Resumo do conteúdo contido na página número 1
2H22-08R
SmartSwitch 2208
User’s Guide
Title Page
PWR
CPU
RESET
2H22-08R
16 2 3 4 5
COM
1X 2X 3X 4X 5X 6X 7 8
9032385-02
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR
Resumo do conteúdo contido na página número 4
Notice INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
Resumo do conteúdo contido na página número 5
Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This
Resumo do conteúdo contido na página número 6
Notice SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS THE FE-100F3 FAST ETHERNET INTERFACE MODULE, FPIM-05 AND FPIM-07 FDDI PORT INTERFACE MODULES, AND APIM-29 ATM PORT INTERFACE MODULE USE CLASS 1 LASER TRANSCEIVERS. READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLING OR OPERATING THESE MODULES. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The o
Resumo do conteúdo contido na página número 7
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir
Resumo do conteúdo contido na página número 8
Notice vi 2H22-08R SmartSwitch 2208 User’s Guide
Resumo do conteúdo contido na página número 9
CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Guide......................................................................... 1-1 1.2 Structure of This Guide................................................................ 1-1 1.3 2H22-08R Overview .................................................................... 1-3 1.3.1 Auto-Negotiation ............................................................. 1-3 1.3.2 Connectivity .............................................................
Resumo do conteúdo contido na página número 10
CONTENTS 3.6 Connecting to the Network...........................................................3-7 3.6.1 Connecting a Twisted Pair Segment to the FE-100TX....3-8 3.6.2 Connecting a Fiber Optic Segment to the FE-100FX and FE-100F3..............................................3-10 3.7 Completing the Installation.........................................................3-12 CHAPTER 4 TROUBLESHOOTING 4.1 Using LANVIEW...........................................................................
Resumo do conteúdo contido na página número 11
CONTENTS 5.10 Switch Configuration Screen ..................................................... 5-37 5.10.1 Setting the STA............................................................. 5-40 5.10.2 Setting the Age Time .................................................... 5-41 5.10.3 Setting (Enabling or Disabling) the Port Status ............ 5-41 5.11 Ethernet Interface Configuration................................................ 5-42 5.11.1 Configuring an FE-100TX Interface ................
Resumo do conteúdo contido na página número 12
CONTENTS APPENDIX A SPECIFICATIONS A.1 Device Specifications.................................................................. A-1 A.2 Physical Properties ..................................................................... A-1 A.3 Electrical Specifications .............................................................. A-1 A.4 Environmental Requirements...................................................... A-2 A.5 Input/Output Ports......................................................
Resumo do conteúdo contido na página número 13
CHAPTER 1 INTRODUCTION Welcome to the Cabletron Systems 2H22-08R SmartSwitch 2208 User’s Guide. This guide provides the necessary documentation to install and operate the 2H22-08R SmartSwitch 2208 standalone device and provides information concerning network requirements, installation, troubleshooting, and the use of Local Management. 1.1 USING THIS GUIDE Read through this guide completely to understand the 2H22-08R device features, capabilities, and Local Man
Resumo do conteúdo contido na página número 14
Chapter 1: Introduction Appendix A, Specifications, contains information on functionality and operating specifications, connector pinouts, environmental requirements, and physical properties. Appendix B, FE-100TX, FE-100FX, and FE-100F3 Specifications, contains information about FE-100TX pinouts and information concerning cable types used with the FE-100FX and FE100-F3. Appendix C, Optional Installations and Mode Switch Bank Settings, describes how to install optional Fast Et
Resumo do conteúdo contido na página número 15
2H22-08R Overview 1.3 2H22-08R OVERVIEW The 2H22-08R is a Fast Ethernet standalone device that has six RJ45 switched ports and two optional Fast Ethernet Interface Module ports (100BASE-TX, 100BASE-FX, and 100BASE-F3) that provide twisted pair, multimode, and single mode fiber optic cabling connectivity. PWR CPU RESET 2H22-08R 16 2 3 4 5 COM 7 8 1X 2X 3X 4X 5X 6X Figure 1-1 The 2H22-08R The 2H22-08R supports traditional IEEE 802.1d switching (bridging), IEEE 802.Q switching, and C
Resumo do conteúdo contido na página número 16
Chapter 1: Introduction 1.3.2 Connectivity The 2H22-08R connects to Ethernet networks or workstations through six RJ45 ports on the front panel. These ports support Category 5 unshielded and shielded twisted pair cables of lengths up to 100 meters. These ports are IEEE 802.3u 100BASE-TX compliant. The 2H22-08R has two front panel slots (ports 7 and 8) for optional Fast Ethernet Interface Modules (FE-100TX, FE-100FX, and FE-100F3) to support an uplink to 100 Mbps Fast Ethernet backbo
Resumo do conteúdo contido na página número 17
2H22-08R Overview 1.3.4 Remote Monitoring (RMON) The 2H22-08R supports all Ethernet RMON groups, which include Statistics, Alarms, Events and History as the default groups enabled on all ports, and Capture, Filter, and Host as the groups that are off by default. Cabletron Systems RMON Actions is a vendor-specific extension of RMON and provides the ability to set an “Action” on any SNMP MIB variable. The Action can be triggered by any RMON Event and/or Alarm. The Action
Resumo do conteúdo contido na página número 18
Chapter 1: Introduction 1.4 LOCAL MANAGEMENT Management of the 2H22-08R is accomplished using Local Management tools or remote Simple Network Management Protocol (SNMP) management stations. Out-of-band Local Management is accessible through the RS232 COM port on the front panel using a VT100 terminal, or a remote VT100 terminal emulator via a modem connection, and in-band via a Telnet connection. In-band remote management is possible through any SNMP compliant Network Man
Resumo do conteúdo contido na página número 19
Local Management 1.4.2 Port Redirect Function The port redirect function, also referred to as “Port Mirroring,” is a troubleshooting tool used to map traffic from a single source port or multiple source ports to Destination ports(s) within the chassis. This feature functions at the bit level, which allows all packets, including, if desired, those with errors, to be copied and sent to an analyzer or RMON probe that appears as if it is directly connected to the LAN segment of the
Resumo do conteúdo contido na página número 20
Chapter 1: Introduction 1.5 OPTIONAL FEATURES The optional Fast Ethernet Interface Modules provide fiber optic or twisted pair connectivity for uplinks to 100 Mbps Ethernet backbones or high-speed connections to local servers. The Fast Ethernet Interface Modules are listed in Table 1-1. Table 1-1 Fast Ethernet Interface Modules P/N Description Application Supports Category 5 Unshielded Twisted Pair Uses RJ45 FE-100TX (UTP) cabling, which has an impedance of 85 to connector 111 ohms. Uses SC