Resumo do conteúdo contido na página número 1
Wine Storage Installation Guide
Resumo do conteúdo contido na página número 2
WINE STORAGE Contents Important Note 3 Wine Storage To ensure this product is installed and operated as safely and efficiently as possible, take note of the following types 4 Model 424G / 424FSG Site Preparation of highlighted information throughout this guide: 7 Model 424G / 424FSG Installation IMPORTANT NOTE highlights information that is especially 11 Model 427G / 427RG Site Preparation important. 14 Model 427G / 427RG Installation CAUTION indicates a situation where minor injury or produ
Resumo do conteúdo contido na página número 3
WINE STORAGE Product Information Tools and Materials Important product information including the model and • Screwdrivers—standard, Phillips and Torx. serial number are listed on the product rating plate. For • Power drill. undercounter models, the rating plate is located on the • Drill bits (masonry bits required for concrete installation). underside of the top wall. For full-size models, it is attached to the underside of the control panel. Refer to the illustra- • Standard socket a
Resumo do conteúdo contido na página número 4
MODEL 424G / 424FSG SITE PREPARATION Opening Dimensions MODELS 424G AND 424FSG DUAL INSTALLATION When installing two units side by side in a dual installa- tion, the opening width is determined by adding the single opening widths together. 24" (610) OPENING Dual installation kits are available through an authorized DEPTH Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. For ques- tions regarding the installation, call Sub-Zero custom
Resumo do conteúdo contido na página número 5
MODEL 424G / 424FSG SITE PREPARATION Electrical Preparation Installation must comply with all applicable electrical codes. To operate properly, the door must open a minimum of 90°. Use a minimum 3" (76) filler in corner installations to assure The electrical supply should be located within the shaded a 90° door opening. area shown in the illustration below. A separate circuit, servicing only this appliance is required. A ground fault cir- Uncrate the unit and inspect for damage. Remove and
Resumo do conteúdo contido na página número 6
MODEL 424G / 424FSG SITE PREPARATION Anti-Tip Bracket MODEL 424FSG WARNING 5 To prevent the unit from tipping forward, the anti-tip The back of the anti-tip bracket must be installed 24 /8" bracket must be installed. (625) from the front and centered behind the unit. Refer to the illustration below. Refer to page 13 for wood and con- crete floor applications. MODEL 424G The anti-tip bracket should be attached to the wall behind 1 the unit with the bracket flange located /4" (6) above the top
Resumo do conteúdo contido na página número 7
MODEL 424G / 424FSG INSTALLATION Custom Panel MODEL 424G To mount the custom panel, open the door and use pre- drilled holes to position the panel. Drive screws into the For overlay applications, a custom door panel must be panel through black tape on the door frame. Screw holes installed. Panel size is critical for a proper fit. To verify panel are hidden behind the door gasket. Use as many screws as requirements and dimensions, refer to the Sub-Zero design necessary to secure the custom
Resumo do conteúdo contido na página número 8
MODEL 424G / 424FSG INSTALLATION Placement Alignment LEVELING CAUTION Before moving the unit into position, secure the door Level the unit before sliding it into position. Turn each of the closed and protect any finished flooring. four leveling legs clockwise to raise the unit and counter- clockwise to lower. Refer to the illustration below. Use an appliance dolly to move the unit near the opening. DOOR ADJUSTMENT If the unit has been on its back or side, it must stand upright The top and bo
Resumo do conteúdo contido na página número 9
MODEL 424G / 424FSG INSTALLATION Completion Plug the power cord into the grounded outlet, then slide ANCHORING the unit into position. Verify the anti-tip bracket is properly To anchor, use the countertop bracket provided to secure engaged. the unit to the underside of the countertop. Refer to the 1 It may be necessary to install the unit /4" (6) beyond the illustration below. If the countertop bracket can not be front surface of adjacent cabinetry, to prevent interference utilized, install
Resumo do conteúdo contido na página número 10
MODEL 424G / 424FSG INSTALLATION Door Clearance FULL-SCALE TEMPLATE To allow for a 145° door opening, the unit should extend 1 a minimum of /4" (6) beyond the front surface of adja- cent cabinetry. The unit can be installed flush, however, there is potential for interference with the panel if the door is opened past 90°. UNDERCOUNTER ADJACENT UNIT CABINETRY DOOR CLOSED 1 /2" (13) 3 /4" (19) DOOR PANEL 1 /4" (6) 1 /8" (3) HINGE DETENT AT 145° OPENING (DOOR OPENS PAST 145°) 0" 1" (25) SCAL
Resumo do conteúdo contido na página número 11
