � � �� � � � � � � �� Center of flue to ground without leveling legs: 18 3⁄8 inches (467 mm) Center of flue to ground with leveling legs (approx.): 19 inches
Resumo do conteúdo contido na página número 6
Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. LIGHTING INSTRUCTIONS: H o t w h i l e o p e r a t i n g . D o n o t t o u c h . K e e p c h i l d r e n , c l o t h i n g , C A U T I O N : f u r n i t u r e , g a s o l i n e o r o t h e r f l a m m a b l e v a p o r s a w a y . F O R Y O U R S A F E T Y : D o n o t o p e r a t e t h i s f i r e p l a c e w i t h t h e g l a s s r e m o v e d , c r a c k e d o r b r o k e n . R e p l a c e m e n t o f t h i s g l a s s sh
Resumo do conteúdo contido na página número 7
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating PILOT LIGHT: 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING. 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob
Resumo do conteúdo contido na página número 8
Maintenance And Service ROUTINE MAINTENANCE: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua
Resumo do conteúdo contido na página número 9
Maintenance And Service REPLACING GLASS: The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see PARTS LIST - COMPONENTS). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacement of
Resumo do conteúdo contido na página número 10
Maintenance And Service FUEL CONVERSION: TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result c
Resumo do conteúdo contido na página número 11
Maintenance And Service 7. Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 7. 5 b) Insert a /32” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 8), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt. L o o s e n T i g h t e n d) Flip the screw (refer to Figure 9). e) Using the Allen wrench as shown in Figure 8, rotate the screw clockwise
Resumo do conteúdo contido na página número 12
Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. PREPARATION FOR INSTALLATION: • Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible. • Before beginning, carefully check the glass door and the log set
Resumo do conteúdo contido na página número 13
Initial Installation QUALIFIED INSTALLERS ONLY PLANNING YOUR INSTALLATION: When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (25.4 cm), 11⁄2 inches (3.8 cm) clearance to combustibles must be maintained. Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine the le
Resumo do conteúdo contido na página número 14
Initial Installation QUALIFIED INSTALLERS ONLY VENT TERMINATION RESTRICTIONS: N O H D E B C B F i x e d B G C l o s e d L F i x e d O p e n a b l e F Cl o s e d G O p e n a b l e M J K B A I A T e r m i n a t i o n C a p A i r S up p l y I nl e t R e s t r i ct i o n Z on e G G a s M e te r ( Te r m i n a ti o n n ot a l l o w e d ) Figure 15. Vent Termination Restrictions, refer to Table 2. Table 2: Vent termination clearances, refer to Figure 15. 1 2 Letter Canadian Installation US Installati
Resumo do conteúdo contido na página número 15
Initial Installation QUALIFIED INSTALLERS ONLY FIREPLACE HORIZONTAL VENT KIT 50-1235: Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury. KIT COMPONENTS: Qnty Description Qnty Description 1 Horizontal direct vent termination cap 4 Wire spacers 1 Flue collar adapter 1 4 oz tube Mill-Pac Sealant 1 Wall thimble 1 4 oz tube RTV silicone 9 1 5’ (190 cm) length of Ø4” (10 cm) double walled fle
Resumo do conteúdo contido na página número 16
Initial Installation QUALIFIED INSTALLERS ONLY 10. Apply a bead of Mill-Pac Black sealant to H or i z o ntal V e n t T er m i n a t i on the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced. 11. Place a bead of high temperature silicone on the intake collar of the W a l l Fr am i ng fireplace, slide the Ø65
Resumo do conteúdo contido na página número 17
Initial Installation QUALIFIED INSTALLERS ONLY EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance. Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Tem
Resumo do conteúdo contido na página número 18
Initial Installation VENT RESTRICTOR SETTING: To access restrictor plate, look at the left hand rear corner of the unit. There is a small rectangular hole in the air jacket. Loosen the 1⁄4” hex head bolt and adjust to the correct setting. Slide the hex bolt to the next setting and retighten the bolt to ensure the plate does not move 1 5 ’ ( 4 . 5 7 m ) � � � � � � � � � � � 1 0 ’ ( 3 . 0 5 m ) � � � � � � � � � � � � � � � 1 2 3 4 5 5 ’ ( 1 . 5 2 m ) 1 5 2 3 4 5 � � � � � � � � � 4 � � � � � �
Resumo do conteúdo contido na página número 19
Initial Installation QUALIFIED INSTALLERS ONLY HORIZONTAL INSTALLATION: STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented t
Resumo do conteúdo contido na página número 20
Initial Installation QUALIFIED INSTALLERS ONLY STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 10” (25.4 cm) square hole (refer to Figure 22). The center of the square hole should match the center line of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the exterior wall where the vent will be terminated. Refer to Figure 15. If the wall being penetrated is constructed of non-combustible material i.e. masonry