Resumo do conteúdo contido na página número 1
T TD DC C- -1 10 00 0/ /2 20 00 0
U Us se er r’’s s G Gu uiid de e
Resumo do conteúdo contido na página número 2
2 2
Resumo do conteúdo contido na página número 3
Index Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 General Editing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 Timing Mechanism Components - - - - - - - - - - - - - - - - - - - - - - - - - - 5 Mother Board Components - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Daughter Board Components - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 Power-Up Diagnostics - - - - - - - - - - - - - - - -
Resumo do conteúdo contido na página número 4
Introduction The Toro TDC-100/200 combines modular flexibility, ease of use and increased programmability in a single controller. Modularity means flexibility. The TDC-100/200 can control up to 200 stations. The intuitive user interface is easy to use and includes a backlight for improved visibility in low-light conditions, yet it is completely viewable in direct sunlight. The faceplate’s combination of menu keys, navigation arrows and Input Dial allows for easy menu navigation and quick setti
Resumo do conteúdo contido na página número 5
Timing Mechanism TDC-100/200 3 2 1 4 56 7 8 9 HOME MANUAL SCHEDULED DIAGNOSTICS STATION WATERING WATERING SETTINGS 10 11 12 13 14 %ADJUST START PAUSE/ STOP SYSTEM RESUME SETTINGS 1 Left and Right Arrows allow you to select the next entry field within the same menu line. Any changes will be saved after you exit that entry field. 2 Up and Down Arrows allow you to scroll up and down through the menu items. 3 LCD Panel is the display screen. 4 Input Dial allows you to scroll through the value select
Resumo do conteúdo contido na página número 6
1 10 Mother Board 2 3 4 9 11 5 6 7 8 12 13 14 15 16 Mother Board Components Daughter Board 1 Station Watering LED 2 Pump ON LED 3 Pump Pressure LED 4 Rain Sensor LED 5 Power LED 6 PC Connection LED 7 Tx LED 17 8 Rx LED 9 Mother Board Fuse, 3.15A Slow-Blow 10 Timing Mechanism Cable Socket 11 RS-232 Fiber/Wire Switch 12 Pump Output 13 Pump Pressure Input 14 Rain Switch Input 15 RS-232 Input Daughter Board Components 16 Power LED 17 Daughter Board Fuse (8), 3.15A Fast-Blow 6 6
Resumo do conteúdo contido na página número 7
Power-Up Diagnostics Upon power-up, the controller will display: TDC–100/200 System Booting The TDC-100/200 will initiate a diagnostic test automatically during power-up. This function will take approximately ten seconds and it can not be bypassed. If a problem is detected during the diagnostic test, it will be indicated on the display. When completed, information will be displayed momentarily on the screen for five seconds. This status information can not be edited. The information is as follow
Resumo do conteúdo contido na página número 8
System Settings System Settings allows you to set controller parameters such as Time, Date and Language. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing. Language: – Default, English. Future option, Spanish, French, German and Italian. Clock Set: – Use this function to set the current time. Clock Mode: – Use this function to select the clock mode betwe
Resumo do conteúdo contido na página número 9
Hold For: – Use this function to suspend controller operation and choose the suspension duration from Today, 02-30 days, Permanent or None. Reset Prg’s: – Use this function to reset all controller irrigation program by selecting Yes. After selecting Yes, press the Up or Down Arrows to activate. The following will display: Reset All Programs to defaults 05 STOP to escape All program data will be erased after a successful reset. Reset Sta’s: – Use this function to reset all station settings by sel
Resumo do conteúdo contido na página número 10
Station Settings Station Settings allows you to set parameters specific to each station. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow Keys to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing. S01 – Select the station you want to edit in this field. Choose from S100 100% 1STSTLAWN Station 01 through the controller maximum station count of Decoder Addr: 38684 200. Dec Sta: 4 Path: 2 Disable: No 10
Resumo do conteúdo contido na página número 11
Scheduled Watering The TDC-100/200 features 10 fully-independent resident programs. With two types of programs to select from, you can further custom fit your irrigation programs to any landscape. • Standard Irrigation Program will activate a station or group of stations with six start times on a daily basis. Each station will water for the duration specified in hours, minutes and seconds. Percent adjust and maximum number of simultaneous activate stations per program can be specified in this pr
Resumo do conteúdo contido na página número 12
