Resumo do conteúdo contido na página número 1
User’s Manual
ICS-100 / ICS-102 / ICS-102S15
RS-232/RS-422/RS-485
over
100Base-FX / 10/100Base-TX
Media Converter
Resumo do conteúdo contido na página número 2
User’s Manual of ICS-10x Trademarks Copyright © PLANET Technology Corp. 2008. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merc
Resumo do conteúdo contido na página número 3
User’s Manual of ICS-10x TABLE OF CONTENTS 1. INTRODUCTION .............................................................................................................1 1.1 PACKAGE CONTENTS .................................................................................................................................. 1 1.2 HOW TO USE THIS MANUAL......................................................................................................................... 1 1.3 PRODUCT DESCR
Resumo do conteúdo contido na página número 4
User’s Manual of ICS-10x 4.5 SERIAL PORT CONFIGURATION .................................................................................................................. 47 5. SOFTWARE VCOM UTILITY .......................................................................................49 5.1 INSTALLING THE VCOM UTILITY ................................................................................................................ 49 5.2 SEARCH THE DEVICE....................................
Resumo do conteúdo contido na página número 5
User’s Manual of ICS-10x 1. INTRODUCTION Thank you for purchasing PLANET Serial over Fast Ethernet Media Converter – ICS-10x series. Terms of “Serial Media Converter” means the products mentioned titled in the cover page of this User’s manual 1.1 Package Contents Open the box of the Serial Media Converter and carefully unpack it. The box should contain the following items: Check the contents of your package for following parts: Serial Media Converter x1 CD-ROM user's manual x1 Quic
Resumo do conteúdo contido na página número 6
User’s Manual of ICS-10x 1.3 Product Description The Web-Smart ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485 communication interface over Fast Ethernet networking. There are RJ-45/SC connectors and single-mode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily, efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET Media Con
Resumo do conteúdo contido na página número 7
User’s Manual of ICS-10x Process Control To monitor, configure and manage the Robot conveyer including other machines in a manufacturing, PLC (Programmable Logical Control) is required. The PLC is used to drive above the manufacturing machines process. The ICS-10x can be set to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast Ethernet intranet to control the PLC, the administrator and workstation. There is no need to be always set
Resumo do conteúdo contido na página número 8
User’s Manual of ICS-10x Surveillance motion control – Pair Connection Mode Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232/RS-485 interfaces distance from surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center. Figure 1-4 Serial Converter for distance extend application 1.5 Product Features Serial Interface One RS-232/422/485 port to one 10/100Base-TX or 100Base-FX Media Converter Cost eff
Resumo do conteúdo contido na página número 9
User’s Manual of ICS-10x Co-work with PLANET MC family Media Chassis ( MC-700/1000R/1500) LED indicators for easy network diagnose Reset Button at the front panel for reset to factory default 1.6 PRODUCT SPECIFICATION Products ICS-100 ICS-102 ICS-102S15 Hardware Specification Interface RS-232 / RS-422 / RS-485 Connector 3-in-1 DB9 Baud rate 110 to 921600bps Character Bits 5,6,7,8 Parity type 1,2 Serial Port Stop Bit None, Even, Odd Flow Control None, RTS/CTS, Xon/Xoff RS
Resumo do conteúdo contido na página número 10
User’s Manual of ICS-10x Dimension (W x D x H) 97 x 70 x 26mm Weight 200g Power Supply External Power Adaptor 5V DC / 2A max. Power Consumption 5.5 Watts (maximum) Mechanical Metal Operating Temperature: 0~50 Degree C Storage Temperature: -10~70 Degree C Environment Humidity: 10%~90% RH (operating) 5%~90% RH (Storage) Emissions FCC Class A, CE Certification Class A IEEE 802.3 10Base-T Standards IEEE 802.3u 100Base-TX / 100Base-FX EIA/TIA RS-232/422/485 Regulatory Approval
Resumo do conteúdo contido na página número 11
