Resumo do conteúdo contido na página número 1
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page -2 Wednesday, June 18, 2008 2:32 PM
7-day Programmable Hydronic Thermostat
AQ1000TP2
OWNER’S GUIDE
Place Bar Code Here
Resumo do conteúdo contido na página número 2
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page -1 Wednesday, June 18, 2008 2:32 PM IMPORTANT This thermostat is to be used with an AQ2000 Series hydronic control panel. Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. Read and save these instructions. ® U.S. Registered Trademark. Patents pending. © 6-08 Honeywell International Inc. All rights reserved. 69-2245EF
Resumo do conteúdo contido na página número 3
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 0 Wednesday, June 18, 2008 2:32 PM Table of contents User’s section About your new thermostat ........................................................................................................................ 1 Overview of display and controls................................................................................................................ 2 Powering up and setting the temperature .............................................
Resumo do conteúdo contido na página número 4
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 1 Wednesday, June 18, 2008 2:32 PM About your new thermostat Honeywell’s AQ1000TP2 is a programmable thermostat designed to be used with an AQ2000 Series hydronic control panel to operate a hydronic system, a HVAC system or both. It displays both indoor and outdoor temperatures and incorporates the following functions: A/F/AF regulation modes: The thermostat can control the ambient air temperature (A), the floor temperature (F) or the ambient a
Resumo do conteúdo contido na página número 5
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 2 Wednesday, June 18, 2008 2:32 PM Overview of display and controls Day Period Time Indoor temperature Menu button Clear button Outdoor temperature Fan On/Auto mode Fan button System button System Heat/Cool mode Hold/Run button Thermostat Hold/Run mode Cooling is on Heating is on Keypad is locked Temperature (up) and (down) buttons 2 69-2245EF
Resumo do conteúdo contido na página número 6
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 3 Wednesday, June 18, 2008 2:32 PM Powering up and setting the temperature Powering up The thermostat is powered through the AQ2000 hydronic control panel. It turns on when the zoning module is energized. At power-up, the message ALL ZONES SCHEDULE will flash for the first 15 seconds if the thermostat has been configured for ALL-ZONES scheduling (see page 19). In this case, at first power-up, the thermostat will adopt the schedule settings from
Resumo do conteúdo contido na página número 7
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 4 Wednesday, June 18, 2008 2:32 PM Setting the thermostat Hold/Run mode Select one of the following modes of operation: Run mode Place the thermostat in Run mode using the HOLD/RUN button. In this mode, the setpoint is automatically adjusted according to the schedule (see page 9). Hold Mode Place the thermostat in Hold mode using the HOLD/RUN button. In this mode, any modification to the temperature setpoint must be done manually. Temporary
Resumo do conteúdo contido na página número 8
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 5 Wednesday, June 18, 2008 2:32 PM Setting the system Heat/Cool mode Press the SYSTEM button to place the system in one of the following modes of operation: Cool mode The air cooling system is on. System mode indicator Heat mode SYSTEM button The hydronic heating system is on. Auto mode The system is in automatic changeover mode. This means the thermostat switches between heating mode and cooling mode to maintain the desired temperature. Cooling
Resumo do conteúdo contido na página número 9
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 6 Wednesday, June 18, 2008 2:32 PM Setting the fan On/Auto mode When the thermostat is used to operate a fan in an HVAC system, you can press the FAN button to place the fan in one of the two following modes of operation: On mode The fan runs all the time. Auto mode The fan runs only during a call for heat or cool. Fan mode indicator FAN button 6 69-2245EF
Resumo do conteúdo contido na página número 10
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 7 Wednesday, June 18, 2008 2:32 PM Setting the clock and date Press the or button to Press the Menu button. Press CLOCK. set the time (A). Press and hold the button to scroll faster. Press NEXT (B). 7 69-2245EF
Resumo do conteúdo contido na página número 11
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 8 Wednesday, June 18, 2008 2:32 PM Press the or button to Press the or button to Press the or button to set the year (A). Press NEXT set the month (A). Press NEXT set the day (A). Press the (B). (B). Menu button (B) to exit. NOTE: If you do not press any button for a period of 60 seconds, the thermostat will automatically end the clock and date programming after saving all modifications. 8 69-2245EF
