Resumo do conteúdo contido na página número 1
WINDOW TYPE ROOM AIR CONDITIONER
HW-09LN03
HW-12LN03
No.0010515690
Resumo do conteúdo contido na página número 2
Contents 1 Parts and Functions 2-3 Operation Guide 4-9 Maintenance 10-13 Installation Instruction 14-15 Wiring Diagram 16 1
Resumo do conteúdo contido na página número 3
Front panel Air inlet (indoor side) Machine body Air outlet (indoor side) Air inlet (outdoor side) Display panel Power plug Air filter (inside) 1 2 3 4 5 FAN SPEED 6 7 8 MODE FAN,COOL,DEHUM. FAN SPEED :HIGH or LOW. SWING ENERGY SAVER Used to activate ENERGY SAVER option,reduce energy consumption and noise. POWER 2
Resumo do conteúdo contido na página número 4
POWER 1 MODE FAN SPEED 2 FAN,COOL,DEHUM. 3 FAN SPEED TIMER button Used for TIMER start or stop . 4 TEMP. or TIME set 5 Used to set TIME or TEMP . setting . E-S 6 ENERGY SAVER SWING 7 E-S 3
Resumo do conteúdo contido na página número 5
COOL 1.Start Press POWER button 2. Select operation mode Press MODE button. For each press, operation mode FAN COOL DEHUM changes as follows: Then select COOL operation. When the COOL display lights bright, the unit will be working under the cooling function. FAN SPEED 3. Select temp. setting 4. Fan speed selection If you choose the FAN SPEED mode you can run the fan in one of the 2 speeds: HIGH or LOW. Select desired setting. Change air flow direction if necessary. 5. Stop Press PO
Resumo do conteúdo contido na página número 6
E-S DEHUMID mode 1. Start Press POWER button. 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: FAN COOL DEHUM Then select DEHUMID operation. When the DEHUM display lights bright, The unit will be 5 working under the dehumidify function. If you need to only remove the moisture press the FAN SPEED Dehnmid button. Change air flow direction if necessary. 4 3. Select temp. setting 4. Fan speed selection If you choose the FAN SPEED mode you can r
Resumo do conteúdo contido na página número 7
FAN operation 1. Start Press POWER button. 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: FAN COOL DEHUM 4 Then select FAN operation. FAN SPEED When the FAN display lights bright ,the unit will be working under the fan operation. In some days you may want to run the FAN function. Press the FAN button. 3. Fan speed selection Here the fan runs only at HIGH or LOW speed. Change air flow if necessary. 4. Stop Press POWER button again. E-S FA
Resumo do conteúdo contido na página número 8
ENERGY SAVER operation 1. Start Press POWER button. 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: FAN COOL DEHUM 4 Then select COOL operation. When the COOL display lights bright,the unit will FAN SPEED be working under the COOL function. Saving energy function only can be used when A/C working on cooling condition. ENERGY SAVER selection When this function is selected, the fan will shut off three minutes after the compressor cycles o
Resumo do conteúdo contido na página número 9
On Off 24 On Off cool On 24 Press "On"of remote controller or "TIMER" of control panel, Off panel, Press "Off"of remote controller or "TIMER"of control TIMER ON mode restarted FAN SPEED FAN SPEED E-S 8
Resumo do conteúdo contido na página número 10
Power failure resume(please set and apply as necessary) If sudden power failure occurs, the unit will resume original operation when power is supplied again. Note: When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press POWER to turn off the unit when power resumes. Operation Adjust
Resumo do conteúdo contido na página número 11
pulling Pull Pull ush " CLOSE"position, the vent door opens to allow air, smoke or odors to be expelled from the room; " OPEN"position, the vent door is closed and the air inside the room is circulated and conditioned. OPEN CLOSE 10
Resumo do conteúdo contido na página número 12
11
Resumo do conteúdo contido na página número 13
Disposal of the condensed water Generally there are two methods available on disposal of the condensed water: 1. Block the bottom plate hole of the conditioner with rubber lid, install outlet pipe fitting on the back hole and let the condensing water flow from the back hole of the conditioner. (See Fig.1 ) In this method, the accumulated condensed water in the bottom plate is hit by the fan onto the heat exchanger, and evaporated and blown out from the machine. It can cool the heat exchanger
Resumo do conteúdo contido na página número 14
13
Resumo do conteúdo contido na página número 15
Outlet Battery Remote Screw Name Manual Sealed gasket Rubber lid controller (R-03 dry battery) pipe fitting Figure 2 1 1 1 1 1 3 Quantity 14
Resumo do conteúdo contido na página número 16
MODEL HW-09LN03 366mm 481mm 392mm 610mm HW-12LN03 outlet pipe fitting outlet pipe fitting outlet pipe fitting 15
Resumo do conteúdo contido na página número 17
PROTECTOR Wiring Diagram 0010511621 WIRING DIAGRAM COMPRESSOR FAN MOTOR M S RECEIVING HEAD LOUVER R C BR MOTOR B M CAPACITOR M L H BR M BL B BL OR B R BL RBL CN13 CN12 CN8 CN9 CN11 CN10 CN14 CN3 3 4 FUSE CN2 TEMP.SENSOR COMP.RELAY 250V/3.15A BR Y/G BL POWER SUPPLY R:RED OR:ORANGE NOTE:1.Because of different compressor,the dotted part may not be used. B:BLACK BR:BROWN 2.There are no dotted lines on some types. BL:BLUE (marked with @) Y/G:YELLOW/GREEN Dimensions(indoor Power input/ Current/Rate
Resumo do conteúdo contido na página número 18
- - With 3 years warranty on all air- conditioner compressors, you have peace of mind from the date of purchase - NATIONWIDE SALES AND SERVICES - - MINNA,ILORIN,OSHOGBO,LOKOJA, sales office 7 2719790
Resumo do conteúdo contido na página número 19
Resumo do conteúdo contido na página número 20