InfinitytAir Purifier
Sizes 1625 and 2025
Installation, Start---Up, and
Operating Instructions
NOTE: Read the entire instruction manual before starting the
install.
This symbol →indicates a change since the last issue.
TABLEOFCONTENTS
Page
INTRODUCTION .................................. 1
HOW IT WORKS .................................. 1
SAFETY CONSIDERATIONS ........................ 1
APPLICATION CONSIDERATIONS .................. 2
INSTALLATION ................................. 3--5
START-
Resumo do conteúdo contido na página número 2
Transitions APPLICATIONCONSIDERATIONS If the return air duct or furnace openings do not fit the Infinityt The Infinityt Air Purifier is designed for use in the return air Air Purifier cabinet openings, gradual transitions are duct of a forced air heating, cooling, and ventilation system. recommended to reduce air turbulence and maximize efficiency. Models GAPAAXCC1625 and GAPAAXCC2025 are No more than 20 degrees (about 4 in. per running ft) of specifically designed for use in systems with a forc
Resumo do conteúdo contido na página número 3
Step7—IdentifyMountingLocation INSTALLATION a. Identify a mounting orientation for the Infinityt Air Step6—CheckInfinitytAirPurifierComponents Purifier in the return air duct (see Fig. 3). b. Ensure airflow direction through the Infinityt Air Puri- ! CAUTION fier matches the arrows on the face of the air purifier cartridge. The Infinityt Air Purifier can be rotated 180 CUTHAZARD degrees to accommodate the cabinet orientation. Failure to follow this caution may result in personal injury. c. The l
Resumo do conteúdo contido na página número 4
a. Turn off power to the heating and cooling system. Step8—MounttheCabinet b. Remove the existing furnace filter and discard. Excessive system static may result if the Infinityt Air Purifier is used with other filtration devices. c. Remove the air purifier cartridge and enhancement ! WARNING module from the Infinityt Air Purifier cabinet. d. Position the cabinet between the furnace and return air ELECTRICALSHOCKHAZARD duct (see Fig. 3 and 4). A transition duct may be Failure to follow this warni
Resumo do conteúdo contido na página número 5
a. Ensure power has been removed from the heating and Furnace Adapters cooling system. b. Turn the Infinityt Air Purifier power switch off. c. Connect the power cord to the power supply connector (see Fig. 7). d. Route the power cord through nearest cabinet hole and protect with enclosed cable connector. Zip ties have been enclosed to secure the power cord to the side of the Airflow power supply. e. Attach the quick connect terminals to the furnace EAC--1 and EAC--2 spade connections. Attach the
Resumo do conteúdo contido na página número 6
O C S IHI/LOR IDM PL3 1 HSIR 1 PL2 IDR L1 ACRDJ PL1 1 1 2 3 ON PLT OFF W2 Y1 DHUM G COM WW1 Y/Y2 R HI HEAT LO HEAT 24V U T A T Power Cord Sample Furnace Circuit Board to EAC Terminals LHT OFF DLY Use cable connector to secure power cord to cabinet Power Supply Connector Power Supply Connector TEST/TWIN Use terminals to connect the power cord wires to the furnace HUM 0.5-AMP024 VAC Power Supply EAC-1 & 2, & ground terminals Power Cord FUSE 3-AMP SEC-1 SEC-2 EAC-2 TERMINAL Use wire ties to
Resumo do conteúdo contido na página número 7
Step2—Turn the Infinityt Air Purifier switch to the off position. ! WARNING Step3—Remove the Infinityt Air Purifier door. ELECTRICALSHOCKHAZARD Step4—Slide out the old air purifier cartridge and discard. Failure to follow this warning could result in personal injury Step5—Install the new air purifier cartridge. or death. NOTE: Make sure that the arrows on the air purifier cartridge The following procedures will expose electrical components. Disconnect power between checks and proceed point towar
Resumo do conteúdo contido na página número 8
Table2—SpecificationsandDimensions Specifications GAPAAXCC1625 GAPAAXCC2025 Color Taupe Metallic Taupe Metallic CabinetMaterial 20 Ga. Powder Coated Steel 20 Ga. Powder Coated Steel Electrical 115v/60 Hz (from furnace EAC terminals) 115v/60 Hz (from furnace EAC terminals) Maximum Airflow (CFM) 1600 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 ReplacementCartridge GAPCCCAR1625 GAPCCCAR2025 Dimensions GAPAAXCC1625 GAPAAXCC2025 A 18---3/8 21---7/8 B 15---1/8 18---5/8 C 11---1/8 11---
Resumo do conteúdo contido na página número 9
CARRIER CORPORATION FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER: FIRST: Contact the installer. You may find their name on the furnace or in your Homeowner’s Packet. If the installer’s name is not known, call your builder or home retailer if yours is a new residence. SECOND: Contact the nearest distributor. (See telephone yellow pages.) THIRD: Contact: Carrier Corporation Consumer Relations P.O. Box 4808 Syracuse, New York 13221 Phone: 1-800-428-4326 Model No. _________
Resumo do conteúdo contido na página número 10
Printedin China Edition Date: 3/06 Copyright 2005 Carrier Corp.S 7310 W.Morris St.S Indianapolis,IN 46231 Catalog No: GAPA---2SI Replaces: GAPA---1SI Manufacturerreservestherighttochange,atanytime,specificationsanddesignswithoutnoticeandwithoutobligations. 10 GAPA