Resumo do conteúdo contido na página número 1
KOBE Brand Range Hood
Model No. RA9236S
RA-092 SERIES – 12” HEIGHT
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
Resumo do conteúdo contido na página número 2
- READ AND SAVE THESE INSTRUCTIONS - CONTENTS Important Safety Instructions………………………………………………………………. 1 Components of Packages………………………………………………………………….. 3 Installation…………………………………………………………………………………… 4 Operating Instructions…………………………………...…………………………………. 9 Maintenance…………………………………………………………………………………. 10 Specifications…………………………………………………….……..…………………… 12 Measurements & Diagrams…………………………………………………………...…… 13 Parts List…………………………………………………………………..…………………. 14 Circuit
Resumo do conteúdo contido na página número 3
IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3)
Resumo do conteúdo contido na página número 4
What to Do In The Event Of a Range Top Grease Fire - SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. - NEVER PICK UP A BURNING PAN – You may get burned. - DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. - Use an extinguisher ONLY if:
Resumo do conteúdo contido na página número 5
COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) Range Hood Box {A} KOBE Range Hood with Two-Piece Duct Cover {B} Warranty Registration Card {C} Instructions Manual {D} Duct Cover-Mounting Bracket {E} Hood-Mounting Bracket {F} Oil Containers (Round) {G} Oil Containers (Oval) {H} Screws Package {A} {D} {E}
Resumo do conteúdo contido na página número 6
INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate the length of the installation, please refer to Table 1. (All calculation is measure in inches.) TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”) D = Height of Hood E = Height of Duct
Resumo do conteúdo contido na página número 7
- Temporarily wire the hood to test for proper operation before installing. - Peel protective film off the duct cover and the hood (if any). - Loosen hood-mounting brackets at the back of the hood, adjust brackets and tighten screws as shown in Figure 3. - If necessary to remove the rubber stand on the back of the hood, unscrew and discard. Refer to Figure 4. Figure 1 Figu
Resumo do conteúdo contido na página número 8
Mounting Screws Figure 5 Ductwork Installation 5. Use 6” round aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 6. Figure 6 Wiring to Power Supply SAFETY W ARNING RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD M
Resumo do conteúdo contido na página número 9
9. Using reference E from Table 1 and measurements on page 13, mark the leveling point for duct cover-mounting bracket. 10. Secure the duct cover-mounting bracket to the wall with two screws (not provided). Refer to Figure 7. Make sure all screws are tightened. NOTE: Inner duct cover will cover the duct cover-mounting bracket. 11. Slide up inner duct cover up 2 inches before sliding entire duct cover onto the hood. Refer to Figure 8.
Resumo do conteúdo contido na página número 10
Figure 10 Figure 11 Final Assembly 16. Turn power ON in control panel. Check all lights and fan operation. 17. Make sure to leave this manual for the homeowner. 8
Resumo do conteúdo contido na página número 11
OPERATING INSTRUCTIONS This KOBE hood is equipped with three-switch control, two powerful centrifugal turbine impellers with safety screens, two bright 12-volt 20-watt halogen lights, and four oil containers. The three control switches are Light Control, Speed Control, and the Power Control (On/Off). Refer to Figure 12. Figure 12 Light Control
Resumo do conteúdo contido na página número 12
MAINTENANCE CAUTION: NEVER PUT YOUR HAND INTO THE AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For the optimal level of operation, clean the range hood surface, safety screens, and oil containers regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1) Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2) If hood looks splotchy (stainless steel hood
Resumo do conteúdo contido na página número 13
To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL. 1) Make sure all control switches are off, and range hood is unplugged. 2) Use a flat head screwdriver to pop out the protective covering as shown in Figure 15. 3) Gently pull out the defective light bulb and discard. Light bulbs should be 12V 20W maximum. Refer to Figure 16. Push bulb securely into light socket. 4) Replace protective cover. 5) Plug in range hood.
Resumo do conteúdo contido na página número 14
SPECIFICATIONS MODEL / SIZE RA9236S / 36” COLOR # 430 Commercial Grade Stainless Steel VOLTAGE 120V 60Hz NUMBER OF MOTORS 2 DESIGN 18-Gauge Seamless FAN TYPE Twin Turbine Impeller EXHAUST 6” Round CONTROLS Two Speed (Low & High) HALOGEN LIGHTS 12V 20W x 2 HOOD DIMENSION (W x D x H) (RA9236S) 35-1/4” x 20-1/2” x 12-1/4” DUCT COVER DIMENSION (RA9236DC) 10-5/8” x 7-7/8” x (14-1/8”~27-1/8”) (W x D x H) OPTIONAL ACCESSORIES 1) One-Piece Extension Duct Cover (W x D x H)
Resumo do conteúdo contido na página número 15
MEASUREMENT & DIAGRAM ***All inch measurements are converted from millimeters. Inch measurements are estimated. ***All measurements in ( ) are millimeters. ***Hood-Mounting Bracket ***Duct Cover-Mounting Bracket 13
Resumo do conteúdo contido na página número 16
PARTS LIST MODEL NO.: RA9236S NO. DESCRIPTION MODEL /SIZE PART NO. 1 6” Round Plastic Exhaust C1-0506-0101 2 Capacitor C1-0401-0120-01A 3 Transformer (Motor) C1-0402-0120-40 4 Screw (4 x 6 mm) C1-0708-0001 5 Screw (4 x 6 mm) C1-0708-0001 6 Power Cord C1-0406-0120 7 Round Head Screw (TS 4 x 18 mm) C1-0708-0004 8 Plastic Plate C1-0507-0101 9 Hood Casing 10-00920-A 10 Transformer Support C1-0201-0092 11 Halogen Light (12V 20W Max.) C1-0403-0101
Resumo do conteúdo contido na página número 17
MODEL NO.: RA9236S 15
Resumo do conteúdo contido na página número 18
CIRCUIT DIAGRAM MODEL NO.: RA9236S KEY CODE B = Blue BK = Black BR = Brown W = White = Green GR Y = Yellow G = Grey L = Left R = Right 16
Resumo do conteúdo contido na página número 19
DISCLAIMER 1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM. Upon acceptance of items, owner assumes responsibility for its safe arrival. Damages should be reported to carrier and a claim filed. Failure to do this could result in the carrier refusing to honor your claim. The carrier will furnish you with necessar
Resumo do conteúdo contido na página número 20
WARRANTY WARRANTY CERTIFICATE KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement at its option and subject to the terms and conditions stated below, of any component part, which its examination shall disclose to be so defective. TWO-YEAR WARRANTY SERVICE PERIOD