Resumo do conteúdo contido na página número 1
T20 / T30 / T50 / T75
Installation/Operator Manual
WARNING: For your safety the information AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
in this manual must be followed to
notice pour réduire au minimum le risque
minimize the risk of fire or explosion and
d’incendie ou d’explosion ou pour éviter
to prevent property damage, personal
tout dommage matériel, toute blessure ou
injury or death.
la mort.
— Do not store or use gasoline or other
—Ne pas entreposer ni uti
Resumo do conteúdo contido na página número 2
Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation. Only qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer. The following “FOR YOUR SAFETY” caution must be posted near the dryer i
Resumo do conteúdo contido na página número 3
IMPORTANT Table of Contents ________ You must disconnect and lockout the electric supply and the gas supply or the steam supply Safety Precautions ................................4 before any covers or guards are removed from the machine to allow access for cleaning, T20 Specifications ................................6 adjusting, installation, or testing of any equipment T30 Specifications ................................8 per OSHA standards. Please observe all safety precautions displayed T50 S
Resumo do conteúdo contido na página número 4
A program should be established for the inspection and Safety Precautions ____________________ cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection Warning and cleaning can best be determined from experience at For your safety, the information in this manual ! each location. must be followed to minimize the risk of fire or Do not operate steam dryers with more than 150 psi (10.34 explosion and to prevent property damage, perso
Resumo do conteúdo contido na página número 5
The “cool down” cycle of tumble dryers should be used to reduce the temperature of the items. They should not be NOTES ______________________________________________________ removed from the tumble dryer or piled or stacked while hot. Fabric softeners or similar products should not be used in a _____________________________________________________________ tumbler dryer to eliminate the effects of static electricity unless this practice is specifically recommended by the manufacturer _________
Resumo do conteúdo contido na página número 6
T20 Specifications __________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 20 lb 9.07 kg TUMBLER DIAMETER 25-3/4” 65.41 cm TUMBLER DEPTH 24” 60.96 cm TUMBLER VOLUME 7-1/2 cu ft 212.38 L 0.19 kW TUMBLER/DRIVE MOTOR 1/4 hp 0.25 kW BLOWER/FAN MOTOR 1/3 hp DOOR OPENING (DIAMETER) 19-3/8” 49.21 cm DOOR SILL HEIGHT 13” 33.02 cm WATER CONNECTION 3/4”-11.5 NH (North America) 3/4” B.S.P.T. (Outside North America) DRYERS PER 20’/40’ CONTAINER 42 / 84 DRYERS PER 48’
Resumo do conteúdo contido na página número 7
T20 Specifications __________________________________________________________________ 113429-9 Telephone 01422 822282 7
Resumo do conteúdo contido na página número 8
T30 Specifications __________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 30 lb 13.61 kg TUMBLER DIAMETER 30” 76.20 cm TUMBLER DEPTH 27” 68.58 cm TUMBLER VOLUME 11.04 cu ft 312.62 L 0.19 kW TUMBLER/DRIVE MOTOR 1/4 hp BLOWER/FAN MOTOR 1/2 hp 0.37 kW DOOR OPENING (DIAMETER) 19-3/8” 49.21 cm DOOR SILL HEIGHT 14-7/8” 37.78 cm WATER CONNECTION 3/4”-11.5 NH (North America) 3/4” B.S.P.T. (Outside North America) DRYERS PER 20’/40’ CONTAINER 12 / 28 DRYERS PER 48
Resumo do conteúdo contido na página número 9
T30 Specifications __________________________________________________________________ 113429-9 Telephone 01422 822282 9
Resumo do conteúdo contido na página número 10
T50 Specifications __________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 50 lb 22.68 kg TUMBLER DIAMETER 37” 93.98 cm TUMBLER DEPTH 25-3/4” 65.41 cm 453.64 L TUMBLER VOLUME 16.02 cu ft 0.56 kW TUMBLER/DRIVE MOTOR 3/4 hp 0.37 kW BLOWER/FAN MOTOR 1/2 hp DOOR OPENING (DIAMETER) 27-3/8” 69.53 cm DOOR SILL HEIGHT 16” 40.64 cm WATER CONNECTION 3/4”-11.5 NH (North America) 3/4” B.S.P.T. (Outside North America) DRYERS PER 20’/40’ CONTAINER 10 / 22 DRYERS PER 48
Resumo do conteúdo contido na página número 11
T50 Specifications __________________________________________________________________ 113429-9 Telephone 01422 822282 11
