Resumo do conteúdo contido na página número 1
On-Premise
Laundry
Planning
Handbook
TMB1268C
TMB1268C
120 and 170 Pound Tumblers
Starting Serial No. 0907003062
Refer to Installation manual for full instructions.
3-09-71R5
August 2011
Resumo do conteúdo contido na página número 2
Tumblers – 120 and 170 ..................................................................... 2 Table of Introduction...................................................................................... 2 Model Identification .................................................................. 2 Contents Specifications and Dimensions ........................................................ 4 120 Pound Tumbler Dimensions and Exhaust Outlet Locations 5 170 Pound Tumbler Dimensions and Exhaust Outle
Resumo do conteúdo contido na página número 3
Tumblers – 120 and 170 Introduction TMB1268C TMB1268C Model Identification Gas Steam/Thermal Oil IPD120G2-IT120L IPD120G2-IT120N IPD120S2-IT120S IPD120S2-IT120T 120 Pound IPD170G2-IT170L IPD170G2-IT170N IPD170S2-IT170S IPD170S2-IT170T 170 Pound Includes models with the following control suffixes: RD – reversing DMP OPL RE – reversing LED OPL RQ – reversing dual digital timer 3-09-71 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 2
Resumo do conteúdo contido na página número 4
Tumblers – 120 and 170 1 1 TMB2288N 120 POUND TUMBLER 170 POUND TUMBLER TMB2288N 1 Serial Plate Conversion Table Multiply By To Obtain Multiply By To Obtain Btu 0.252 kCal Pounds/sq. inch 0.06895 Bars Btu 1055 Joules Pounds/sq. inch 0.070 kg/sq. cm Inch 25.4 Millimeters Pounds (lbs.) 0.454 Kilograms Inches W.C. 0.036 Pounds/sq. inch Boiler Horsepower 33,479 Btu/hr. Inches W.C. 0.249 kPa Boiler Horsepower 34.5 lbs. steam/hr. 2 lb./inch (psi) 6.895 kPa CFM 0.471 liters/second 3 ft. 28.32 Liters kW
Resumo do conteúdo contido na página número 5
Tumblers – 120 and 170 Specifications and Dimensions Specifications 120 Pound 170 Pound 66 dBA 66 dBA Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor. 44 x 41 50.75 x 42.5 Cylinder Size: (1118 x 1041) (1289 x 1080) Inches (mm) 120 170 Cylinder Capacity dry weight: (54.4) (77.1) Pounds (kg) 0.75 0.75 Cylinder Motor Horsepower 13 Fan Motor Horsepower 10 12 Air Outlet Diameter: (254) (300) Inches (mm) 0.3 0
Resumo do conteúdo contido na página número 6
Tumblers – 120 and 170 120 Pound Tumbler Dimensions and Exhaust Outlet Locations TOP VIEW OF EXHAUST DUCT W X V H I U B A Y Z C F D E G TMB2326N TMB2326N Cabinet Dimensions Models A B C D E F G H I 31.38 in. 32.5 in. 48.91 in. 49.91 in. 67.92 in. 45.38 in. 46.38 in. 85.7 in. 70 in. 120L/N (797 mm) (826 mm) (1242 mm) (1268 mm) (1725 mm) (1153 mm) (1178 mm) (2177 mm) (1778 mm) 31.38 in. 32.5 in. 48.91 in. 49.91 in. 67.92 in. 45.38 in. 46.38 in. 83.5 in. 70 in. 120S (797 mm) (826 mm) (1242 mm) (
Resumo do conteúdo contido na página número 7
Tumblers – 120 and 170 170 Pound Tumbler Dimensions and Exhaust Outlet Locations TOP VIEW OF EXHAUST DUCT X W Y H I B V A C F D E G TMB2327N TMB2327N Cabinet Dimensions Models A BCD E F G H I 33.86 in. 32.5 in. 50.75 in. 51.75 in. 68.85 in. 52.12 in. 53.12 in. 94 in. 75.12 in. 170L/N/S (860 mm) (826 mm) (1289 mm) (1314 mm) (1749 mm) (1324 mm) (1349 mm) (2388 mm) (1908mm) Refer to Position and Level the Tumbler to temporarily reduce the heights of these models. Exhaust Outlet Dimensions and Lo
Resumo do conteúdo contido na página número 8
Tumblers – 120 and 170 Electric and Gas Connection Locations for Gas Models A C A C D B B D 120L/N 170L/N TMB2255N Electrical Connection Gas Connection Models A B C D Diameter 18.34 in. 77.84 in. 12.5 in. 70.5 in. 3/4 in. NPT 120L/N (466 mm) (1977 mm) (318 mm) (1791 mm) 21 in. 81 in. 14.85 in. 77.4 in. 1 in. NPT 170L/N (533 mm) (2057 mm) (377 mm) (1966 mm) NOTE: These figures are approximate dimensions only. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 3-09-71 7
Resumo do conteúdo contido na página número 9
Tumblers – 120 and 170 Electric and Steam Connection Locations for Steam Models A1 A2 A1 A2 C C B2 B1 B2 B1 F E E F D D 120S 170S TMB2256N Steam Inlet Models Diameter A1 A2 F 3/4 in. NPT 35.875 in. 13.375 in. 82.75 in. 120S (911 mm) (340 mm) (2102 mm) 3/4 in. NPT 37.625 in. 15.25 in. 88 in. 170S (956 mm) (387 mm) (2235 mm) Steam Outlet Models Diameter B1 B2 D 3/4 in. NPT 34.625 in. 13.125 in. 68.5 in. 120S (879 mm) (333 mm) (1740 mm) 1 in. NPT 44.625 in. 8.75 in. 71.75 in. 170S (1133 mm) (222 m
