Resumo do conteúdo contido na página número 1
User Guide
(Version 1.02)
Resumo do conteúdo contido na página número 2
Contents Copyright Information ............................................................................................................................ii Equinox Warranty Information.............................................................................................................iii Electromagnetic Compatibility (EMC) Compliance ...........................................................................v Technical Support .....................................................
Resumo do conteúdo contido na página número 3
Copyright Information Information in this document is subject to change without notice and does not represent a commitment on the part of the manufacturer. The software described in this document is furnished under license agreement or nondisclosure agreement and may be used or copied only in accordance with the terms of the agreement. It is against the law to copy the software on any medium except as specifically allowed in the license or nondisclosure agreement. The purchaser ma
Resumo do conteúdo contido na página número 4
Equinox Warranty Information This product is guaranteed by Equinox Technologies UK Limited for a period of 12 months (1 year) after the date of purchase against defects due to faulty workmanship or materials. One guarantee covers both parts and labour. Service under the guarantee is only provided upon presentation of reasonable evidence that the date of the claim is within the guarantee period (e.g. completed registration/guarantee card or a purchase receipt). The guarantee is not vali
Resumo do conteúdo contido na página número 5
Equinox Technologies UK Ltd. can not be held responsible for any programming problems which are ‘out of our control’. This type of problem is usually listed in the ‘Errata Sheet’ for the particular device being programmed and is available from the silicon vendor. Information contained in this manual is for guidance purposes only and is subject to change. E&OE. RS232-RS485 Convertor Manual V1.02 28/06/01 iv
Resumo do conteúdo contido na página número 6
Electromagnetic Compatibility (EMC) Compliance The ‘RS-232 to RS-485 Convertor’ is a CE Approved Product. It is designed for use in an ESD controlled environment i.e. development or production. This means, therefore, that the user must ensure that there is no possibility of damage from electrostatic discharge (ESD). Since the devices and equipment to which this product is likely to be connected may well themselves be susceptible to ESD, this should not pose any difficulty. For example
Resumo do conteúdo contido na página número 7
Technical Support It is often the case that users experience problems when installing or using a product for the first time. Equinox are unable to answer technical support questions about this product or its use by telephone. If you have a technical support problem, please consult the following list for help: ? Manual ? On-line help Press for help at any time. The help system is context-sensitive. Simply press on any error message and the Possible causes of the er
Resumo do conteúdo contido na página número 8
Associated Product Documentation This manual provides a detailed description of the ‘RS-232 to RS-485 Convertor’ hardware only. For detailed information about the systems in which this module is used and the associated hardware modules and software support products, please refer to the sources of information listed in the table below. Hardware: Product Documentation PRO101 Programming System Overview \ Getting Started Manual PRO104/108 Programming Overview \ Getting Started Manual
Resumo do conteúdo contido na página número 9
Resumo do conteúdo contido na página número 10
1.0 Overview The RS-232 to RS-485 Convertor module converts RS-232 levels from a PC COM port to RS-485 levels suitable for interfacing with the Equinox PRO101, PRO104 and PRO108 Production ISP programmers. The module provides an optical isolation barrier between the PC COM port and the RS-485 bus which serves to protect the PC from ESD damage. 1.1 System Contents The RS-232 to RS-485 module package should contain the following items: Quantity Item description 1 RS232 – RS485 Conver
Resumo do conteúdo contido na página número 11
2.0 RS232-RS485 Convertor End Panels Figure 2 Number Description Type 1 RS-232 Connector DB9 Female 2 Power Connector 2.5mm Power Connector 3 RS-485 Connector RJ11 4 RS-485 Connector RJ11 5 Traffic Light Status LED’s 3-way LED pack Figure 3 RS232-RS485 Convertor Manual V1.02 28/06/01 2
Resumo do conteúdo contido na página número 12
2.1 RS-232 to RS-485 Status LED Indicators Figure 4 No LED Colour Status Description 1 Red Indicates that the PC has enabled RS-485 transmission. This means that the RS-485 driver has been enabled allowing the convertor to drive the RS-485 line to the remote system. 2 Yellow Indicates that the remote RS-485 system is transmitting data to the PC through the convertor. The LED will flash when data is being transmitted. 3 Green PC is transmitting data to the remote RS-485 system. The
Resumo do conteúdo contido na página número 13
2.3 J1 RS-232 Serial Communications Port Connector type: 9-Way Male D Connector (Female) Purpose: Connects to PC COM port (RS-232) This connector is an RS-232 serial port which connects to a spare RS-232 PC COM (serial) port. The pin-out of this connector is detailed in the table below. The ‘RTS’ pin must be asserted by the PC COM port in order to enable the RS-485 line driver. J1 Pin-out: Pin No. Title RS232 Description RS232 1 DCD Not Connected 2 RXD Receive 3 TXD Transmi
Resumo do conteúdo contido na página número 14
2.4 J2 & J4 Isolated RS-485 Connectors Connector type: FCC68 Socket 6-Way (Accept RJ11 plugs) Purpose: Connects to RS-485 remote system e.g. PRO101/4/8 programmers These two connectors are opto-isolated RS485 connectors for communicating with the remote RS-485 system(s). The connectors are wired in parallel so each socket is the same as the other. The ‘RS-232 to RS-485 Convertor Module’ is supplied with two RJ11 flat cables for connecting between this module and the RS-485 remote
Resumo do conteúdo contido na página número 15
3.0 PRO101 – Multi-Channel RS-485 Operation 3.1 Overview It is possible to network up to 16 PRO101 programmers on an RS-485 network and control them from a single ‘Supervisor PC’ running a single session of the EQTools/ISP-PRO software. This scenario requires that each PRO101 programmer is set to ‘RS-485’ and that a unique ‘Node Address’ is set for each programmer. An RS-232 to RS-485 convertor is required to convert the RS-232 signal from the PC COM port to an optically isolated RS-485
Resumo do conteúdo contido na página número 16
3.2 PRO101 Hardware Installation Instructions • Place the PRO101 programmers side-by-side on a flat surface allowing sufficient space in front of each programmer to place the ‘ISP Interface Modules’ and ‘Target Systems’. • Remove the lid of each programmer by removing the four screws in the lid. • Set the ‘Communications Mode Switch’ (S2) to ‘RS-485’. • Set the Communications Node Address to the required unique address (0 to 15). • Plug the 9-way RS-232 cable into the port on the RS-232
Resumo do conteúdo contido na página número 17
4.0 PRO104 – 4 Channel Eurocard Rack Production ISP System 4.1 Overview The PRO104 programmer contains 4 PPM programming modules on an RS-485 network. These are controlled from a single ‘Supervisor PC’ running the ISP-PRO software. An RS- 232 to RS-485 convertor is required to convert the RS-232 signal from the PC COM port to an optically isolated RS-485 signal suitable for interfacing with the PPM’s on the network. It is possible to expand from 1 up to 4 PRO104’s (16 PPM Boards in total
Resumo do conteúdo contido na página número 18
4.2 PRO104/108 Hardware Installation Instructions • Place the PRO104/108 programmer(s) on a flat surface allowing sufficient space in front of each programmer to place the ‘ISP Interface Modules’ and ‘Target Systems’. • Plug the 9-way RS-232 cable into the port on the RS-232 to RS-485 convertor. Figure 12 • Plug an RS-485 network cable from one of the RS-485 outputs on the RS-485 convertor to the ‘RS-485 Input’ connector on the rear panel of the first PRO104. • Plug another RS-485 n