Resumo do conteúdo contido na página número 1
Quality Refrigeration
OWNER’S MANUAL
Instructions for the proper installation, operation, care
and maintenance of all Traulsen VPS* Pizza Prep Tables
*U.S. Patent No. 6,089,036
Standard 12” Front to Back Rail Models
VPS48S, VPS54S, VPS66S, VPS72S, VPS90S & VPS114S
Jumbo 20” Front to Back Rail Models Models
VPS54J, VPS66J, VPS72J, VPS90J & VPS120J
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers, and heated
cabinets this way as a matter of pride.
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS I. The Serial Tag Page 1 VII. Service & Maintenance Information a-Cleaning The Condenser Page 6 II. Receipt Inspection Page 2 b-Light Bulb Replacement Page 6 c-Gasket Replacement Page 6 III. Installation d-Door & Hinge Removal Page 6 a-Location & Clearance Page 2 e-Front Work Surface Removal Page 7 b-Power Supply Page 2 f-Defrost Timer Page 7 c-Packaging Page 2-3 g-Temperature Control Page 7-8 d-Installing Supports Page 3 h-Service Information Page 8 e-Installing The Optional T
Resumo do conteúdo contido na página número 3
II. RECEIPT INSPECTION II. RECEIPT INSPECTION III. INSTALLATION (cont’d) All Traulsen products are factory tested for performance III. a – LOCATION & CLEARANCE (cont’d): and are free from defects when shipped. The utmost care has been taken in crating this product to protect against damage in transit. Casters or legs are boxed inside to prevent damage. Upon delivery carefully inspect your Traulsen unit for shipping damage. If any is detected, note it on the carrier’s Bill Of Lading and save a
Resumo do conteúdo contido na página número 4
III. INSTALLATION (cont’d) III. c - PACKAGING (cont’d): III. e - INSTALLING THE OPTIONAL TICKET RAIL: then slide the pallet out from under it. DO NOT LAY Supplied standard with jumbo rail models only. Use of THE UNIT ON ITS BACK, FRONT OR SIDE. the ticket rail is optional and not required. Insert the vertical legs of the ticket rail into the two receptacles NOTE: The front work surface of all Jumbo Rail located on the rear of the cabinet (see figure 5). models can be removed if necessary to
Resumo do conteúdo contido na página número 5
IV. FIRST TIME START-UP V. DAILY OPERATION If this equipment has been stored or shipped in an V. a - PANS: ambient colder than room temperature, YOU MUST Standard rail VPS models are designed to operate with ALLOW THE COMPRESSOR TO WARM UP TO ROOM full, half or third size pans without the use of adapter TEMPERATURE PRIOR TO CONNECTING TO THE bars. Other fractional size pans can be used with POWER SUPPLY. This could take several hours. optional adapter bars available from Traulsen. (see sectio
Resumo do conteúdo contido na página número 6
VI. ROUTINE CLEANING Use only cleaning products designed for use on stainless steel in conjunction with the proper tools to retain the like-new appearance of your Traulsen refrigeration product. Occasional use of a commercial stainless steel polish, such as “Sheila Shine,” will help protect the stainless steel surface. Follow the directions on the spray can for proper use. VI. a - CLEANING THE RAIL AREA: VI. b - CLEANING THE CABINET (cont’d): Remove all food pans and rail inserts for cleaning
Resumo do conteúdo contido na página número 7
VII. SERVICE & MAINTENANCE INFORMATION VII. a - CLEANING THE CONDENSER: VII. d - DOOR & HINGE REMOVAL: Clean the condenser at least monthly (more often if Remove the hinge cover from both hinges. On the lower necessary) to insure long service life. Keeping the hinge insert a 3/32” pin punch into one of the holes in condenser free of lint and dust will allow the the spring retainer. Rotate the retainer clockwise refrigeration system to operate at peak efficiency and slightly and remove the loc
Resumo do conteúdo contido na página número 8
VII. SERVICE & MAINTENANCE INFORMATION (cont’d) VII. e - FRONT WORK SURFACE REMOVAL : VII. f - DEFROST TIMER: To facilitate transport through narrow doorways all In normal operation the defrost timer only needs to be Jumbo Rail VPS models are supplied standard with a set on startup and after each power loss. Rotate the removable front work surface (see figure 10). small knob (near the outer edge of the large dial) clockwise until the correct time of day on the large dial WARNING: Excess weight
