Resumo do conteúdo contido na página número 1
TEC Electronic Computing Scale
SL-9000/9000N-FFR-US/CA/QR
Owner’s Manual
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Safety Summary Safety Summary Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautions necessary for safe handling are included in this manual. All warnings and cautions contained in this manual should be read and understood before handling or maintaining the equipment. Do not attempt to effect repairs or modifications to this equipment. If a fault occurs that cannot be rectified using the procedures described in this manual, turn off the power, u
Resumo do conteúdo contido na página número 4
Safety Summary Disconnect Disconnect If foreign objects (metal fragments, When unplugging the power cords, the plug. the plug. water, liquids) enter the machines, be sure to hold and pull on the plug first turn off the power switches and portion. Pulling on the cord portion disconnect the power cord plugs from may cut or expose the internal wires the outlet, and then contact your and cause fire or electric shock. authorized TOSHIBA TEC repre- sentative for assistance. Continued use of the
Resumo do conteúdo contido na página número 5
TABLE OF CONTENTS Page 1. INTRODUCTION ..................................................................................................... 1- 1 1.1 APPLICABLE MODEL ................................................................................... 1- 2 1.2 ACCESSORIES............................................................................................. 1- 2 2. SPECIFICATION ..................................................................................................... 2
Resumo do conteúdo contido na página número 6
Page 12. PROGRAMMED DATA VERIFICATION REPORTS..................................................12- 1 13. PASSWORD SECURITY..........................................................................................13- 1 13.1 SETTING PASSWORD AND PROTECT MENU .............................................13- 1 13.2 CALLING MENU BY ENTERING PASSWORD...............................................13- 3 14. OPERATING PROCEDURES.............................................................................
Resumo do conteúdo contido na página número 7
1. INTRODUCTION 1. INTRODUCTION 1. INTRODUCTION Thank you for purchasing the TEC SL-9000 Series electronic computing scale. As you will discover, the TEC SL-9000 has many features and functions designed for user friendliness as well as complete customer satisfaction. The 256 64 dot fluorescent display provides customers with ample information, the 140 speed keys realize a higher degree of operability, and the 3 inch/sec. print speed ensures fast and clear printing. Password security prevents u
Resumo do conteúdo contido na página número 8
1. INTRODUCTION 1.1 APPLICABLE MODEL 1.1 APPLICABLE MODEL • SL-9000-30M-N-FFR-US • SL-9000-15M-N-FFR-CA/QR • SL-9000-15M-FFR-CA/QR The description of the model number is as follows. SL-9000-30M-N-FFR-US Destination Code ex.) US,CA, QR, etc. Max. Capacity 30M: 30 lbs (decimal pound Keyboard Type /multi-interval) R: Remote keyboard 15M: 15 Kg (multi-interval) Display Type FF: Fluorescent full dot display N: LAN (Option) is available. Blank: LAN (Option) is not available. 1.2 ACCESSORIES Owne
Resumo do conteúdo contido na página número 9
2. SPECIFICATION 2.1 SCALE 2. SPECIFICATION 2.1 SCALE Item US CA QR Maximum Capacity 30 lb 15 Kg (30 lb) Minimum Scale Division 0.005 lb (0 - 15 lb.) 0.002 Kg (0 - 6 Kg) 0.005 Kg (6 - 15 Kg) 0.01 lb (15 - 30 lb.) 0.005 lb (0 - 15 lb) 0.01 lb (15 - 30 lb) Display Range 0 - 30.05 lb 0 - 15.025 Kg (0 - 30.05 lb) Maximum Tare 2.000 lb 1.000 Kg (2.205 lb) Unit Price Presettable $ 0.01 - 99.99 $ 0.01 - 99.99 0 - 99999 Minimum Price Display $ 0.01 $ 0.01 1 AC 120 V±10%, 60 Hz (US/CA type) Power Require
Resumo do conteúdo contido na página número 10
2. SPECIFICATION 2.2 OPTION 2.2 OPTION Model No. Option Name Description Source or Part No. LON Connector Part No. A modular connector used to connect scales to See TM8P-88P EAJ-0028001 each other in a LON configuration. Note 2 LON Terminal Part No. A modular resistor attached to the scales See Resistor 285D-8P EAJ-0029001 connected at both ends of the LON configuration. Note 2 LON Part No. An 8-pin telephone cable used with the LON See LON Cable 10319100003 connectors attached to both ends of t
Resumo do conteúdo contido na página número 11
3. APPEARANCE 3. APPEARANCE 3. APPEARANCE Display Operation Keyboard Label Guide Speed Keyboard and Programming Keyboard LAN Interface (SL9000N option) Drawer I/F LON I/F Label Guide Printer Cover Main Power Switch CMT/PL-3 I/F Level Gauge Adjustable Legs Meat Platter Power Cord RS-232C I/F: MALE TMCC I/F: MALE RS-232C I/F: FEMALE 3- 1
