Resumo do conteúdo contido na página número 1
INSTALLATION
INSTRUCTIONS
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
DIRECT VENT
A French manual is available upon request. Order P/N 700,029CF
SSDV-35/40 SERIES
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 700,029CF.
DIRECT VENT GAS FIREPLACE HEATERS
This appliance may be installed in an aftermarket
P/N 700,029M REV. E 11/2006
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local code
Resumo do conteúdo contido na página número 2
PACKAGING This appliance is only for use with the type TABLE OF CONTENTS of gas indicated on the rating plate. This ap- Packaging .........................................Page 2 pliance is not convertible for use with other The assembled vented gas fi replace heater is gases, unless a certifi ed kit is used. Introduction ......................................Page 2 packaged with: 1 - One log set located in fi rebox area. General Information ..........................Page 2 Cet appareil doit ê
Resumo do conteúdo contido na página número 3
O T I O O L O I P L I T P O O N IGNITER it OFF ON CONTROL TPTH TP TH L O L I P F LO F Input (BTU) Manually-Modulated Gas Manifold Gas Supply Pressure Valves (millivolt models) (electronic models) SIT Millivolt Gas Valve NATURAL GAS Fuel # Max. Manifold Pressure HI/LO Variable Inlet Pressure Tap Flame Height Models Input Rate (BTU / HR) Natural Gas (Hi) 3.5" WC (.87 kPa) Adjustment Manifold Pressure Tap 23,000 high Propane (Hi) 10.0" WC (2.49 kPa) SSDV-3530CNM 17,500 low Table 6 29,000 high S
Resumo do conteúdo contido na página número 4
Note: The following requirements reference various Massachusetts Inspection and national codes not contained in this document. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed Requirements for the Commonwealth of Massachusetts in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. For all side wall horizontal
Resumo do conteúdo contido na página número 5
SAFETY & WARNIING INFORMATION WARNING WARNING WARNING Children and adults should be Carbon monoxide poisoning: alerted to the hazards of high early signs of carbon monoxide If the information in this surface temperatures. Use poisoning are similar to the fl u manual is not follwed caution around the appliance with headaches, dizziness and/or exactly, a fi re or explosion to avoid burns or clothing igni- nausea. If you have these signs, may result causing prop- tion. You
Resumo do conteúdo contido na página número 6
REAR VENT APPLICATION COLD CLIMATE INSULATION For cold climate installations, seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under fl oor on which the appliance rests, if fl oor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fi berglass insulation. If the fi replace is being installed on a cement sl
Resumo do conteúdo contido na página número 7
Horizontal Vent Termination Clearances MANUFACTURED HOME VENT TERMINATION CLEARANCES REQUIREMENTS The horizontal vent termination must have These instructions should be used as a guide- a minimum of 3" (76 mm) clearance to any line and do not supersede local codes in any This appliance may be installed in an after- overhead combustible projection of 2 1/2" (64 way. Install vent according to local codes, market permanently located, manufactured mm) or less. See Figure 6. For projections
Resumo do conteúdo contido na página número 8
V EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal G Termination 18” V Ventilated Soffi t A Inside Corner = 9" in U.S. A = 12" in Canada DETAIL D H 3 ft. B B D E X C A A V Fixed Operable V L V Closed Window 3 ft. Window V F C B J V M C C B B V I A = Vent Terminal X = Air Supply Inlet V = Area where Terminal is NOT permitted Minimum Clearances Canadian Installation * US Install
Resumo do conteúdo contido na página número 9
MINIMUM CLEARANCES TO COMBUSTIBLES Appliance and Vent Clearances Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is The appliance is approved with zero clearance to used, do not block the lower control compartment door. Any hearth extension used is for appearance combustible materials on all sides (as detailed only and does not have to conform to standard hearth extension installation requirements. in Table 8), with the following exception: Whe
Resumo do conteúdo contido na página número 10
DETAILED INSTALLATION STEPS Step 4. (Page 25) Field Wiring a. Millivolt Appliances – Install the operating The appliance is shipped with all gas controls control switch (not factory provided) and and components installed and pre-wired. Re- bring in electrical service line for forced air move the shipping carton, exposing the front circulating blower (optional equipment). Unit Nailing Flange glass door. Remove the top and bottom louvered Side b. Electronic Appliances – Field wire and inst
Resumo do conteúdo contido na página número 11
FIREPLACE SPECIFICATIONS **Framing With Square Horizontal Termination SV4.5HT-2 Framing Dimensions - Inches (millimeters) **Framing should be constructed VENT FRAMING - Models A B C D E of 2 x 4 or larger lumber. TOP VENT WITH ONE SSDVT-3530 35-1/4 (895) 35-1/4 (895) N/A 39-3/4 (1010) 16" 90 ELBOW 10-1/2 (267) SSDVR-3530 35-1/4 (895) 35-1/4 (895) 21-11/16 (551) N/A 16" SSDVT-4035 40-1/4 (1022) 40-1/4 (1022) N/A 44-3/4 (1137) 16" VENT FRAMING - REAR VENT WITH SSDVR-4035 40-1/4 (1022) 40-1/4 (10
