Resumo do conteúdo contido na página número 1
HSIM-A6DP
User’s Guide
HSIM-A6DP
APIM 1 APIM 2
R R
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR
Resumo do conteúdo contido na página número 4
Notice DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. VCCI NOTICE
Resumo do conteúdo contido na página número 5
Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This
Resumo do conteúdo contido na página número 6
Notice SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS THE FE-100F3 FAST ETHERNET INTERFACE MODULE, FPIM-05 AND FPIM-07 FDDI PORT INTERFACE MODULES, AND APIM-29 ATM PORT INTERFACE MODULE USE CLASS 1 LASER TRANSCEIVERS. READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLING OR OPERATING THESE MODULES. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The
Resumo do conteúdo contido na página número 7
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir
Resumo do conteúdo contido na página número 8
Notice vi HSIM-A6DP User’s Guide
Resumo do conteúdo contido na página número 9
CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual....................................................................... 1-2 1.2 Document Conventions ............................................................... 1-2 1.3 Overview...................................................................................... 1-3 1.4 Features ...................................................................................... 1-3 1.5 Specifications ...........................................
Resumo do conteúdo contido na página número 10
Contents 3.8 The ATM Redundancy Configuration Screen ............................3-15 3.8.1 ATM Redundancy Configuration Screen Fields ............3-16 3.8.2 Setting the Redundancy Status.....................................3-18 3.8.3 Setting the Primary Port ................................................3-18 3.8.4 Setting the Active Port...................................................3-18 3.8.5 Setting the Activation of Redundant Port Field..............3-19 3.8.6 Setting the Revert to
Resumo do conteúdo contido na página número 11
Contents 3.18 Enabling the Bandwidth Allocation Mode Feature..................... 3-54 3.19 Creating PVCs with the Bandwidth Allocation Mode Enabled... 3-57 3.19.1 ATM Connection Setup Screen Fields.......................... 3-58 3.20 The Add/Delete Entry Screen.................................................... 3-60 3.20.1 Add/Delete Entry Screen Fields.................................... 3-60 3.20.2 Adding an Entry (PVC) ................................................. 3-62 3.20.3 Mod
Resumo do conteúdo contido na página número 12
Contents x HSIM-A6DP User’s Guide
Resumo do conteúdo contido na página número 13
CHAPTER 1 INTRODUCTION Welcome to the Cabletron Systems HSIM-A6DP User’s Guide. This manual provides the following information: • Describes HSIM-A6DP features • Explains how to install the HSIM-A6DP in a Cabletron Systems interface module or standalone hub • Outlines specifications for the Cabletron Systems Asynchronous Transfer Mode (ATM) High Speed Interface Module (HSIM) The HSIM-A6DP provides additional connectivity/functionality to various Cabletron Systems interface modules
Resumo do conteúdo contido na página número 14
Chapter 1: Introduction 1.1 USING THIS MANUAL Read through this manual completely to familiarize yourself with its content and to gain an understanding of the features and capabilities of the HSIM-A6DP. The following list provides an overview of each section of this manual: Chapter 1, Introduction, outlines the contents of this manual, describes HSIM-A6DP features and concludes with a list of related manuals. Chapter 2, Installation, describes how to install ATM Port
Resumo do conteúdo contido na página número 15
Overview 1.3 OVERVIEW The HSIM-A6DP extends the functionality of your Cabletron Systems interface module or standalone hub to include remote uplink capability. It allows remote connectivity using ATM technology. Two APIMs can be installed in the HSIM-A6DP, to provide redundant ATM links from the HSIM to a switched ATM network. Cabletron Systems provides a variety of APIMs that let you select the configuration of your choice. If port redundancy is not a requirement, then only o
Resumo do conteúdo contido na página número 16
Chapter 1: Introduction 1.5 SPECIFICATIONS This section describes environment specifications and safety requirements for the HSIM-A6DP. Cabletron Systems reserves the right to change these specifications at any time without notice. Environment Operating Temperature: 5 C to 40 C (41 F to 104 F) Storage Temperature: -30 C to 73 C (-22 F to 164 F) Operating Relative Humidity: 5% to 90% (non-condensing) Regulatory Compliance Safety: UL 1950, CSA C22.2 No. 950
Resumo do conteúdo contido na página número 17
Getting Help 1.7 GETTING HELP If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center: Phone (603) 332-9400 Internet mail support@ctron.com FTP ctron.com (134.141.197.25) Login anonymous Password your email address BBS (603) 335-3358 Modem setting 8N1: 8 data bits, No parity, 1 stop bit For additional information about Cabletron Systems or
Resumo do conteúdo contido na página número 18
Chapter 1: Introduction 1-6 HSIM-A6DP User’s Guide
Resumo do conteúdo contido na página número 19
CHAPTER 2 INSTALLATION This chapter contains instructions for the following tasks: • Unpacking the HSIM (Section 2.1) • Installing APIMs (Section 2.2) • Installing an HSIM (Section 2.3) To install the HSIM and APIMs, you need the following tools: • Antistatic wrist strap (provided with the 6C105 chassis or standalone hub) • Phillips screwdriver 2.1 UNPACKING THE HSIM Unpack the HSIM as follows: The HSIM-A6DP and the host module or hub are sensitive to static discharges. Use an antistatic wr
Resumo do conteúdo contido na página número 20
Chapter 2: Installation 2.2 INSTALLING APIMs Only qualified personnel should install or service this unit. To install an APIM into the HSIM-A6DP, refer to Figure 2-1 and Figure 2-2 and perform the following steps: 1. Attach the antistatic wrist strap (refer to the instructions on the antistatic wrist strap package). 2. Remove and save the three faceplate screws attaching the faceplate to the HSIM. Remove the HSIM faceplate. 3. Remove and save the three screws from the HSIM standoffs. Remove t