Resumo do conteúdo contido na página número 12
4. DISPLAY 4.1. US TYPE 4. DISPLAY 4.1 US TYPE WEIGHT e=d SCROLLING MESSAGE INDICATES SL-9000N SCALE AT ZERO CAPACITY 0 15 lb 0.005 lb 15 30 lb 0.01 lb 4.2 CA/QR TYPE WEIGHT e=d WEIGHT e=d SL-9000N 0 6 Kg 0.002 Kg 0 15 lbs 0.005 lbs CAPACITY CAPACITÉ 6 15 Kg 0.005 Kg 15 30 lbs 0.01 lbs NOTE: For the SL-9000 model, the model name on the display panel is “SL-9000”. 4- 1
Resumo do conteúdo contido na página número 13
5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD 5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD SET NEXT AUTO CLEAR SHIFT NEXT PLU CODE CHANGE DELETE RETURN SEND RECEIVE PLU PLU 1/4 DELETE INSERT DELETE PROG. ENTER TEST (A) (B) 1/2 1 ! # $ % & ? @ 1 2 3 4 5 6 7 8 9 0 * + ( ) / : ; < = > Q W E R T Y U I O P [ ` ] { : } A S D F G H J K L È É Â Ê Z X C V B N M SPACE , . ZERO FEED NOTE: Blank keys have no function. Programming Keyboard Function Name of Key Function 1. Clears numeri
Resumo do conteúdo contido na página número 14
5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD Name of Key Function 1. Displays the preceding PLU data. 2. Used to set an auto code. 3. Calls the preceding label format # when setting the print position. Moves the cursor to left. Moves the cursor to right. 1. Deletes a character selected by the cursor when setting the commodity name or DELETE message. (A) 1/2 2. Sets a unit price per 1/2 lb. 1. Inserts a space at the cursor position when setting the commodity name or INSERT message. 1 2. Sets a
Resumo do conteúdo contido na página número 15
5. KEY LAYOUT 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD CA,QR US type type (1) 1/2 100 g (2) 1/4 LB/kg 1 2 3 4 5 6 7 8 9 (1) ESC. PROG. POWER 10 11 12 13 14 15 16 17 18 (2) NEXT VOID PLU 19 20 21 22 23 24 25 26 27 PRESET SAVE FOR DT/TM COUNT 28 29 30 31 32 33 34 35 36 GRADE 7 8 9 LINE 37 38 39 40 41 42 43 44 45 LOGO 4 5 6 46 47 48 49 50 51 52 53 54 GROUP# 1 2 3 55 56 57 58 59 60 61 62 63 ST 0 T C 64 65 66 67 68 69 70 ZERO TEST FEED (4) PRT/* (3) NOTES:
Resumo do conteúdo contido na página número 16
5. KEY LAYOUT 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD Operation Keyboard Function Name of Key Function Prints the customer label. PRT/* Saves tare and unit price after taking off the commodity from a platter. SAVE Sets the number of articles in “BY COUNT” mode. FOR Displays the date. DT/TM NEXT Selects the item for change Print/OFF. PLU Corrects data just after the registration. VOID 1. Selects the speed key page. 2. Selects the function for change Print/OFF. Returns to the main menu. ESC. A
Resumo do conteúdo contido na página número 17
5. KEY LAYOUT 5.3 SELF SERVICE KEYBOARD Operation Keyboard Function Name of Key Function This key is used for item or subtotal discount by entering a percentage. % (Optional key by initial setting) Feeds the label. FEED Issues a test label. TEST Adjusts the zero point. ZERO Changes the label issue mode between Automatic issue and manual issue. AUTO/ MANUAL (Optional key by initial setting) Calls the PLU frequently used. 1 70 to 5.3 SELF SERVICE KEYBOARD NOTES: 1. When using the self service key
Resumo do conteúdo contido na página número 18
5. KEY LAYOUT 5.3 SELF SERVICE KEYBOARD (For Programming/Unit-Price Change/Read Reset/Security) Speed key can operate among unit-price change (prog-mod), read/reset-mode, security-mode. Of course panel-key can operate, those panel key don’t indicate top of key-sheet. NOTE: If you would like to switch the initial setting #13-2 to 1 please contact your authorized TOSHIBA TEC representative. 5- 6
Resumo do conteúdo contido na página número 19
6. PROCEDURE BEFORE OPERATION 6. PROCEDURE BEFORE OPERATION 6. PROCEDURE BEFORE OPERATION 1. Unpack the accessories and scale from the carton. 2. Install the remote unit on the scale. (See Page 7-1.) 3. Refer to Safety Precautions in this manual and set up the scale at a proper location. 4. Load the Label or Receipt. (See Page 9-1.) 5. Be sure to insert the Power Cord Plug into an AC outlet. 6. Adjust the Level Gauge. (See page 8-1.) 7. Connect a PC-AT Keyboard if necessary. 8. Turn the power
Resumo do conteúdo contido na página número 20
7. INSTALLATION PROCEDURE 7. INSTALLATION PROCEDURE 7. INSTALLATION PROCEDURE CAUTION: Never place the scale upside down. Doing so will cause an error in weigh operation. 1. Insert the attached remote bush into the remote pipe and push it up until it will go no further. 2. Assemble the remote unit and secure it using the four cap screws (C-5x25). 3. Insert two connectors into the scale unit. 4. Secure the remote blind plate using the two screws (B-4x8). 5. Attach the meat platter. Remote Unit