Resumo do conteúdo contido na página número 12
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 9 Wednesday, June 18, 2008 2:32 PM Default schedule When the thermostat is set to Run mode, it automatically adjusts its temperature setpoint according to the programmed schedule. The schedule consists of 4 periods per day which represents a typical week day. You can program the thermostat to skip the periods that do not apply to your situation. For example, you can skip the Leave and Return periods for the weekend as in the AQ1000TP2 thermostat
Resumo do conteúdo contido na página número 13
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 10 Wednesday, June 18, 2008 2:32 PM New schedule You can program up to 4 periods (Wake, Leave, Return and Sleep) per day. To program a period, you need to set the start time, the heating setpoint and the cooling setpoint. You can have a different program every day. NOTE: The heating setpoint is always at least 2 °F (1 °C) lower than the cooling setpoint. For example, if the heating setpoint is at 77 °F (25 °C) and you lower the cooling setpoint
Resumo do conteúdo contido na página número 14
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 11 Wednesday, June 18, 2008 2:32 PM Modifying the schedule Select ALL DAYS** (A) or press Press the Menu button*. Press SCHEDULE. the or button to select the day (B). Press NEXT (C). * If ALL ZONES SCHEDULE appears, any modifications made to the schedule on this thermostat will be applied to other thermostats (see page 19). ** As soon as you select ALL DAYS, the displayed settings (start time, heating setpoint and cooling setpoint) will b
Resumo do conteúdo contido na página número 15
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 12 Wednesday, June 18, 2008 2:32 PM Press the or button NOTE: To erase the period’s Press the or button to to select the period (A). settings*, press the Clear button (A) set the start time (A). Press Press NEXT (B). once. Press Clear again to display and hold the button to scroll and select the period’s default faster. Press NEXT (B). settings. * To skip a period, erase the settings for that period. For example, if you wish to use the
Resumo do conteúdo contido na página número 16
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 13 Wednesday, June 18, 2008 2:32 PM Press the or button to Press the or button to If necessary, go back to step set the heating setpoint (A). set the cooling setpoint (A). 3 to set another day or step 4 Press NEXT (B). Press NEXT (B). to set another period. To exit, press the Menu button. NOTE: If you do not press any button for a period of 60 seconds, the thermostat will automatically exit the schedule programming after saving all mod
Resumo do conteúdo contido na página número 17
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 14 Wednesday, June 18, 2008 2:32 PM User’s configuration menu 1. Press the Menu button for 3 seconds to access the configuration menu. The first parameter is displayed. 2. To modify a parameter, press the or button. 3. To display the next parameter, press NEXT. 4. To exit the menu, press the Menu button. The parameters will appear in the order shown in the following table. Parameter descriptions can be found on page 15. Parameter Default sett
Resumo do conteúdo contido na página número 18
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 15 Wednesday, June 18, 2008 2:32 PM Temperature Display Mode Use this parameter to choose the temperature display mode. If the automatic mode (AU) is selected, the thermostat displays the temperature in the format specified in the AQ2000 control panel. If °F or °C is selected, the thermostat displays the temperature in the selected format, regardless of the format specified in the AQ2000 control panel. Temperature Setback Amount When the Unoccup
Resumo do conteúdo contido na página número 19
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 16 Wednesday, June 18, 2008 2:32 PM Permanent Backlight Use this parameter to select whether or not the thermostat’s screen is permanently illuminated. If you do not choose permanent backlight, the screen will lit for 12 seconds when any button is pressed. Time Display Format Use this parameter to select between the 12-hour format and the 24-hour format. Automatic Daylight Savings Time When Automatic Daylight Savings Time is enabled (On), the t
Resumo do conteúdo contido na página número 20
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 17 Wednesday, June 18, 2008 2:32 PM Alert messages The temperature measured by the thermostat is below the thermostat’s display range. The temperature measured by the thermostat is above the thermostat’s display range. The thermostat has lost communications with the AQ2000 control panel. The thermostat might be defective. The floor sensor may also be defective if the thermostat has been configured for F mode (see page 19). Cooling or heating has