Resumo do conteúdo contido na página número 9
○○ VII. SERVICE & MAINTENANCE INFORMATION (cont’d) VII. g - TEMPERATURE CONTROL (cont’d): VII. g - TEMPERATURE CONTROL (cont’d): With the switch in the UNLOCK position, the settings STEP 4- Press the SET key again to access the can be checked (or changed) in four simple steps cooling/heating mode. The LCD will display the using the LCD display and the three keys on the current mode. Pressing the up and down arrow keys control face. will toggle between C1 and H1. Factory setting is C1. Press t
Resumo do conteúdo contido na página número 10
VIII. TROUBLE SHOOTING GUIDE OPERATIONAL SYMPTOM POTENTIAL CAUSE/REMEDY 1.Unit fails to start. a. Unit unplugged, breaker tripped or fuse blown. b. Switch in OFF position. 2. Interior compartment is too warm. a. Door(s) open. b. Warm product recently loaded. c. Door gaskets damaged or worn. d. Pan(s) missing. 3. Condensation on the exterior surface. a. Condensation on the exterior surface of the unit is perfectly normal during periods of high humidity. b. Door(s) misaligned or gas
Resumo do conteúdo contido na página número 11
X. PAN CAPACITIES X. a - THE VPS SYSTEM: The Venturi Plenum System (VPS) pizza prep tables are designed to keep all foods fresh, at an even temperature, without freezing. The VPS system accomplishes this task by surrounding product with cold air top to bottom and on all sides without drying the ingredients. This extends shelf life, eliminating the need to stir products or rotate pans. It has the added benefit of eliminating cleanup associated with the frost and condensation found in “wrapped rai
Resumo do conteúdo contido na página número 12
XI. SPARE/REPLACEMENT PARTS LISTING XI. a - SPARE/REPLACEMENT PARTS LIST FOR ALL STANDARD RAIL VPS PIZZA PREP TABLE MODELS: Part Description VPS48S VPS54S VPS66S VPS72S VPS90S VPS114S Door Gasket 341-60070-00 341-60070-00 341-60050-00 341-60050-00 341-60050-00 341-60050-00 Door - Hinged Left 200-60150-00 200-60150-00 200-60144-00 200-60144-00 200-60144-00 200-60144-00 Door - Hinged Right 200-60151-00 200-60151-00 200-60145-00 200-60145-00 200-60145-00 200-60145-00 Temperature Control 403-130-103
Resumo do conteúdo contido na página número 13
XII. ADAPTER BAR CHART (not shown to scale) p/n 8700226 p/n 6084006 Horizontal Support For Standard Rail Models Only Vertical Support For Standard Rail Models Only p/n 7000070A p/n 7000071A Vertical Support For Jumbo Rail Models Only Horizontal Support For Jumbo Rail Models Only p/n 8700008 p/n 7000204 Horizontal Support For Jumbo Rail Models Only Horizontal Support For Jumbo Rail Models Only -12-
Resumo do conteúdo contido na página número 14
XIII. WARRANTY INFORMATION STANDARD DOMESTIC WARRANTY TRAULSEN warrants new equipment to the original purchaser, when installed within the United States against defective material and workmanship for one (1) year from the date of original installation. Under this warranty, TRAULSEN will repair or replace, at its option, including service and labor, all parts found to be defective and subject to this warranty. The compressor part is warranted for an additional four (4) years. During this period
Resumo do conteúdo contido na página número 15
XIV. INDEX A O Adapter Bars 12 Operating Guidelines 9 Overshelves, Installing The Optional 3 B P C Packaging 2 Casters, Installing 3 Pans 4 Cleaning, All 5-6 Pan Capacities 10 Clearance 2 Parts, Replacement List 11 Cord & Plug 4 Power Supply 2 Power Switch 4 D Defrost Timer 4, 7 R Door, Removal 6 Return Authorization 2 Rail Cover, Sliding 5 E Rail, Closing Down At Night 4 Rail, Setting Up The 4 F Freight Damage 2 S Serial Tag 1 G Shelf Pins 5 Gasket, Replacement 6 Shelves, Installing 3, 10 Sprin
Resumo do conteúdo contido na página número 16
HOURS OF OPERATION: Monday thru Friday 7:30 a.m. - 4:30 p.m. CST Traulsen 4401 Blue Mound Road Fort Worth, TX 76106 Phone: (800) 825-8220 Fax-Svce: (817) 740-6757 Website: www.traulsen.com Quality Refrigeration © 2005 Traulsen - All Rights Reserved