Resumo do conteúdo contido na página número 1
SPLIT AIR CONDITIONER
OPERATION
MANUAL
AS102AMARA
AU102ACARA
(HSU-10HA03(DB))
AS102ALARA
AU102ACARA
(HSU-10H03(DB))
AS122AYARA
AU122ACARA
(HSU-12HA03(DB))
AS122AVARA
AU122ACARA
(HSU-12H03(DB))
Digital DC Variable Frequency
Healthy Split Air Conditioner
Please read this manual carefully before use.
Please keep this manual carefully and safely.
No.0010540438
I
Resumo do conteúdo contido na página número 2
Contents Cautions........................................................................................................1-2 Name of Parts...............................................................................................3-4 Operation Hints............................................................................................5-6 Operation.....................................................................................................7-13 Notes for Safety.....................
Resumo do conteúdo contido na página número 3
Cautions All these valuable materials may be taken to Disposal of the old air conditioner a waste collecting center and used again after adequate recycling. Before disposing an old air conditioner that goes out of use. please make sure it's Consult your local authorities for the name inoperative and safe. Unplug the air and address of the waste materials conditioner in order to avoid the risk of child collecting centers and waste paper diposal entrapment. services nearest to your house. Safety I
Resumo do conteúdo contido na página número 4
Installation Check and Trial Operation Cautions Please operate the air conditioner in accordance with this Operation Manual Check items for the Trial Operation(Tick in ) For the purpose of safety, the air Specifications Is the connector leaked? conditioner must be properly grounded in The refrigerating circuit is leak-proof. How is the connector insulated? accordance with specifications. Is the electric connection between the indoor and outdoor units firmly inserted into the The machine is adapt
Resumo do conteúdo contido na página número 5
Installation Name of Parts Indoor Unit: Wiring for Indoor and Outdoor Units 1. Inlet Grill 1. Wiring Method for Ring Terminal 2. Anion Generator (inside) The wiring method is as the drawing below for the ring terminal: 3. Air Filter Remove the connection screw and put the screw through the ring on 4. Swing louver the connection wire terminal, then connect it to the terminal blocks, It can be adjusted to upward or downward with the remote controller only (Do not adjust it manually) then screw it
Resumo do conteúdo contido na página número 6
Name of Parts Installation Remote Controller: Piping Connection for Outdoor Unit Introduction to Display and Function: Connect the Piping and Inlet and Outlet Liquid Tubes 1. Mode Gas Drainage Method: Mode selected is displayed Drain the air in the indoor unit and the pipes as per the drawing: 2. Air Volume (1) Remove the valve cap on the two-way valve of the indoor unit with a spanner. Indicating the air speed, when automatic is set, the air speed changes according to the temperature (2) Unscre
Resumo do conteúdo contido na página número 7
Installation Operation Hints Air Conditioner Operation: When the ambient humidity is too high, 4.Piping Connection for Indoor Unit: the anion effect would be reduced, so during Insert the auxiliary hoses(liquid hose and gas hose)and the unit connection wires through the wall the cooling and dehumidifying, water hole from outdoor side,and connect the pipes and wires as per the method of piping connection, or would drop from the outlet mouth insert the auxiliary hoses(liquid hose and gas hose) and
Resumo do conteúdo contido na página número 8
Operation Hints Installation Installation of Indoor Unit Wait a moment Hanging Wire Drop Wire Here The indoor unit shall be installed as per the indoor unit Cold Air Prevention Mounting Plate installation drawing: When heating is started, the fan in the indoor unit will not be started immediately to prevent cold air being blew 3 out. Wire Holes for Fixing Dropping Weight A145mm Find out the Level Position Defrost A=185mm During the heating, when the heat exchanger in the 60mm outdoor unit is fro
Resumo do conteúdo contido na página número 9
Installation Operation Localize the Installation: , Remote Controller s Operation Indoor Unit When in use, point the signal sending head directly to the receiver window on the indoor unit. Install the indoor unit where the weight of the unit can be supported. The distance between the signal sending head and the receiver window should be within 7 m Install the indoor unit where the head source and steam source are not close and the unit inlet and without any obstacle as well. outlet are not block
Resumo do conteúdo contido na página número 10
