Resumo do conteúdo contido na página número 1
Installation Manual
TLA 700 Series
Logic Analyzer
070-9774-02
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
Resumo do conteúdo contido na página número 2
Copyright Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the Commercial Computer Software – Restricted Rights clause a
Resumo do conteúdo contido na página número 3
TEKTRONIX SERVICE OPTIONS Tektronix offers the following service options. These options are modular, flexible, and easy to order with your instru- ment. Designed to ease installation and start up, to support tracking of calibration to requirements of ISO9000, and to provide for extended repair coverage, these options help fix your long-term maintenance costs and eliminate un- planned expenditures. And these options can be converted from service at Tektronix service depots to service on-site (see
Resumo do conteúdo contido na página número 4
Resumo do conteúdo contido na página número 5
Table of Contents General Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Service Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x Service Offerings . . . . . . . . . . . . . . . . . . . . .
Resumo do conteúdo contido na página número 6
Table of Contents List of Figures Figure 1: Location of ground connections . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2: Installing modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 3: Installing the empty slot panel covers . . . . . . . . . . . . . . . . . . 6 Figure 4: Locations of external connectors . . . . . . . . . . . . . . . . . . . . . . 7 Figure 5: Connecting the logic analyzer probes . . . . . . . . . . . . . . . . . . 9 Figure 6: Line fu
Resumo do conteúdo contido na página número 7
Table of Contents List of Tables Table 1: Mainframe operating requirements . . . . . . . . . . . . . . . . . . . . 3 Table 2: Additional accessory connection information . . . . . . . . . . . . 8 Table 3: Line fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Table 4: Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 5: Software not covered by the TLA 700 Series software setup 41 Table 6: Controller BIOS setu
Resumo do conteúdo contido na página número 8
Table of Contents iv TLA 700 Series Installation Manual
Resumo do conteúdo contido na página número 9
General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. While using this product, you may need to access other parts of the instrument. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system. To Avoid Fire or Use Proper Power
Resumo do conteúdo contido na página número 10
General Safety Summary Symbols and Terms Terms in this Manual. These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an inju
Resumo do conteúdo contido na página número 11
Service Safety Summary Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service procedures. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present. Disconnect Power. To avoid electric shock, disconnect the main power by means of the power cord or, if provided, the power switch. Use Caution
Resumo do conteúdo contido na página número 12
Service Safety viii TLA 700 Series Installation Manual
Resumo do conteúdo contido na página número 13
Preface The TLA 700 Series Installation Manual is intended to help you install your TLA 700 Series Logic Analyzer. Although your TLA 700 Series Logic Analyzer may arrive with all modules installed, you should still follow the steps in this manual to complete the installation process. The manual consists of the following sections: Basic Installation describes the hardware installation process and provides information to start the logic analyzer the very first time. Installing Microprocessor
Resumo do conteúdo contido na página número 14
Preface Related Documentation In addition to this installation manual, the following documentation is available for your TLA 700 Series logic analyzer: The TLA 700 Series Logic Analyzer User Manual provides basic operating information for the TLA 700 Series Logic Analyzer. The online help provides information about the TLA 700 Series user interface. To view the online help, select Help Topics from the Help menu. A series of microprocessor support instruction manuals provide operating and s
Resumo do conteúdo contido na página número 15
Preface Service Offerings Tektronix provides service to cover repair under warranty as well as other services that are designed to meet your specific service needs. Whether providing warranty repair service or any of the other services listed below, Tektronix service technicians are well equipped to service the TLA 700 Series Logic Analyzers. Tektronix technicians train on Tektronix products; they have access to the latest information on improvements to the TLA 700 Series Logic Analyzers as well
Resumo do conteúdo contido na página número 16
Preface Self Service. Tektronix supports repair to the replaceable-part level by providing for circuit board exchange. Use this service to reduce down-time for repair by exchanging circuit boards for remanufactured ones. Tektronix ships updated and tested exchange boards. Each board comes with a 90-day service warranty. For More Information. Contact your local Tektronix service center or sales engineer for more information on any of the Calibration and Repair Services just described. Contacting
Resumo do conteúdo contido na página número 17
Basic Installation This chapter describes all of the steps needed to install the TLA 700 Series Logic Analyzer. It is written from the perspective that you purchased most of the items uninstalled and you intend to install all of the pieces. If you purchased a logic analyzer with modules already installed, you should still review all of the information in this chapter and perform those steps that apply to your specific situation. This chapter deals mainly with hardware installation. The basic ope
Resumo do conteúdo contido na página número 18
Basic Installation Check the Environmental Requirements Read this section before attempting any installation procedures. This section describes site considerations, power requirements, and ground connections for your logic analyzer. Site Considerations: The portable mainframe is designed to operate on a bench or on a cart in the normal position (on the bottom feet). For proper cooling, at least two inches Portable Mainframe (5.1 cm) of clearance is recommended on the rear and sides of the mainfr
Resumo do conteúdo contido na página número 19
Basic Installation Operating Requirements Table 1 lists the operating requirements for the logic analyzers. Refer to the TLA 700 Series Logic Analyzer User Manual for a complete specification list. Table 1: Mainframe operating requirements Requirement TLA 704 Color Portable mainframe TLA 711 Color Benchtop mainframe Source voltage 90–250 V , 45–66 Hz, continuous range 90–250 V , 45–66 Hz, continuous range RMS RMS 100–132 V , 360–440 Hz, continuous range 100–132 V , 360–440 Hz, continuous range
Resumo do conteúdo contido na página número 20
Basic Installation Chassis Ground Figure 1 shows chassis ground connections. Use the chassis ground connections to connect the grounds of one or more instruments to the logic analyzer to ensure Connections a common ground connection between instruments. WARNING. Do not remove the safety ground screw from the benchtop mainframe. The safety ground screw must always be in place to ensure the proper bonding of the power supply to the mainframe. Chassis ground Safety ground (Benchtop mainframe only)