Resumo do conteúdo contido na página número 1
Install guide 8035C
ENGLISH
Customer Support: 888-515-2585 or Visit our website www.ritetemp-thermostats.com
Printed in China
1-402-051
RESET
RESET
MENU
PROG
MENU
PROG
Resumo do conteúdo contido na página número 2
Install guide 8035C To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. Caution This can be done at the circuit breaker, or at the appliance. You will need #1 Phillips screwdriver (small) and Tools Drill with 3/16-in. (4.8mm) bit for this installation. 1 Location ï On replacement installations, mount the new thermostat in place of the old one if possible. ï On new Installations, follow the gui
Resumo do conteúdo contido na página número 3
A 2 Remove old unit PG 3 ï Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. ï Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side or front. These must be loosened. Note the letters printed near the terminals. ï Attach labels (enclosed) to each wire for identification. Read instructions carefully before removing any wiring from existing Caution thermostat. Wires must be la
Resumo do conteúdo contido na página número 4
PG 5 Rear View of control unit 4 Gas-Electric Selection REFER to the back of the Control Unit: ï If you have Electric Heat or a Heat Pump (without auxiliary heat) you must place the Gas/Electric jumper in the ELECT position (thermostat controls the Fan). ï If you have Gas Heat the Gas/Electric Jumper should be in the GAS position (furnace controls the Fan ). GAS ELECT 5 Install Batteries The 8035C requires batteries to operate your furnace and retain its programming in memory. S
Resumo do conteúdo contido na página número 5
PG 7 7 Wire Connections Make sure your wires are labeled. This is necessary to determine which step-by-step wiring diagram you should use. This may require you to find the 'other end' connection for each wire on your heating or air conditioning equipment and read the label there. If you have a Zoned Heating/Cooling system with multiple thermostats, please refer to our website at www.ritetemp-thermostats.com for installation notes or call 1-888-515-2585. Before you Connect Wires Please
Resumo do conteúdo contido na página número 6
If you do not find the wiring information for your system try our website at www.ritetemp-thermostats.com or Customer Support at 888-515-2585 7 Wire Connections cont When you have finished connecting the wires, close cover and attach control unit to wall unit. Hook the top Go To Page 15 of the body onto the base, swing the body down, and snap the body onto the base. Follow these procedures to verify you have 8 Check Unit correctly installed the unit. To check HEAT mode: ï Set the m
Resumo do conteúdo contido na página número 7
2 WIRE Heating (GAS MILLIVOLT or 24vac STEP 1 - Connect the R Thermostat (or RH) wire to the RH A terminal on the thermostat. This connects the Heater jumper wire Power to the thermostat. C R W STEP 2 - Connect the W wire to the W HEAT HEAT Power terminal on the thermostat. FURNACE This connects the heater control line to the thermostat. Your Heater is now connected to the thermostat. NOTE: Wires marked with the dotted line are optional. Return To Page 9 PG 11 3 WIRE Thermostat STEP 1
Resumo do conteúdo contido na página número 8
4 WIRE STEP 1 - Connect the Y wire Thermostat to the Y terminal on the A thermostat. This connects to the Cooler compressor. jumper wire STEP 2 - Connect the RH or R G C RH W Y wire to the RH terminal on the Cool Heat Heat FAN Comp thermostat. Power HVAC SYSTEM This connects the Heater/Cooler Power. STEP 3 - Connect the W wire to the W terminal on the thermostat. This connects to the heater control line. STEP 4 - Connect the G wire to the G terminal on the Thermostat. This conne
Resumo do conteúdo contido na página número 9
STEP 1 - Connect the G HEAT PUMP without auxiliary heat wire to the G terminal on the thermostat. jumper wire Thermostat This connects the Fan. A STEP 2 - Add a jumper wire between W and Y. jumper O or B wire STEP 3 - Connect the Y wire to the Y terminal on the R O or B Y G C thermostat. 24VAC Change Comp FAN This connects the Compressor. Power Over STEP 4 - Connect the O or B wire to the O or B Single Stage HEAT PUMP terminal on the thermostat. (If you have both O NOTE: Wires marke