Resumo do conteúdo contido na página número 12
FIREPLACE FRAMING SPECIFICATIONS Note- SSDV-3530 Models - • Venting requirements for rear vent applications in corner installations, the horizontal vent length “a” to “b,” must not exceed 28 inches (711). • Dimensions D and F occur when one 45 degree elbow is connected directly to the appliance collar. b F Inches 7 1/4 (184) (millimeters) Model No. AB C D E F i8 n.32 5 1/58 7 1/46 0 5/14 9 3/128 8 3/ 6 1/ C SSDV-3530 E m2 m81 912 4617 03 40 8 76 3 15 D i8 n.46 0 1/62 1 3/146 3 1/316 9 3/138
Resumo do conteúdo contido na página número 13
Step 3. INSTALL THE VENT SYSTEM Installation of Vent Restrictor VENT RESTRICTOR INSTALLATION A vent restrictor may be needed with this appliance, (REAR VENT) General Information install vent restrictor (provided) in the appliance top A vent restrictor may be needed when horzon- These instructions should be used as a guide- fl ue outlet as shown in Figure 16 (SSDVT-3530 tally terminating the vent system from the rear line and do not supersede local codes in any and SSDVT-4035) or rear fl ue o
Resumo do conteúdo contido na página número 14
VERTICAL TERMINATION SYSTEMS (ROOF) VENT SECTION LENGTH CHART VENT SECTION LENGTH CHART Nominal 612 24 36 48 T Nominal Section 612 24 36 48 T Figure 21 (Page 15), and Figures 26 to O Section Length Length (inches) O T 30 (Pages 17 and 18) and their associated (inches) T Net Section 4 ½ 10 ½ 22 ½ 34 ½ 46 ½ A A Vertical Vent Tables illustrate the various verti- Length (inches) L Net Section 4 ½ 10 ½ 22 ½ 34 ½ 46 L cal venting confi gurations that are possible for Length (inches) ½ Height of
Resumo do conteúdo contido na página número 15
Vertical (Offset) Installation To add another vent component to a length of B. Attach vent components to appliance vent run, align the dimpled end over the inclined - Secure Vent SV4.5 direct vent system compo- Analyze the vent routing and determine the channel end of the previously installed section, nents are unitized concentric pipe components quantities of vent sections and number of elbows adjusting the radial alignment until the four lock- featuring positive twist lock connections (
Resumo do conteúdo contido na página número 16
One method of support is by utilizing fi eld pro- K. Install the vertical termination - The fi nal step involves installation of the SV4.5CGV-1 vided support straps (conventional plumber's Vertical Termination. Extend the vent sections tape). Secure the plumber's tape to the framing to the height as shown in the "Vertical vent ter- members with nails or screws. Loop the tape around the vent, securing the ends of the tape C mination section" on Page 7. The SV4.5CGV-1 to the framing. If de
Resumo do conteúdo contido na página número 17
VERTICAL VENT FIGURES/TABLES Table A Note: Secure Vent (rigid vent pipe) is shown When using Secure Flex, use Firestop / in the Figures; Secure Flex (fl exible vent pipe) V Minimum H Maximum Spacer SF4.5VF. may also be used. feet (meter) feet (meter) 2 (0.610) 1 (0.305) WARNING 4 (1.219) 2 (0.610) Under no circumstances, may sepa- 6 (1.829) 3 (0.914) rate sections of concentric fl exible 8 (2.438) 4 (1.219) vent pipe be joined together. V + H = 40 feet (12.2 meters) Max. Notes:
Resumo do conteúdo contido na página número 18
VERTICAL VENT FIGURES/TABLES (CONTINUED) Table C H1 H+H Maximum H Maximum V Minimum 1 feet (meter) feet (meter) feet (meter) Ceiling 5 (1.524) 2 (0.610) 1 (0.305) Firestop / Spacer 10 (3.048) 4 (1.219) 2 (0.610) (SV4.5VF) 15 (4.572) 6 (1.829) 3 (0.914) 20 (6.096) 8 (2.438) 4 (1.219) Wall Firestop/ Spacer (SV4.5HF) V + V + H + H = 40 feet (12.2 m) Max 1 1 V1 H = 8 feet (2.438 meters) Max. Ceiling Firestop / Spacer H + H = 20 feet (6.096 meters) Max. 1 (SV4.5VF) When using Secure
Resumo do conteúdo contido na página número 19
Support Brackets Building Support Horizontal / Inclined Run Framing SV4.5HT-2 Termination SV4.5E90 Shown Elbow SV4.5L6/12/24/36/48 Vent Sections Exterior Ceiling Firestop / Spacer Wall Vertical SV4.5VF Support Bracket Spacing Rise Every 5 ft (1.52 m) When Using Secure Flex, Use Firestop / Spacer SF4.5VF SV4.5HT-2 Termination See Figure 18 on Page 14 or Figure 21 on Shown Page 15 for vertical vent section support. Fireplace Figure 31 - TYPICAL HORIZONTAL VENT INSTALLATION B. Frame exterior
Resumo do conteúdo contido na página número 20
J. Assemble vent run to exterior wall - If not To help minimize water infiltration it is previously measured, locate the center of the recommended that the Firestop/Spacer vent at the exterior wall. Prepare an opening as (SV4.5HF) be installed on the exterior side of the wall. described in Step B. Assemble the vent system SV4.5 HT-2 to point where the terminus of the last section is Termination 7" located relative to the exterior surface to which (178) 12¹⁄₈" 10¹⁄₂" the termination is to b