Resumo do conteúdo contido na página número 10
Tumblers – 120 and 170 Installation Pre-Installation Inspection Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered. Remove the crate and protective cover as soon as possible and check the items listed on
Resumo do conteúdo contido na página número 11
Tumblers – 120 and 170 Tumbler Enclosure WARNING To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustible construction must conform to the minimum clearances. W056R1 3 1 2 4 5 6 TMB2020N 7 8 TMB2020N NOTE: Shaded areas indicate adjacent structure. 1 0.5 in. (13 mm) recommended between machines for removal or installation. 2 Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece may be used to conceal the open
Resumo do conteúdo contido na página número 12
Tumblers – 120 and 170 Make-up air openings for a room containing Exhaust Requirements tumbler(s) and/or gas fired hot water heater or other gravity vented appliances must be increased WARNING sufficiently to prevent downdrafts in any of the vents when all tumblers are in operation. Do not locate A drying tumble dryer produces gravity vented appliances between tumbler(s) and combustible lint. To reduce the risk of fire, make-up air openings. If it is necessary to duct make- the tumble dr
Resumo do conteúdo contido na página número 13
Tumblers – 120 and 170 NOTE: Exhaust ducts must be constructed of sheet Duct Equivalent Length of metal or other noncombustible material. Such Diameter Rigid Straight Duct ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel 6 in. (152 mm) One 90° elbow = 7 ft. (2.1 m) not less than 0.0195 inches (0.495 mm) thick. Local 8 in. (203 mm) One 90° elbow = 9.3 ft. (2.83 m) codes may require additional thickness. 10 in. (254 mm) One 90° elbow = 11.
Resumo do conteúdo contido na página número 14
Tumblers – 120 and 170 3 4 2 1 5 TMB2103N TMB2103N 1 Removable strip of panel in framing wall to permit removal of tumbler from framing wall 2 Partition or bulkhead 3 Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm) 4 2 in. (51 mm) minimum clearance on both sides of duct 5 Exhaust airflow – maximum length of duct: 14 ft. (4.3 m) Figure 2 NOTE: Do not install wire mesh or screen in NOTE: Inside of duct must be smooth. Do not use exhaust duct openin
Resumo do conteúdo contido na página número 15
Tumblers – 120 and 170 Manifold Venting NOTE: Never connect a tumbler duct at a 90° angle to the collector duct. Refer to Figure 3. Doing While it is preferable to exhaust tumblers individually so will cause excessive back pressure, resulting in to the outdoors, a main collector duct may be used if it poor performance. Never connect two tumbler is sized according to Figure 4 and Figure 5. This exhaust ducts directly across from each other at the illustration indicates minimum diameters,
Resumo do conteúdo contido na página número 16
Tumblers – 120 and 170 1 2 LK J I H G F E DC B A 3 ONE MANIFOLD ASSEMBLY TMB2019N 1 NOTE: Where the exhaust duct pierces a 2 Outlet Duct Diameter combustible wall or ceiling, the opening 3 45° Typical MUST be sized per local codes. Figure 4 120 Pound 170 Pound Duct Station 10 in. (254 mm) Duct 12 in. (305 mm) Duct 10 in. (254 mm) 12 in. (305 mm) A 15 in. (381 mm) 17 in. (432 mm) B 18 in. (457 mm) 21 in. (533 mm) C 21 in. (533 mm) 24 in. (610 mm) D 24 in. (610 mm) 27 in. (686 mm) E 26 in. (660
Resumo do conteúdo contido na página número 17
Tumblers – 120 and 170 1 2 L LK I I J K J CONTINUE CONTINUE TO A TO A 3 TWO MANIFOLD ASSEMBLIES TMB2018N TMB2018N 1 NOTE: Where the exhaust duct pierces a 2 Outlet Duct Diameter combustible wall or ceiling, the opening 3 45° Typical MUST be sized per local codes. Figure 5 120 Pound 170 Pound Duct Station 10 in. (254 mm) Duct 12 in. (305 mm) Duct 15 in. (381 mm) 17 in. (432 mm) A 21 in. (533 mm) 24 in. (610 mm) B 26 in. (660 mm) 30 in. (762 mm) C 30 in. (762 mm) 34 in. (864 mm) D 33 in. (838
Resumo do conteúdo contido na página número 18
Tumblers – 120 and 170 serial plate for most current specifications of Electrical Requirements product being installed. Refer to Table 5. NOTE: Use copper conductors only. NOTE: Minimum wire sizes are obtained from NOTE: 3 Phase Only– Each tumbler must be Canadian Electrical Code and are intended for use connected to its own individual branch circuit as a guideline only. Electrical connections should be breaker, not fuses, to avoid the possibility of “single made only by a qualified elect