Resumo do conteúdo contido na página número 1
READ AND SAVE THESE INSTRUCTIONS
™
SAVANNAH
Model No.
Ceiling Fan
CF716AW00
Owner's Manual
CF716GBZ00
CF716ORB00
Net Weight: 17.2 Lbs.
ENERGY STAR
CF716PW00
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty wi
Resumo do conteúdo contido na página número 2
WARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
Resumo do conteúdo contido na página número 3
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One 1/4” blade screwdriver One wire stripper One 5/16” open end wrench, or pliers Three wire connectors (supplied) WARNING ! MATERIALS Before assembly your ceiling fan, refer to section on Wiring outlet box and box connectors must be of
Resumo do conteúdo contido na página número 4
How to Put Your Ceiling Fan Together 1. Remove the hanger ball by loosening the setscrew 4. Make sure the grommet is properly installed in the in the hanger ball until the ball falls freely down the coupler cover, then slide the coupler cover on the downrod (Figure 1). Remove the pin from the downrod until it rests on the motor housing downrod, then remove the hanger ball. Retain the (Figure 3). pin and hanger ball for reinstallation in step 5. PIN HANGER BALL CEILING COVER DOWNROD DOWNROD GROMM
Resumo do conteúdo contido na página número 5
WARNING ! To reduce the risk of personal injury, do not bend the SWITCH HOUSING blade flange when installing the blade flanges, ASSEMBLY balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades. SWITCH HOUSING M5 x 6 WASHER CONNECTOR HEAD SCREW (3) LATCH MOTOR CONNECTOR Figure 7 MOUNTING SCREW FAN BLADE NOTE: Do not pinch wires between the switch BLADE FLANGE housing assembly and the switch housing plate. Figure 5 14. You have now completed the assem
Resumo do conteúdo contido na página número 6
How to Hang WARNING ! Your Ceiling Fan Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. WARNING ! NOTE: CEILING COVER, SUPPLY WIRES AND The fan must be hung with at least 7' of clearance OUTLET FAN WIRES OMITTED BOX from floor to blades (Figure 9). FOR CLARITY. CEILING HANGER BRACKET AT LEAST HANGER BALL/ 7' Figure 11 DOWNROD ASSEMBLY WARNING Figure 9 ! FLOOR To avoid possible fire or shock, do not pinch wires between the hanger ball/downro
Resumo do conteúdo contido na página número 7
NOTE: CEILING COVER BLACK AND BLUE OMITTED FOR CLARITY. SUPPLY Using Your Ceiling Fan FAN WIRES GROUND GROUND WIRE WIRE 1. Restore electrical power to the outlet box by turning LISTED the electricity on at the main fuse box. WIRE WHITE SUPPLY (NEUTRAL) CONNECTOR (3) 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air GREEN WIRE downward. If airflow is desired in opposit
Resumo do conteúdo contido na página número 8
Energy Efficient Use of Maintenance Ceiling Fans IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil- Periodic cleaning of your new ceiling fan is the only ing fan. Here are a few tips to ensure quality and maintenance that is needed. product performance. When cleaning, use only a soft brush or lint free cloth Choosing the Appropriate Mounting Location. to avoid scratching the finish. Ceiling fans
Resumo do conteúdo contido na página número 9
! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire switch wire connections in the switch housing. connections in the switch housing. ! WARNING: Make sure main
Resumo do conteúdo contido na página número 10
Repair Parts 2 1 3 5 6 4 7 8 19 11 10 18 17 16 12 15 14 13 9 U.L. Model No.: CF716 10
Resumo do conteúdo contido na página número 11
Repair Parts Listing Part Numbers Key Model No. Model No. Model No. Model No. No. Description CF716AW00 CF716GBZ00 CF716ORB00 CF716PW00 * Hanger Ball Assembly, 761655-21 761655-77 761655-32 761655-22 Consisting of: 1 Hanger Bracket — — — — 2 Hanger Ball — — — — 3 Downrod — — — — * Parts Bag Containing: 763738-1 763738 763738 763738 4 Wire Connector (3) — — — — 5 Threaded Stud (2) — — — — 7 Lockwasher (2) — — — — 8 Knurled Knob (2) — — — — 9 Coupling — — — — 10 Pin, Clevis — — — — 11 Clip, Hairpi
Resumo do conteúdo contido na página número 12
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73700000 Printed in China 11/08 Form No. BP7370 U.L. Model No.: CF716