Resumo do conteúdo contido na página número 1
VENTED PROPANE
GAS HEATERS
OWNER’S OPERATION AND INSTALLATION MANUAL
Models: CGB35P and CGB50P
WARNING: If the information in this manual WARNING: Improper installation,
is not followed exactly, a fire or explosion
adjustment, alteration, service, or
may result causing property damage, per-
maintenance can cause property
sonal injury, or loss of life.
damage, personal injury or loss of
FOR YOUR SAFETY
life. Refer to this manual for cor-
— Do not store or use gasoline or other
rect installation a
Resumo do conteúdo contido na página número 2
SECTION PAGE CONTENTS Safety Information......................................................................... 3 Product Identification .................................................................... 5 Local Codes ................................................................................... 6 Unpacking .................................................................................... 6 Product Features ............................................................................ 6
Resumo do conteúdo contido na página número 3
SAFETY WARNINGS IMPORTANT: Read this owner’s manual carefully and completely be- INFORMATION fore trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. DANGER Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the he
Resumo do conteúdo contido na página número 4
SAFETY WARNINGS Continued INFORMATION 7. Provide the following minimum heater clearances from combustibles (as viewed from the front of heater): Continued Front: 48 inches Back: 6 inches Top: 53 inches Right Side: 12 inches Left Side: 6 inches 8. Do not run heater • where flammable liquids or vapors are used or stored • under dusty conditions 9. Never place clothing or any flammable objects on the heater or venting system. 10. Heater and venting system surfaces are very hot during operation. Ke
Resumo do conteúdo contido na página número 5
PRODUCT Control Knob IDENTIFICATION Ignitor Button Lower Front Access Panel Figure 1 - Vented Propane Gas Heater Draft Hood Outlet for Venting System Control Valve Figure 2 - Vented Propane Gas Heater, Rear View 5 100352
Resumo do conteúdo contido na página número 6
Install and use heater with care. Follow all local codes. In the absence of local LOCAL CODES codes, use the latest edition of the following: • National Fuel Gas Code ANSI Z223.1, also known as NFPA 54 * • National Electrical Code ANSI/NFPA 70 * *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 1. Remove heater from carton. UNPACKING 2. Remove all protective packaging appli
Resumo do conteúdo contido na página número 7
LOCATING HEATER INSTALLING HEATER WARNING WARNING ICON G 001 Continued Maintain the minimum clearances shown in Figure 3, below. If you can, provide greater clearances. WARNING WARNING ICON G 001 Never install the heater • in a mobile home or a recreational vehicle. • where curtains, furniture, clothing, or other flam- mable objects are less than 48 inches from the front, 53 inches from the top, 12 inches from the right side and 6 inches from the left side and back of heater. • directly on car
Resumo do conteúdo contido na página número 8
VENTING HEATER INSTALLING Note: Venting/chimney materials are not supplied with heater. HEATER Continued WARNING A qualified service person must install the venting system for this heater. If venting system is not properly installed and maintained, the vent safety shut-off system will pre- vent the heater from running. Follow all local codes. WARNING This heater has a vent safety shut-off system. This system shuts off the heater gas supply if you do not vent heater properly or the venting syst
Resumo do conteúdo contido na página número 9
VENTING HEATER (continued) INSTALLING WARNING ICON G 001 WARNING HEATER Do not vent heater in any of the following ways (see Figure 4). Continued The vertical section of vent pipe must Heater must be vented to the out- extend at least two feet above the doors. Never vent heater to another highest point of any roof within ten room or inside a building. feet. Never extend vent pipe horizontally Never extend vent pipe horizontally through a chimney or flue. You must through outside wall
Resumo do conteúdo contido na página número 10
VENTING HEATER (continued) INSTALLING Proper Size Vent HEATER To safely vent heater, the vent connector pipe must be the same diameter as the draft Continued hood outlet on the rear of the heater. Pipe that is too small can cause flue gas to spill from the heater. Fasten vent connector to the draft hood outlet with a sheet metal screw. Vent Types Prefabricated or Masonry All-Fuel Chimney - This is a masonry chimney or a residential-type prefabricated chimney. Only use prefabricated chimneys list
