Resumo do conteúdo contido na página número 1
®
Breakout Panels for
VA6000 Series Switcher
and CM8500 Matrix System
Installation/Operation
Manual C842M (9/96)
PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827
Resumo do conteúdo contido na página número 2
TABLE OF CONTENTS Section Page 1.0 WARNINGS ........................................................................................................................................1 2.0 SCOPE ...............................................................................................................................................2 3.0 DESCRIPTION ...................................................................................................................................2 4.0 INSTALLATI
Resumo do conteúdo contido na página número 3
INSTALLATION/OPERATION MANUAL BREAKOUT PANELS FOR VA6000 SERIES SWITCHER AND CM8500 MATRIX SYSTEM 1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and
Resumo do conteúdo contido na página número 4
2.0 SCOPE As was the case for the VA6000, all telescoped inputs for breakout panels used with the CM8500 are con- The information contained within this manual covers nected via the appropriate onboard header to existing the installation and operation of the Alarm Breakout “D” type connectors on the rear of the CM8500 Matrix Panels for the VA6000 Series Switcher and the Alarm, bay via ribbon cables. Wiretron and Relay Breakout Panels for the CM8500 Matrix system. The 24 inch (.609 m) and 120 inc
Resumo do conteúdo contido na página número 5
Figure 1. Alarm Breakout Panel Assembly Information–VA6000 Series Pelco Manual C842M (9/96) 3 ALARM BREAKOUT PANEL (PCB9000617) WIRING SCHEMATIC J1 J2 Mounting Plate CABLE ASSEMBLIES Keyed connectors 25-PIN Cable 15-PIN Cable PCB Layout
Resumo do conteúdo contido na página número 6
The table below lists the pin-out relationship between the alarm panel header, J2, and the 15-pin connec- tor on the rear of the VA6000 switcher for 8 input alarms. The pattern serves equally well for VA models with 4 input alarms: the first 4 Pin Numbers correspond to like numbered ALM numbers, with pins 5-10 unused and pins 11-15 serving the same functions as in the 8 input VA6000 Switcher model. Alarm Pin-outs 1-8/VA6000 J2 Header Pin-out on Alarm Breakout Rear Panel Connector
Resumo do conteúdo contido na página número 7
The table below lists the pin-out relationship between the alarm panel header, J1, and the 25-pin con- nector on the rear of the VA6000 switcher for 20 input alarms. The pattern serves equally well for VA models with 12 input alarms: the first 12 Pin Numbers correspond to like numbered ALM numbers with pins 13-20 unused and pins 21-25 serving the same functions as in the 20 input VA6000 Switcher models. Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 J1 Header Pin-out on Alarm Breakout for CM8500 ALM
Resumo do conteúdo contido na página número 8
Figure 4. Alarm Breakout Panel Assembly Information–CM8500 Series 6 Pelco Manual C842M (9/96) WIRING SCHEMATIC PCB LAYOUT Mounting Plate CABLE ASSEMBLY ALARM BREAKOUT PANEL (PCB9000582)
Resumo do conteúdo contido na página número 9
The table below lists the pin-out relationship between the alarm panel header, J1, and P4 on the CM8500 for the first 16 alarms. The pattern serves equally well for alarms 17-32: P4 becomes P3 and the listed alarms go from 17-32 instead of 1-16. Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 J1 Header Pin-out on Alarm Breakout for CM8500 ALM # Pin Number Pin Number Alarm Com 11 ... 1 ... 20 2 22 ... 3 ... 21 4 33 ... 5 ... 22 6 44 ...
Resumo do conteúdo contido na página número 10
Figure 6. Wiretron Breakout Panel Assembly Information–CM8500 Series 8 Pelco Manual C842M (9/96) WIRING SCHEMATIC Mounting Plate WIRETRON BREAKOUT PANEL RIBBON CABLE (PCB9000583)
Resumo do conteúdo contido na página número 11
The table below lists the pin-out relationship between the wiretron panel header, J1, and P5 on the CM8500 for the first 16 wire control positions. The pin mappings serve equally well for wire controls 17-32: P5 becomes P6 and the listed WIR numbers go from 17-32 instead of 1-16. J1 Header Pin-out on Wiretron Breakout Wire Control Pin-outs 1-16/CM8500 Panel for CM8500 Rear Panel-P5 WIR # Pin Number Pin Number 11 ... 1 ... 2 3 23 ... 5 ... 4 7 35 ... 9 ...
Resumo do conteúdo contido na página número 12
Figure 8. Wiretron Breakout Panel Assembly Information–CM8500 Series 10 Pelco Manual C842M (9/96) WIRING SCHEMATIC Mounting Plate RELAY BREAKOUT PANEL (PCB9000581) RIBBON CABLE ASSEMBLY PCB LAYOUT
Resumo do conteúdo contido na página número 13
Figure 9. Installation Configuration for the CM8500 Wiretron Breakout Panel Figure 10. Rack Panel Mounting Plate Dimensions Pelco Manual C842M (9/96) 11
Resumo do conteúdo contido na página número 14
The table below lists the pin-out relationship between the relay panel header, J1, and P1 on the CM8500 for the first 16 relay output positions. The pin mappings serve equally well for relay outputs 17-32: P1 becomes P2 and the listed RELAY numbers go from 17-32 instead of 1-16. Relay 1-16 Pin-outs CM8500 J1 Header Pin-out on Relay Rear Panel-P1 Breakout Panel for CM8500 RELAY # Pin Number Pin Number NC NO COM 1 ... ... 1 1 ... 2 ..
Resumo do conteúdo contido na página número 15
5.0 MODELS CM8500-WPNL-2 Wiretron breakout panel for up to 16 outputs/panel; 2-foot (.609 VA6008-APNL-2 VA6000 alarm breakout panel m) inter connecting ribbon cable for up to 8 alarm inputs; 2-foot supplied. (.609 m) interconnecting ribbon cable supplied. CM8500-WPNL-10 Same as CM8500-WPNL-2, ex- cept 10-foot (3.048 m) intercon- VA6008-APNL-10 Same as VA6008-APNL-2, ex- necting ribbon cable. cept 10-foot (3.048 m) intercon- necting ribbon cable. CM8500-RPNL-2 Relay breakout panel for up to 16 o
Resumo do conteúdo contido na página número 16
7.0 WARRANTY AND RETURN INFORMATION WARRANTY RETURNS Pelco will repair or replace, without charge, any merchandise proved In order to expedite parts returned to the factory for repair or credit, please defective in material or workmanship for a period of one year after the date call the factory at (800) 289-9100 or (559) 292-1981 to obtain an of shipment. authorization number (CA number if returned for credit, and RA number if returned for repair). Exceptions to this warranty are as noted below