Resumo do conteúdo contido na página número 1
READ AND SAVE THESE INSTRUCTIONS
Model No.
CF701BS00
Brushed Steel
CF701ORB00
Oil Rubbed Bronze
™
BUILDER UNIPACK
CF701WW00
52” Ceiling Fan
Appliance White
Owner's Manual
Net Weight: 19.4 Lbs.
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it ap
Resumo do conteúdo contido na página número 2
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
Resumo do conteúdo contido na página número 3
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder Installed Wire Length Wire Size A.W.G. One 1/4” blade screwdriver One wire stripper Up to 50 ft. 14 50-100 ft. 12 MATERIALS WARNING ! Wiring outlet box and box connectors must be of type required by the local code. The minimum wire shall be Before assembling your ceiling fan, refer to section on a 3-condu
Resumo do conteúdo contido na página número 4
6. Mount the blade flanges to fan blades using three How to Put Your Ceiling M5 x 6mm washer head blade screws per blade Fan Together (Figure 2). 1. Pass the 42" motor leads through the opening in WARNING ! the ceiling cover. Be sure the cover is oriented correctly. To reduce the risk of personal injury, do not bend the 2. Separate, untwist and unkink the three motor blade flanges when installing the flanges, balancing leads. Route the motor leads through the hanger the blades, or cleaning the f
Resumo do conteúdo contido na página número 5
9. Remove the center plug screw from the switch 12. Engage the connector of the switch housing housing assembly (Figure 4). Remove and retain assembly with the motor connector (Figure 6). the two wire connectors. The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the SWITCH CUP CONNECTOR connectors latch closes properly. SCREWS 13. Carefully tuck all wires and splices into the switch housing. SWITCH HOUSING SWITCH ASSEM
Resumo do conteúdo contido na página número 6
15. Install two 60-watt (maximum) candelabra base Electrical Requirements light bulbs into the light fitter sockets (Figure 8). Your new ceiling fan will require a grounded electrical 16. Remove the finial nut and outer bowl cap from the supply line of 120 volts AC, 60 Hz, 15 amp circuit. light fitter (Figure 8). The outlet box must be securely anchored and 17. Pass the fan switch chain through the cut-slotted capable of withstanding a load of at least 50 pounds. hole in the bowl cap (Figure 8).
Resumo do conteúdo contido na página número 7
! WARNING ! WARNING The outlet box and joist must be securely mounted To avoid possible fire or shock, do not pinch wires and capable of supporting at least 50 lbs. Use only a between the hanger ball/downrod assembly and U.L. outlet box listed as “Acceptable for Fan hanger bracket. Support”. Wiring The Ceiling Fan ! WARNING To reduce the risk of fire, electric shock, or personal If you feel that you do not have enough electrical injury, mount fan to outlet box marked “Acceptable wiring knowledge
Resumo do conteúdo contido na página número 8
Using Your Ceiling Fan ! WARNING Check to see that all connections are tight, including 1. Restore electrical power to the outlet box by turning ground, and that no bare wire is visible at the wire the electricity on at the main fuse box. connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan 2. Check the operation of the light by gently pulling on damage could result. the light switch pull chain. 3. Check the operation of the fan by gently pulling on
Resumo do conteúdo contido na página número 9
Maintenance Accessories 1. Ceiling Fan/Light Controls (see store or catalog). IMPORTANT CARE INSTRUCTIONS 2. Downrod Extension Kits (see store or catalog). for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only ! WARNING maintenance that is needed. The use of any other control not specifically When cleaning, use only a soft brush or lint free cloth approved for this fan could result in fire, shock and to avoid scratching the finish. personal injury. Abrasive cleaning agents a
Resumo do conteúdo contido na página número 10
Repair Parts Listing Model No. Key No. Description CF701BS00 CF701ORB00 CF701WW00 * Hanger Pack Assembly, 760750-24 760750-48 760750-3 Consisting of: 1 Hanger Bracket — — — 2 Hanger Ball/ Downrod Assembly — — — 3 Ceiling Cover 763103-BS 763103-ORB 763103-WW 4 Light Fitter 763899 763899 763899 5 Glass Bowl 763900 763900 763900 6 Cover, Switch Housing 763098-BS 763098-ORB 763098-WW 7 Flange (Set of 5) 763102-BS 763102-ORB 763102-WW 8 Blade (Set of 5) 763100-13 763100-14 763100-7 * Parts Bag Contai
Resumo do conteúdo contido na página número 11
Repair Parts 1 14 2 3 9 15 16 10 11 18 4 22 8 17 6 5 7 19 21 20 12 12 13 13 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545. 11 U.L. Model No.: CF701
Resumo do conteúdo contido na página número 12
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. Form No. BP7392 Printed in China 02/09 8100 W. Florissant ¥ St. Louis, MO 63136 Part No. F40BP73920000 U.L. Model No.: CF701