Resumo do conteúdo contido na página número 1
SpotArm™ Type Blood Pressure Monitor
Model i-Q132
• Instruction Manual EN
FR
• Mode d’emploi
• Gebrauchsanweisung DE
IT
• Manuale di istruzioni
• Manual de instrucciones ES
NL
• Gebruiksaanwijzing
•
RU
AR
IM-HEM-1010-E-04-05/2012
1664040-3E
Resumo do conteúdo contido na página número 2
Contents Before using the unit Introduction .................................................................................3 Important Safety Information .....................................................4 1. Overview ................................................................................7 2. Preparation ..........................................................................10 2.1 Installing/Replacing the Batteries ...............................................10 2.2 Connecti
Resumo do conteúdo contido na página número 3
Before using the unit Introduction Introduction Thank you for purchasing the OMRON i-Q132 Intellisense SpotArm™ Type Upper Arm Blood Pressure Monitor. The OMRON i-Q132 Intellisense is a fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need for pressure pre-setting or re- inflation the device uses its advanced “Intellisense” technology. The adj
Resumo do conteúdo contido na página número 4
Important Safety Information Important Safety Information Consult your doctor during pregnancy, arrhythmia and arteriosclerosis. Please read this section carefully before using the unit. Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) • Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous. • People with severe blood flow problems, or blood disorders, should con
Resumo do conteúdo contido na página número 5
Important Safety Information • Do not inflate the arm cuff over 299 mmHg. • If the cuff does not stop inflating, or some other abnormality occurs, press the Emergency Deflation Switch immediately to prevent from internal bleeding or damage to peripheral nerves. • To inflate the cuff manually, refer to Chapter 3.4. If the cuff is over inflated, it can cause internal bleeding. • Be sure to remove watches and other jewelry (rings, bracelets) etc. that could damage the cuff lining during appli
Resumo do conteúdo contido na página número 6
Important Safety Information General Precautions • Do not apply strong shocks and vibrations to or drop the unit. • Do not take measurements after bathing, drinking alcohol, smoking, exercising or eating. • Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section. • Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device and any used accessories or optional parts. • Wh
Resumo do conteúdo contido na página número 7
1. Overview 1. Overview Main Unit A B C D E F G When the arm cuff is open Rear view H I K L DC6V EN J A. Arm cuff release button I. Elbow rest Press this to open as shown above. J. Arm cuff B. Cuff lining K. AC adapter jack C. MEMORY button L. Emergency deflation switch D. User ID selection button Press this to stop measurement in an emergency. E. Weekly average (Morning / Evening ) button F. START/STOP button G. O/I button (Power switch) H. Handle 7
Resumo do conteúdo contido na página número 8
1. Overview Display Z M AA AB N AC AD O AE P Q R S T U V W X Y M. Systolic blood pressure AA. Morning hypertension symbol Indicates blood pressure out of N. Diastolic blood pressure * recommended range . O. Pulse display AB. Morning average symbol P. Deflation symbol Displayed when viewing morning Q. Date/Time display averages using the memory function. R. Week display AC. Evening average symbol Displayed when viewing evening S. Battery low symbol averages using the memory function. T. Postur
Resumo do conteúdo contido na página número 9
1. Overview Package Contents AG AF AF. Four “AA” alkaline (LR6) • Instruction manual batteries • Quick guide • Guarantee card AG. AC adapter • Blood pressure pass EN 9
Resumo do conteúdo contido na página número 10
2. Preparation 2. Preparation 2.1 Installing/Replacing the Batteries To set the date and time, first insert the batteries, then attach the AC adapter. • Please insert the batteries even if you will be using the AC adapter. The batteries are required to store the date and time setting. If the unit is used without the batteries inserted, the clock will stop when the AC adapter is disconnected. However, the measurement values remain in the memory. • If you use the AC adapter to power the unit,
Resumo do conteúdo contido na página número 11
2. Preparation 3. Install or replace four “AA” size batteries so that the + (positive) and - (negative) polarities match the polarities indicated in the battery compartment. 4. Put the battery cover back in place. Slide the battery cover, until it clicks into place. EN 11