User’s Manual of ICS-10x 2. INSTALLATION This section describes the hardware features and installation of the ICS-10X’s components on the desktop or shelf. For easier management and control of the ICS-10x, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Serial Media Converter, please read this chapter completely. 2.1 Hardware Description 2.1.1 Product Layo
Resumo do conteúdo contido na página número 12
User’s Manual of ICS-10x Figure 2-2 PLANET ICS-100 Front Panel ICS-102 / ICS-102S15 – RS-232 / RS-422 / RS-485 over 10/100Base-FX Figure 2-3 ICS-102 / ICS-102S15 panel layout Figure 2-4 PLANET ICS-102 Front Panel -8-
Resumo do conteúdo contido na página número 13
User’s Manual of ICS-10x 2.1.2 LED Indicators LED Color Function PWR Green Lights to indicate that the Converter is powered on. To indicate that the Fast Ethernet Port is successfully connecting to Lights the network at 10Mbps or 100Mbps TP or Fiber Green Blinks To indicate the Fast Ethernet Port is receiving or sending data Lights To indicate that the UART Port is connected successfully Serial Green Blinks To indicate the UART Port is receiving or sending data 2.1.3 DB9 Pin De
Resumo do conteúdo contido na página número 14
User’s Manual of ICS-10x To press and release the RESET button. The ICS-10X will back to the factory default mode. Be sure that you backup the current configuration of ICS-10X; else the entire configuration will be erased when pressing the “RESET” button. • Press and release the RESET button shortly, the device will be rebooted. • Press the RESET button more than 10 seconds, the device will back to the factory default mode; the entire configuration will be erased. 2.2 Install th
Resumo do conteúdo contido na página número 15
User’s Manual of ICS-10x Figure 2-7 ICS-102 / ICS-102S15 stand alone installation Please refers to APPENDIX-A for detailed wiring information of the ICS-10X. To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the converter. 2.2.2 Chassis Installation and Rack Mounting To install the Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described below. Step 1: Place your ICS-10X on a hard flat surface,
Resumo do conteúdo contido na página número 16
User’s Manual of ICS-10x Step 4: After the brackets are attached to the chassis, use suitable screws to securely attach the brackets to the rack, as shown in Figure 2-2. Step 5: Precede with the steps 4 and steps 5 of session 2.2.1 Stand-alone Installation to connect the network cabling and supply power to your converter. You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty. Figure 2-9 M
Resumo do conteúdo contido na página número 17
User’s Manual of ICS-10x 3. MANAGEMENT This chapter describes how to manage the ICS-10X. Topics include: - Overview - Management methods - Assigning an IP address to the ICS-10X - Logging on to the ICS-10X 3.1 Overview This chapter gives an overview of converter management. The ICS-10X provides a simply WEB browser interface. Using this interface, you can perform various converter configuration and management activities, including: System Network Configuration Operation M
Resumo do conteúdo contido na página número 18
User’s Manual of ICS-10x 3.3 Management Methods The way to manage the ICS-10X: - Web Management via a network or dial-up connection 3.3.1 Web Management The PLANET Web-Smart Media Converter provides a built-in browser interface. You can manage the ICS-10X remotely by having a remote host with web browser, such as Microsoft Internet Explorer, Netscape Navigator or Mozilla Firefox. Using this management method: The ICS-10X must have an Internet Protocol (IP) address accessible for the r
Resumo do conteúdo contido na página número 19
User’s Manual of ICS-10x Figure 3-2 Login screen 1. For security reason, please change and memorize the new password after this first setup. 2. Only accept command in lowercase letter under web interface. -15-
Resumo do conteúdo contido na página número 20
User’s Manual of ICS-10x 4. WEB CONFIGURATION The ICS-10X Web Smart Media Converter provide Web interface for Converter smart function configuration and make the Converter operate more effectively - They can be configured through the Web Browser. A network administrator can manage and monitor the ICS-10x from the local LAN. This section indicates how to configure the Media Converter to enable its smart function. 4.1 Main Menu After a successful login, the main screen appears, the main