MODEL 427G / 427RG SITE PREPARATION Opening Dimensions MODELS 427G AND 427RG DUAL INSTALLATION When installing two units side by side in a dual installa- tion, the opening width is determined by adding the single opening widths together. A dual installation kit is required, 25" (635) OPENING but does not affect the opening width. DEPTH Dual installation kits are available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, s
Resumo do conteúdo contido na página número 12
MODEL 427G / 427RG SITE PREPARATION Electrical Preparation Installation must comply with all applicable electrical codes. Uncrate the unit and inspect for damage. Remove the wood base and discard shipping bolts and brackets. Remove and The electrical supply must be located within the shaded recycle packing materials. Do not discard the kickplate, anti- area shown in the illustration below. A separate circuit, ser- tip bracket and hardware. vicing only this appliance is required. A ground faul
Resumo do conteúdo contido na página número 13
MODEL 427G / 427RG SITE PREPARATION Anti-Tip Bracket WOOD FLOOR WARNING To prevent the unit from tipping forward, the anti-tip After properly locating the anti-tip bracket in the opening, 3 bracket must be installed. drill pilot holes /16" (5) diameter maximum in the wall studs or wall plate. Use the #12 screws and washers to secure the brackets. Verify the screws penetrate through the flooring The back of the anti-tip bracket must be installed 24" (610) material and into wall studs or wal
Resumo do conteúdo contido na página número 14
MODEL 427G / 427RG INSTALLATION Anti-Tip Bracket Custom Panels CONCRETE WEDGE ANCHOR INSTALLATION For models 427G and 427RG, custom panels and handle hardware must be installed. Stainless steel panels are 3 1 Drill a /8" (10) diameter hole any depth exceeding the available through an authorized Sub-Zero dealer. For local minimum embedment. Clean the hole or drill additional dealer information, visit the find a showroom section of our depth to accommodate drill fines. website, subzero.com.
Resumo do conteúdo contido na página número 15
MODEL 427G / 427RG INSTALLATION Panel Installation The custom overlay door panel is attached using screws DRAWER PANELS (MODEL 427RG) provided through the door frame. Screw locations are Remove the mounting hardware attached to the front of the marked on the back of the custom panel using tenon cen- unit and set aside. Place the panel face down on a pro- ters inserted into holes of the door frame. tected work surface. With the unit secured and door closed, hold the custom Position the top ed
Resumo do conteúdo contido na página número 16
MODEL 427G / 427RG INSTALLATION Placement Alignment LEVELING CAUTION Before moving the unit into position, secure the door/ Once the unit is in position, height adjustment can be made drawers closed and protect any finished flooring. from the front. Using a standard screwdriver, turn front leveling legs clockwise to raise the unit or counterclockwise to lower. Using a Phillips drive, turn rear adjustment screws Use an appliance dolly to move the unit near the opening. clockwise to raise th
Resumo do conteúdo contido na página número 17
MODEL 427G / 427RG INSTALLATION Completion TRIM INSTALLATION KICKPLATE INSTALLATION Install decorative trim strips to the top and sides of the unit. Install the kickplate using the screws provided. The Attach the top trim using the double-sided velcro, then snap mounting bracket may be adjusted slightly for a flush fit. The side trim over brackets on the sides of the unit. Refer to the kickplate must be removable for service. The floor cannot illustration below. interfere with removal. Refer
Resumo do conteúdo contido na página número 18
MODEL WS-30 SITE PREPARATION Opening Dimensions STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW 3 83 /4" W (2127) OPENING WIDTH OPENING HEIGHT SIDE VIEW FRONT VIEW NOTE: Shaded line represents profile of unit. If two units are installed side by side, refer to page 20. OPENING WIDTH W 1 WS-30 29 /2" (749) 18 | Sub-Zero Customer Care 800.222.7820
Resumo do conteúdo contido na página número 19
MODEL WS-30 SITE PREPARATION Opening Dimensions FLUSH INSET INSTALLATION 3 26 /16" (665) FLUSH 3 INSET 2 /16" DEPTH (56) FINISHED CLEATS* TOP VIEW 1 1 1 /4" /4" (32) (6) 84" W (2134) FLUSH INSET WIDTH FLUSH INSET HEIGHT 1 1 /4" (32) 4" (102) 3 2 /16" 3" (56) (76)* TYPICAL SIDE VIEW FRONT VIEW *3" (76) typical depth. Shaded areas will be visible and should be finished to match cabinetry. 3 NOTE: Shaded line represents profile of unit with /4" (19) panel. 3 Dimensions assume a /4" (19) panel thick
Resumo do conteúdo contido na página número 20
MODEL WS-30 SITE PREPARATION Opening Dimensions DUAL STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW 3 83 /4" W (2127) OPENING WIDTH OPENING HEIGHT SIDE VIEW FRONT VIEW NOTE: Shaded line represents profile of unit. A dual installation kit will be required for this installation. OPENING WIDTH W 3 WS-30 and 30" Built-In Model 59 /4" (1518) 3 WS-30 and 36" Built-In Model 65 /4" (1670) 20 | Sub-Zero Customer Care 800.222.7820