Resumo do conteúdo contido na página número 12
2. Preparation Battery Life & Replacement If the battery low symbol ( ) appears on the display, replace all four batteries at the same time. - When the battery low symbol ( ) starts to blink, you will still be able to use the unit for a short while. You should replace the batteries with new ones ahead of time. - When the symbol ( ) remains lit, the batteries are exhausted. You should replace the batteries with new ones at once. Turn the unit off before replacing the batteries. • Remove the
Resumo do conteúdo contido na página número 13
2. Preparation 2.2 Connecting the AC Adapter Note: Use only the AC adapter designed for this unit. 1. Insert the plug of the AC adapter into the AC adapter jack on the back of the unit. 2. Insert the power plug of the AC adapter into a power outlet. Power plug 2 1 AC adapter AC adapter jack AC adapter plug EN 13 DC6V
Resumo do conteúdo contido na página número 14
2. Preparation 2.3 Setting the Date and Time Your blood pressure monitor automatically stores up to 84 individual measurement values with the date and time for each user. To make use of the memory and average values functions: • Set the unit to the correct date and time before taking a measurement for the first time. • If the batteries have been removed for more than 30 seconds, the Date/Time setting will need to be reset. Set the year, month, day, hours and minutes for the current date and
Resumo do conteúdo contido na página número 15
2. Preparation 2. Press the weekly average buttons to adjust the year setting. • Press the Evening average button once to increase the setting by one year. • Press the Morning average button once to decrease the setting by one year. • Hold the buttons down to increase (decrease) the digits rapidly. Note: The range for the year setting is 2007 to 2030. If the year reaches 2030, it will return to 2007. 3. Press the MEMORY button to confirm the setting when the desired number appears o
Resumo do conteúdo contido na página número 16
2. Preparation 5. Press the MEMORY button to confirm the setting when the desired number appears on the display. The month is set and the day Example: when October has been set as digits flash on the display. the month. 6. Press the weekly average buttons to adjust the day setting. • Press the Evening average button once to increase the setting by one day. Press the Morning average button once to decrease the setting by one day. • Hold the buttons down to increase (decrease) the digits r
Resumo do conteúdo contido na página número 17
2. Preparation 8. Set the hour and minutes in the same way as the date settings. Press the weekly average buttons to adjust the digits for the hour and minutes, then press the MEMORY button to confirm the setting. When the date and time settings have been set, the display changes to that shown to the above. 9. Press the O/I button to turn the power off. Note: You can also start taking readings immediately, rather than turn the unit off. EN 17
Resumo do conteúdo contido na página número 18
2. Preparation Adjusting the Date and Time Setting Note: If you need to change the date and time for some reason, or if the date and time has been reset after replacing the batteries, adjust the date and time between 10:00 and 18:59. This will avoid problems with morning and evening weekly averages stored in the memory. 1. Press the O/I button to turn the power off. 2. Turn the unit on then press and hold the MEMORY button for three seconds or longer when the standby display (shown right
Resumo do conteúdo contido na página número 19
Operating instructions 3. Using the Unit 3. Using the Unit 3.1 How to Sit Correctly When Taking a Measurement Correct posture during measurement is necessary to get accurate results. Notes: • Measurements should be taken in a quiet place and you should be in a relaxed, seated position. Make sure that the room is not too hot or too cold. • Avoid eating, drinking alcohol, smoking, or exercising for at least 30 minutes before taking a measurement. • Do not move or talk during measurement. Remov
Resumo do conteúdo contido na página número 20
3. Using the Unit Note: You can take a measurement on either your left or right arm. The blood pressure can differ between the right arm and the left arm and therefore also the measured blood pressure values can be different. Omron recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your physician which arm to use for your measurement. If you are leaning forwards, this can put pressure Incorrect Posture on your