Resumo do conteúdo contido na página número 1
Instructions - Parts
Finex Airspray
312473B
Package Sprayer
ENG
Package solutions for pumping and spraying finishing materials. For professional use
only.
Important Safety Instructions
Read all warnings and instructions in this manual and in
your respective pump manual. Save these instructions.
Models:
289353 with Finex Airspray Gun
100 psi (7 bar, 0.7 MPa) Maximum Working Pressure
289354 with Finex HVLP Gun
100 psi (7 bar, 0.7 MPa) Maximum Working Pressure
TI10823A
Resumo do conteúdo contido na página número 2
Related Manuals Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Prime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Spraying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 G
Resumo do conteúdo contido na página número 3
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To h
Resumo do conteúdo contido na página número 4
Warnings WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. � Read MSDS’s to know the specific hazards of the fluids you are using. � Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. � Always wear impervious gloves when spraying or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating,
Resumo do conteúdo contido na página número 5
Installation Installation To maintain grounding continuity when flushing or Grounding relieving pressure: hold metal part of the spray gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve. Flush Before Using Equipment The equipment must be grounded. Grounding reduces The equipment was tested with water. To avoid contami- the risk of static and electric shock by providing an nating your fluid with water, flush the equipment with a escape wire for the el
Resumo do conteúdo contido na página número 6
Controls and Components Controls and Components Pump Operation and Repair Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts. Follow the Pressure Relief Procedure in your pump manual before cleaning or repairing your equipment. Sprayer Controls For complete instructions and warnings see your respec- � Pump air pressure regulator (C): a locking regula- tive pump manual. See Related Manuals, page 2. tor to adjust air press
Resumo do conteúdo contido na página número 7
Typical Installation Typical Installation True Earth Ground B I E M A F F H J C K D L G TI10825A FIG. 2: Typical Installation (Finex Airspray Gun Shown) Key: APump GHose Set B Bleed-type Master Air Line Shutoff Valve H Suction Hose C Pump Air Pressure Regulator I Pump Ground Wire (required) D Gun Air Pressure Regulator J Main Air Supply Line E Gun Fluid Pressure Regulator K Spray Gun, Finex Airspray or HVLP FAir Filter L Bleed Type Master Air Valve M Air Line Moisture Drain 312473B 7
Resumo do conteúdo contido na página número 8
Pressure Relief 3. Connect the gun fluid hose to fluid regulator. Tighten Pressure Relief securely. Follow pressure relief procedure when you stop spray- TI10829A ing and before cleaning, checking, or servicing the equipment. 4. Connect the fluid hose to the gun. Tighten securely. 1. Shut off the bleed-type air valve. TI10826A TI10831A - 5. Ground the pump. See Grounding, page 9. 2. Hold the gun firmly against a grounded metal pail and trigger the gun. TI10828A TI10824A 6. Connect the main a
Resumo do conteúdo contido na página número 9
Grounding 4. Turn off both air regulators. Grounding - - TI10836A Read Fire and Explosion Hazard. See page 3. 5. Open the bleed-type air valve. 1. Connect the ground wire clamp to a true earth ground. + TI10827A 6. Open the pump air regulator until the pump starts. TI10824A + 2. Ground the object being sprayed, fluid supply con- TI10836A tainer, and all other equipment in the spray area. 7. When clean solvent flows without air from the gun stop spraying. TI10832A TI10832A 3. Ground all solvent
Resumo do conteúdo contido na página número 10
Prime 7. Adjust the fluid pressure regulator. Prime + 1. Shut off both air regulators and the bleed-type air valve. TI10837A 8. Hold the gun firmly against a grounded metal pail - and trigger the gun until fluid flow is steady. Release - the trigger. The equipment is ready to spray. TI10826A TI10836A - 2. Shut off the fluid regulator. TI10828A - TI10837A 3. Install the air cap. TI10834A 4. Place the suction tube in the fluid. TI10832A 5. Open the bleed-type air valve. TI10827A + 6. Open the
Resumo do conteúdo contido na página número 11
Spraying Spraying Shutdown 1. Adjust fluid flow using the pump air regulator or the 1. Flush. See Flush page 9. fluid pressure regulator. 2. Relieve pressure. See Typical Installation, page 7. + TI10836A TI10837A 2. Adjust fluid pressure so stream from gun travels 6–8 in. straight before falling off. 6 in. to 8 in. TI10838A (152 mm to 203 mm) 3. Adjust the gun air regulator to achieve proper spray gun atomization. TI10836A + 4. Test the spray pattern. Read the fluid manufacturer’s recommendat
Resumo do conteúdo contido na página número 12
Maintenance 6. Clean the accessory air filter (not supplied) in your Maintenance main air line. Relieve pressure before servicing. See Typical TI10871A Installation, page 7. 1. Flush. See Flush, page 9. 2. Clean the air cap and fluid nozzle. TI10840A TI10834A 3. Clean the suction tube and inlet strainer, using a compatible solvent. TI10842A TI10841A 4. Clean the outside of the sprayer, using a soft cloth and compatible solvent. TI10823A 5. Check the hoses, tubes, and couplings every day. T
Resumo do conteúdo contido na página número 13
Troubleshooting Troubleshooting Relieve pressure before servicing. See Typical Installation, page 8. Problem Cause Solution Pump will not run, or stops. Air line valve shut off. Open valve. Clogged fluid line or spray gun. Clear, service. Do not allow fluid to setup in the pump and lines. Stuck or damaged pump air valve. Service pump. Use filtered air. Pump runs erratically. Clogged suction line or inlet strainer. Clear. Pump runs too fast. Exhausted fluid supply. Refill fluid supply and prime
Resumo do conteúdo contido na página número 14
Parts Parts 289353 with Finex Airspray Gun 289354 with Finex HVLP Gun 6 3 11 2 21 9 19 12 17 8 23 22a, 22b 10 16 1 18 7 25 24 15 13 5 4 TI10872A Ref. Part Description Qty. Ref. Part Description Qty. 17 590570 HOSE, polyethylene 4ft 1 289609 PLATE, mounting 1 18 116473 VALVE, vented 2 way 1 2 D31331 PUMP, diaphragm 1 19 237686 WIRE, ground assembly w/clamp 1 3 164856 FITTING, nipple, reducing 2 20 289522 HOSE, set, bundled (not shown) 25ft 4 15D921 LEG, right, (finished) 1 (289353) 5 15D922 LEG,
Resumo do conteúdo contido na página número 15
Dimensions Dimensions 19.19 in. (48.74 cm.) 12.02 in. (30.53 cm.) 19.26 in. TI10873A TI10874A (48.92 cm.) Technical Data Maximum fluid working pressure . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar) Operating temperature range . . . . . . . . . . . . . . . 40 -109 F (4.4 - 43 C) Package Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 19.8 lbs (9.0 kg) Wetted Parts Pump . . . . . . . . . . . . . . . .
Resumo do conteúdo contido na página número 16
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only