8. Press the Down Arrow to advance the cursor to the Sta Dly: field. Use the Left and Right Arrow Keys to navigate between the Hour and Minute fields. Use Input Dial to set the Station Delay duration. Station delay is the wait period when a station finished watering and when the next station is activated. In most situations, station delay is used to allow slow -shutting valves time to fully close before activating another station and also to allow the water source, such as a well, to recover. Fo
Resumo do conteúdo contido na página número 13
Grow In Irrigation Program Setting: Grow In Irrigation Program example: Create program 3 with stations 21–30 for 5 minutes each with no percent adjustment. Set the start time at 6:30 am and the end time at 4:00 pm. Set the delay for 2 hours and 15 minutes and the maximum simultaneous active station to 5. 1. Press the Scheduled Watering Key . The cursor is initially located at the program selection field. Use the Input Dial to select the program (P01–P10) you want to create or modify. For this e
Resumo do conteúdo contido na página número 14
Manual Watering The Manual Watering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to troubleshoot each station for proper operation. Pressing the Manual Watering Key will access three manual irrigation functions; Multi-Manual, Syringe and Program. M-Manual - Select M-Manual to activate a station or group of stations with a specified runtime. Multi-Manual Station Activation Directions Manual station activation example: Activate stat
Resumo do conteúdo contido na página número 15
Syringe - Choose Syringe to activate all the stations in a selected irrigation program for a specified runtime. Note: The Maximum number of simultaneous stations set in the program still applies. Manual Syringe Activation Directions Syringe activation example: Manually activate all the stations in Program 3 for 2 minutes each. Note: An irrigation program must be configured to activate Manual Syringe. 1. Press the Manual Watering Key . 2. The cursor should be located in the Manual field. Use th
Resumo do conteúdo contido na página número 16
% (Percent) Adjust The percent adjust function allows you to fine tune irrigation programs. With weather conditions changing constantly, Percent Adjust allows you to tune your system easily without changing all the values in the program. Important: The settings do not override each other, instead, they multiple each other to get the effective adjustment. Example: Controller is set at 150%, Program is set at 125% and Station is set at 90%. The effective watering adjustment is calculated to be 1.5
Resumo do conteúdo contido na página número 17
Pause / Resume Key The Pause command is used to suspend active program or manual irrigation. The Pause function allows the user to specify the pause duration. Pause / Resume Function Directions Pause function example: Program 01 has been manually activated. Pause program 01 for 30 minutes. 1. Press the Pause key. 2. Use the Input Dial to select All, M-Man or Prg:XX (XX = the program number). If multiple programs are active, use the Right Arrow key to tab to the program number field before usin
Resumo do conteúdo contido na página número 18
Pause Function TDC-100/200 Action Pause Program XX Allow the start of other programs, multi-manuals and syringe. If the start time of the paused program occur’s again while still on Pause, that runtime will be stacked (delayed until the first occurrence is completed). If Program XX is already on Pause or Pause All is in effect, the new pause time-out will override the remaining pause time for program XX. Pause Multi-Manual Allows any program or syringe start. If a new multi-manual is activated,
Resumo do conteúdo contido na página número 19
Diagnostics The diagnostics function allows the user to monitor Radio Link status, check the firmware version, troubleshoot stations using the Sequence Stations options, monitor the system’s water usage, monitor all system’s sensor status, monitor system’s voltages, check alarm status, clear alarms and execute a self diagnostics to the system. Use this menu to check Use this menu to clear Menu: Station Alarms Menu: Clear Alarms alarm codes that have alarm codes once it’s No Station Alarms Last c
Resumo do conteúdo contido na página número 20
Fuse & Circuit Breaker Specifications Power Supply: 1.5A On/Off Switch/Circuit Breaker – Main Power Input 3.15A Fuse (Slow-Blow) – Field Output Mother Board: 3.15A Fuse Controller Specifications Line Voltage: 100, 220 or 240 VAC 50/60 Hz, 98 VA Current Draw (no load): 0.21A @ 100-120 VAC, 60 Hz or 0.10A @ 200-240 VAC, 50 Hz Current Draw (maximum load): 0.91A @ 100-120 VAC, 60 Hz or 0.45A @ 200-240 VAC, 50 Hz Current Load: 28 VAC Maximum Current Available for Load: 3.15A (90 VA) Maximum Load Per