Resumo do conteúdo contido na página número 1
Portable Evaporative Air Cooler
OWNER’S MANUAL
Read and save these instructions before use
Model: CL60PM
Voltage rating: 220-240V`50Hz
Power rating: 220W
For product inquiries or support, visit www.honeywellaircoolers.com
Or call Tel +44 (0) 1477 539 500 Fax +44 (0)1477 539 530
Email sales@scott-air-cooling.co.uk
Made in P.R.C.
Resumo do conteúdo contido na página número 2
This page is intentionally left blank
Resumo do conteúdo contido na página número 3
INDEX Read all instructions carefully before setting up and operating the unit, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION PAGE 1. THANK YOU ...................................................................................
Resumo do conteúdo contido na página número 4
THANK YOU THANK YOU! Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling performance from your unit, first fill it with water. Please read these instructions carefully. 2
Resumo do conteúdo contido na página número 5
USER TIPS COOL ~ EFFICIENT ~ NATURAL Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake.This breeze drops the temperature and has a relaxing cooling effect. The evaporative air cooler cools the air by means of the evaporation of water. When water evaporates into the air, the result is a mixture of air and water molecules. This chemical change requires heat which is taken from the water molecules, resulting in cooler air propelled from
Resumo do conteúdo contido na página número 6
USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow. The evaporative air cooler works best
Resumo do conteúdo contido na página número 7
SAFETY RULES READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: • Your cooler runs on 220-240 Volt AC, 50 Hz current. 220 -240Volt AC Check the household voltage to ensure it matches the 50 Hz appliance's rate specification. Before operating the product remove it from its packaging • and check it is in good condition. SHOCK HAZARD • DO NOT operate any product with a damaged cord or plug. We re
Resumo do conteúdo contido na página número 8
SAFETY RULES • DO NOT attempt repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire. • DO NOT operate with the Honeycomb media removed as this Water / Ice compartment will overload a
Resumo do conteúdo contido na página número 9
PARTS DESCRIPTION 1 Water Inlet 8 Water Level Indicator 2 Handle 9 Control Panel 3 Right Panel 10 Left Panel 4 Lever for Horizontal Louvres 11 Continuous Water Inlet 5 Water Tank 12 Drain Plug 6 Castors 13 Manual Water Inlet 7 Horizontal Louvres 14 Back Panel CONTROL PANEL 7
Resumo do conteúdo contido na página número 10
USE & OPERATION INSTALLING HOSE ADAPTER AND FLOAT VALVE • Connect the garden hose Connector and turn on the water. • Verify water tight connections by visually examining both the float/hose connections. Hose Connector FILLING WATER Water can be filled into the air cooler by Continuous water supply Connect a garden hose to the continuous water supply inlet. Manual operation Water can be poured into the unit from the back. Water compartment Water compartme
Resumo do conteúdo contido na página número 11
USE & OPERATION CONTROL KNOBS SPEED / ON - OFF Connect to the power supply and turn the Speed knob. The fan 0 3 2 will start. Change the speed from 1 for Low to 2 for Medium to 1 3 High. To switch OFF the unit turn the Speed know to "0". SPEED COOL Turn the Cool knob to ON to start the cooling. It takes a few OFF ON minutes to obtain the full effect from this mode. SWING COOL Vertical Louvres Turn the SWING knob to 'ON'. The louvres w
Resumo do conteúdo contido na página número 12
Resumo do conteúdo contido na página número 13
CLEANING & MAINTENANCE WARNING Before cleaning the unit, switch it to the ''OFF'' position • and remove the plug from the power socket. To clean the outside, use a damp cloth to remove dirt and • dust. Never use detergents, corrosive elements or any chemicals • to clean this product. When the product is not in use, store the unit in a dry place • out of direct sunlight.. CLEANING AND DRAINING THE WATER TANK To refill the tank during operation, turn the power ''OFF'' •
Resumo do conteúdo contido na página número 14
CLEANING & MAINTENANCE MAINTAING AND CHANGING THE HONEYCOMB The appliance is supplied with Honeycomb cooling media. • Draining the water reservoir and refilling with fresh water at • least once a week will greatly reduce mineral deposits in the pads and help to extend the life of Honeycomb cooling media. Do not run the unit in COOL mode with stale water in the tank. • It is recommended to empty the tank and refill it with fresh water if the water has been standing in the tank fo
Resumo do conteúdo contido na página número 15
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in Make sure cord is plugged in and try to turn the unit on by Power is not on pressing buttons on control panel or remote control. Pump is not turned on Turn on COOL function Low / No water Refill water tank Damaged pump R e p l a c e p u m p . C o n t a c t service centre When the product is used for Odour omission New unit the first time the Honeycomb
Resumo do conteúdo contido na página número 16
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Unit is making noise Calcium build up in blower Contact service centre. Pump will make noise if water Low or no water in the water level is near empty. Refill tank when COOL is selected water tank. Service Centre: Scott Brothers Limited 1 Whiteside, Station Road, Holmes Chapel, Cheshire CW4 8AA, U.K. Tel +44 (0)1477 539 500 Fax +44 (0)1477 539 530 Email sales@scott-air-c
Resumo do conteúdo contido na página número 17
TECHNICAL SPECIFICATIONS MODEL NO. CL60PM Voltage 220-240 V Frequency 50 Hz Wattage 220 Watts Water Tank Capacity 60 Litre Cooling Media Honeycomb Product Dimension 700 (L) x 466 (W) x 1017 (H) Net Weight 19 Kg Made in China ELECTRICAL WIRING DIAGRAM 14
Resumo do conteúdo contido na página número 18
Warranty Warranty on Honeywell Cooler We undertake by this Warranty to rectify free of charge any fault due to poor workmanship or faulty materials occurring in this Honeywell evaporative cooler within 1 year from the date of purchase. This undertaking is conditional upon the cooler being used only for personal domestic household or commercial purposes and installed and operated in accordance with our instructions and does not apply to consumable components such as cooling pads
Resumo do conteúdo contido na página número 19
This page is intentionally left blank
Resumo do conteúdo contido na página número 20
Autorised Distributor: Scott Brothers Limited IM01-1009-000-000 1 Whiteside, Station Road December 2009 Holmes Chapel © 2009 AirTek International Corporation Limited The Honeywell Trademark is used under license from Cheshire, CW4 8AA, U.K Honeywell International Inc. Tel +44 (0)1477 539 500 Honeywell International Inc. makes no representation or Fax +44 (0)1477 539 530 warranties with respect to this product. Manufactured