Operation Installation 1. Installation Localization 2. Indoor Unit Mounting Plate Localization 3. Drill through Wall Small Hints: Remove the batteries in case the unit won't be in use for a long period. The remote controller will be self-checked after loading the new batteries by displaying all the symbols and resume working very soon. 4. Connect Indoor Unit 5. Install Indoor Unit 6. Install Outdoor Unit Health Operation 1. After turning on the air conditioner, set to the desired mode: The remot
Resumo do conteúdo contido na página número 11
Installation Operation To enable the air conditioner to work well, please install it as required by this manual. Cooling / Dehumidifying/Heating Operation When moving the air conditioner, please don't scratch the shell. Recommended Modes: The max. length of the connection pipe is 15 meters, and the max. height difference between the Cooling mode for summer; indoor unit and outdoor unit is 7 meters for AS122 AVARA/AU122 ACARA(HSU-12H03(DB)) Heating mode for winter; AS122AYARA/AU122ACARA(HSU-12HA0
Resumo do conteúdo contido na página número 12
Operation Installation Installation Tools 1. Screw Driver (flat head, wabbler, triangle) 5. Adjustment of Air Flow Direction 2. Steel Saw After selecting the mode, swing louver will automatically be opened to the position as the drawing 3. 60mm Drill indicates: 4. Inner Hexagon Spanner 5. Shifting Spanner 6. Spanner (14,17,19, 27 mm) Horizontal Cooling Mode 7. Pipe Cutter o Approx.10 Heating Mode 8. Pipe Expander o Approx.60 9. Knives Up and Down Adjustment (with remote controller) 10. Clippers
Resumo do conteúdo contido na página número 13
more than 5 cm More than 10 cm more than 15 cm more than 10 cm more than 10 cm Installation Operation Installation Drawing for Indoor and Outdoor Units Time Set Operation With the time set function, the air conditioner can be turned on and off automatically at your set time. You can let your air conditioner be turned on or off automatically after you wake up in the morning, Mounting Plate before you come back from work in the evening, or after you fall asleep at night. 1. After turning on the ai
Resumo do conteúdo contido na página número 14
Operation Trouble Shooting Super Mode Operation Insufficient Cold Air or Hot Air When you need to cool or heat your room rapidly, you can use this function. Has the mode been selected correctly? Is the dust filter too dirty? (it should be cleaned Set Super Mode Operation : once every two weeks) Press the POWER button each time the display will vary in the following sequence: No Display Stop at . Has the inlet or outlet been blocked? Is the door or window open? At the state of Super Mode Operatio
Resumo do conteúdo contido na página número 15
Hua! Hua! Hua! Trouble Shooting Operation Emergency Operation & Test Operation When your remote controller is lost or cannot be used, the unit can be operated with a Air does not blow or the fan speed cannot be During the dehumidifying operation, when the function of emergency operation. changed during the dehumidifying mode. room temperature is less than 2 higher than The test operation can be applied when the cooling test operation is carried out under the the temperature set, the air conditio
Resumo do conteúdo contido na página número 16
Hua Notes for Safety Trouble Shooting The followings are not malfunction: The power supply plug must have the earth line After electric wiring , the air conditioner shall to ensure that the air conditioner may be be electrified to check for electric leakage. Water flowing sound is heard. When the air conditioner is started, when the grounded effectively through the power supply compressor starts or stops during operation or socket. Non-grounding or incomplete grounding when the air conditioner i
Resumo do conteúdo contido na página número 17
Maintenance Notes for Safety Maintenance after Season of Use Do not spray any paint or insecticide on the air Turn on the machine and let it operate for half a day under the status of sending air in Conditioner. a sunny day so as to make the inside of the air conditioner fully dry. Insecticide Paint Clean the dust filter, the indoor unit, and outdoor unit, then cover it. Never pour water on the indoor unit. Keep the inlet and outlet of the indoor unit unblocked. Maintenance before Season of Use
Resumo do conteúdo contido na página número 18
Maintenance Maintenance Clean the Air Conditioner Installation and Replacement of Air Filter Do not clean it with hot water Do not touch the machine with Turn off Power 1. Open the inlet grill as drawing: wet hands or detergent 2. Remove the dust filter and slightly push the filter upward then pull downward. Open the inlet grill upward Dust Filter 3. Install the air filter by inserting it into left and right frames with the white side upward. Remove the dust filter: Slightly push it upward then