Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumo do conteúdo contido na página número 4
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the po
Resumo do conteúdo contido na página número 5
The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present CAUTION: within this unit. RISK OF ELECTRIC SHOCK. This symbol indicates that there are important DO NOT OPEN. operating and maintenance instructions in the literature accompanying this unit. C2653M (6/07) 5
Resumo do conteúdo contido na página número 6
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provi
Resumo do conteúdo contido na página número 7
Product Overview DESCRIPTION The FT82011/FR82011 Ethernet media converter converts 10BASE-T/100BASE-TX data to 100BASE-FX data and vice versa. Designed for point-to-point applications, the FT82011/FR82011 media converter provides one 10BASE-T/100BASE-TX port and one 100BASE-FX fiber port. The FT82011 and FR82011 media converters are used in combination with one another to provide wavelength compatibility. Using wavelength division multiplexing (WDM), bidirectional data is transported in a si
Resumo do conteúdo contido na página número 8
Compatible with other Ethernet equipment: © 10BASE-T/100BASE-TX compatibility with all Pelco and third-party 10BASE-T/ 100BASE-TX Ethernet devices Fiber optic compatibility with all Pelco Ethernet devices that support WDM Environmentally hardened Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for ambient operating temperature, mechanical shock and vibration, humidity with condensation, high-line/low-line voltage conditions, and transient voltage p
Resumo do conteúdo contido na página número 9
MODELS The FT82011 and FR82011 modules consist of the following series of models: Multimode Models:* FT82011MSTR-1 Ethernet media converter, one 10BASE-T/100BASE-TX port, one multimode ST fiber port, one fiber, fiber optic compatibity with FR82011MSTR-1 and other multimode ST Pelco Ethernet devices that support WDM FR82011MSTR-1 Ethernet media converter, one 10BASE-T/100BASE-TX port, one multimode ST fiber port, one fiber, fiber optic compatibility with FT82011MSTR-1 and other multimode ST
Resumo do conteúdo contido na página número 10
FRONT PANEL Figure 2 illustrates the front panel of the FT82011 and FR82011 modules. FT82011 FR82011 Figure 2. Front Panel of FT82011 and FR82011 Modules ì RESET BUTTON (restarts the unit) î 100BASE-FX STATUS LED ï OPTIC FAULT LED (optical signal status/laser status indicator) ñ POWER LED (Pelco badge) For detailed information about the front-panel LEDs, refer to the Troubleshooting section. 10 C2653M (6/07)
Resumo do conteúdo contido na página número 11
REAR PANEL Figure 3 illustrates the rear panel of the FT82011 and FR82011 modules. FT82011 FR82011 Figure 3. Rear Panel of FT82011 and FR82011 Modules (SC Fiber Connector Shown) ì RACK POWER/ALARM CONNECTOR, 4-pin connector for power/alarm connection of rack- mounted module î STAND-ALONE POWER CONNECTOR, 2-pin connector for power connection of stand-alone module; removable mating connector with screw terminals (not shown) ï 10BASE-T/100BASE-TX PORTS 1-4, RJ-45 connectors ñ FIBER OPTIC PORT,
Resumo do conteúdo contido na página número 12
Installation PACKAGE CONTENTS The following items are supplied: 1 FT82011 or FR82011 module 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4-40 x 0.250-inch Phillips pan head screws with lock washers (for attachment of single module to wall) 1 FT82011/FR82011 Fiber Transmitter and Receiver Installation manual (this manual) SETTING 10BASE-T/100BASE-TX PORT
Resumo do conteúdo contido na página número 13
Using the TX Mode switch, you can do the following: Enable autonegotiation or select (force) a specific data rate and duplex mode: Enabling autonegotiation allows the FT82011/FR82011 module to automatically negotiate with the device to which the port is connected for data rate and duplex modes of operation: 10 Mbps or 100 Mbps data rate and half-duplex or full-duplex mode. The highest common denominator of operational modes is automatically selected. Autonegotiation is enabled by default.
Resumo do conteúdo contido na página número 14
MOUNTING The FT82011/FR82011 module can be mounted into a rack or can be used as a stand-alone module. As a stand-alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set the modes of operation for the 10BASE-T/100-BASE-TX port—if required—before mounting the FT82011/FR82011 module into a rack or onto a wall. For information about setting the port modes of operation, refer to the Setting 10BASE-T/100BASE-T
Resumo do conteúdo contido na página número 15
Mounting the FT82011/FR82011 Module Using the Wall Clip NOTE: Before mounting the FT82011/FR82011 module to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for making the various rear-panel cable connections. To attach the FT82011/FR82011 module to a wall using the supplied wall clip, refer to Figure 5 and do the following: 1. Using the two vertical or horizontal wall-mounting holes, attach the wall clip to a wall using two screws (not provided).
Resumo do conteúdo contido na página número 16
CONNECTIONS Connections to the FT82011/FR82011 module are made on the rear panel of the unit (refer to Figure 6). POWER/ALARM CONNECTION FOR RACK-MOUNTED MODULE POWER CONNECTION FOR STAND-ALONE MODULE FIBER OPTIC CABLE 10/100 NETWORK CABLE Figure 6. FT82011/FR82011 Module Connections As illustrated in Figure 6, FT82011/FR82011 connections consist of the following: Power connection NOTES: A 12 VDC or 24 VAC power supply can be used to power the module when used as a stand-alone unit. A
Resumo do conteúdo contido na página número 17
Fiber connection NOTE: Fiber port A of the FT82011 module connects to fiber port B of the FR82011 module or of any other Pelco Ethernet switch that supports wavelength division multiplexing (WDM). Similarly, fiber port B of the FR82011 module connects to fiber port A of the FT82011 module or of any other Pelco Ethernet switch that supports WDM. Note that port A and port B provide wavelength compatibility: Multimode fiber port A transmits data at 1310 nm and receives data at 850 nm. Mult
Resumo do conteúdo contido na página número 18
Troubleshooting LED indicators on the front and rear panels of the FT82011/FR82011 module allow you to monitor operational status: LED indicators on the front panel allow you to monitor operating power, 100BASE-FX port status, and optic signal/laser status. Refer to Table B for information about the front-panel indicators and associated troubleshooting guidelines. LED indicators on the rear panel allow you to monitor RJ-45 10BASE-T/100BASE-TX port status. Refer to Table C for information
Resumo do conteúdo contido na página número 19
Table B. Troubleshooting with Front-Panel Indicators (Continued) Indicator Color Meaning Possible Cause Corrective Action 100BASE-FX Status LED ( ) (Continued) Red Ethernet link NOTE: In addition to a red 100BASE-FX Do any of the following to Status LED, the Optic Fault LED is green or restore the link: is down. flashing red and the left RJ-45 Port Status If a laser fault has LED (Link/Activity) is not lit. occurred, refer to the A link-down detection condition exists due to Optic Fault
Resumo do conteúdo contido na página número 20
Table B. Troubleshooting with Front-Panel Indicators (Continued) Indicator Color Meaning Possible Cause Corrective Action Optic Fault LED ( ) (Continued) Red Ethernet link NOTE: In addition to a red Optic Fault LED, Do any of the following to is down. the 100BASE-FX LED and the left RJ-45 Port restore the link: Status LED (Link/Activity) LED are not lit. Check the connections A link-down detection condition exists due to of the fiber optic cable. any of the following fault conditions: If