Resumo do conteúdo contido na página número 12
T75 Specifications __________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 75 lb 34.02 kg TUMBLER DIAMETER 37” 93.98 cm TUMBLER DEPTH 35-1/2” 90.17 cm TUMBLER VOLUME 22.09 cu ft 625.52 L TUMBLER/DRIVE MOTOR 3/4 hp 0.56 kW 0.37 kW BLOWER/FAN MOTOR 1/2 hp 69.53 cm DOOR OPENING (DIAMETER) 27-3/8” DOOR SILL HEIGHT 16” 40.64 cm WATER CONNECTION 3/4”-11.5 NH (North America) 3/4” B.S.P.T. (Outside North America) DRYERS PER 20’/40’ CONTAINER 9 / 20 DRYERS PER 48’
Resumo do conteúdo contido na página número 13
T75 Specifications __________________________________________________________________ 113429-9 Telephone 01422 822282 13
Resumo do conteúdo contido na página número 14
Installation Procedures _______________ Unpacking/Setting Up _________________ Installation should be performed by competent professional Remove protective shipping material (i.e., plastic wrap and in accordance with local, state, and country codes. In the optional shipping box) from the dryer. absence of these codes, the installation must conform to Important applicable American National Standards: ANSI Z223.1-LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70- Dryer must be transport
Resumo do conteúdo contido na página número 15
Domestic Type I (T20, T30, T50 Only) A = 6-inches (15.24 cm) A = 10-inches (25.4 cm) B = 24-inches (60.96 cm) B = 11-inches (27.94 cm) EXAMPLE: For a bank of 4 T30 dryers, 2 unrestricted openings measuring 10-inches by 11-inches (25.4 cm by 27.94 cm) are acceptable. EXAMPLE: For T50, 2 unrestricted openings measuring Important 6-inches by 24-inches (15.24 cm by 60.96 cm) are acceptable. Make-up air must be free of dry cleaning solvent ! If a closet door is installed: unobstructed air openings ar
Resumo do conteúdo contido na página número 16
Important Vertical Venting Exhaust back pressure measured by a When vertical dryer venting is used, the length of the ductwork ! manometer/magnehelic in the exhaust duct must from the dryer to the outside exhaust outlet, must not exceed be no less than 0 and must not exceed 0.6 in WC (1.48 12 feet (3.66 meters). The minimum diameter of this ductwork mb). must be at least 4-inches (10.16 cm) for T20, 6-inches (15.24 cm) for T30, and 8-inches (20.32 cm) for T50 and T75. Note Including tumbler/dry
Resumo do conteúdo contido na página número 17
Important Electrical Information_________________ No more than 4 dryers should be connected to 1 ! Electrical Requirements main common duct. All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical The illustration below shows the minimum cross-sectional installation is adequate and conforms to local, state, and area for multiple dryer round or square venting. These figures national regulations or codes of the country of or
Resumo do conteúdo contido na página número 18
Warning (Gas Models Only) Steam Models Only Dryers built for use with a voltage between 200 ! ELECTRICAL SERVICE SPECIFICATIONS and 240 must verify the input voltage during IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify installation. If the nominal voltage is outside of the exact voltage. medium tolerances shown on the diagram below, adjust NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/d
Resumo do conteúdo contido na página número 19
Electric Models Only Grounding All electrically heated dryers must be connected to the electric A ground (earth) connection must be provided and installed service shown on the dryer’s data label. The connecting in accordance with local, state, and national regulations or wires must be properly sized to handle the rated current. codes of the country of origin. In the absence of these codes, grounding must conform to applicable requirements of the ELECTRICAL SERVICE SPECIFICATIONS National Elect
Resumo do conteúdo contido na página número 20
Caution Gas and Steam Models Only The dryer must be grounded. A ground lug has 120-240V Application with Neutral ! been provided for this purpose. Input connection wiring must be sized properly to handle the dryer’s current draw. This information is printed on the dryer’s data label. Electric Models Only Single-Phase (1ø) Wiring Connections/Hookup Two Element Configuration 200-240V Application without Neutral Three Element Configuration Caution The dryer must be grounded. A ground lug has ! b