Resumo do conteúdo contido na página número 11
CONNECTING TO GAS SUPPLY INSTALLING HEATER WARNING Continued A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 an
Resumo do conteúdo contido na página número 12
Installation must include a manual shutoff valve, ground joint union, plugged 1/8" INSTALLING NPT tap and a sediment trap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7). HEATER Continued Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. CAUTION Use pipe joint sealant that is resistant to liquid petro- leum (LP) gas. Instal
Resumo do conteúdo contido na página número 13
CHECKING GAS CONNECTIONS INSTALLING HEATER WARNING Continued Test all gas piping and connections for leaks after install- ing or servicing. Correct all leaks at once. WARNING Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. CAUTION Make sure external regulator has been installed be- tween propane supply and heater. See guidelines under Connecting to Gas Supply, page 11. Pressure Testing
Resumo do conteúdo contido na página número 14
INSTALLING GLASS PANEL INSTALLING 1. Locate the glass panel package inside the back of the heater. HEATER Continued WARNING ICON G 001 CAUTION Before installing glass panels, inspect the edges. If you notice any chips or cracks, do not install. If the surface on either side is deeply scratched, do not install. If these conditions exist, call DESA International’s Technical Ser- vice Department at 1-800-323-5190 for replacement glass panels. CAUTION WARNING ICON G 001 Do not operate heater withou
Resumo do conteúdo contido na página número 15
6. Insert top edge of glass panel into the upper glass retaining channel (see Figure 11). INSTALLING HEATER Hearth Continued Assembly Glass Panel Lower Front Access Area Figure 10 - Inserting Glass Panels CAUTION WARNING ICON G 001 Make sure you insert top edge of glass panels into the upper glass retaining channel. Do not install glass panels with top edge of glass in front of the upper glass retaining channel. Glass panels will not automatically go into the channel. You must guide the glass p
Resumo do conteúdo contido na página número 16
FRESH AIR FOR WARNING COMBUSTION This heater must have fresh air for proper operation. If not, poor fuel combustion and improper venting of flue AND gases will result. Carbon monoxide poisoning from VENTILATION backed-up flue gases could occur. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce hea
Resumo do conteúdo contido na página número 17
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION FRESH AIR FOR Example 1: Locating Heater in Unconfined (Open) Area COMBUSTION AND NOTICE An unconfined area has a minimum air volume of 50 VENTILATION cubic feet for each 1000 BTU/Hr input rating of all Continued appliances in the area (cubic feet equals length x width x height of area). Include adjoining rooms only if there are no doors between the rooms or if you add ventila- tion grills between the rooms (see Ventilating Confined Area, page 19).
Resumo do conteúdo contido na página número 18
Draft Hood Spillage: This is a hazardous situation. Draft hood spillage re- FRESH AIR FOR leases poisonous carbon monoxide gas into your home. COMBUSTION DANGER AND Carbon monoxide poisoning may lead to death! VENTILATION Continued If draft hood spillage occurs, check for blocked flue connectors, vent pipes, and chimneys. If you find blockage, remove. Test again for spillage. If spillage still occurs or there was no blockage, you need more fresh, outside air in the house. You must provide addit
Resumo do conteúdo contido na página número 19
Example 2: Locating Heater in Confined (Closed) Area FRESH AIR FOR COMBUSTION NOTICE A confined area has an air volume of less than 50 cubic AND feet for each 1000 BTU/Hr input rating of all appliances VENTILATION in the area (cubic feet equals length x width x height of Continued area). Include adjoining rooms only if there are no doors between the rooms. If you install this heater in a confined area, you must provide additional fresh air. Ventilating Confined Area This fresh air would come fro
Resumo do conteúdo contido na página número 20
OPERATING WARNING Heater and venting system surfaces are very hot during HEATER operation. Keep children and adults away from hot sur- faces to avoid burns and clothing ignition. Carefully super- vise young children when they are in the same room as heater. Heater will remain hot for a time after shut down. Let surface cool before touching. NOTICE If operating heater for the first time, a slight odor will occur. This odor will go away after a few hours of operation. FOR YOUR SAFETY READ BEFORE