Resumo do conteúdo contido na página número 1
HP ProLiant DL360 Generation 4p Server
(SAS Model)
User Guide
April 2005 (First Edition)
Part Number 391001-001
Resumo do conteúdo contido na página número 2
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft, Windows, and Windows NT are U.S. registered trademar
Resumo do conteúdo contido na página número 3
3 Contents Server component identification 7 Front panel components.......................................................................................................................7 Front panel LEDs and buttons..............................................................................................................8 Rear panel components ......................................................................................................................10 Rear panel LEDs a
Resumo do conteúdo contido na página número 4
4 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Installing the server into the rack .......................................................................................................36 Powering up and configuring the server ............................................................................................38 Installing the operating system...........................................................................................................39 Registering
Resumo do conteúdo contido na página número 5
Contents 5 HP Systems Insight Manager..................................................................................................74 Redundant ROM support........................................................................................................75 USB support and functionality ...............................................................................................76 Diagnostic tools ................................................................................
Resumo do conteúdo contido na página número 6
6 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Regulatory compliance notices 113 Regulatory compliance identification numbers................................................................................113 Federal Communications Commission notice..................................................................................114 FCC rating label....................................................................................................................114 Clas
Resumo do conteúdo contido na página número 7
7 Server component identification In this section Front panel components..................................................................................................................7 Front panel LEDs and buttons........................................................................................................8 Rear panel components.................................................................................................................10 Rear panel LEDs and buttons ....
Resumo do conteúdo contido na página número 8
8 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Description 2 Multi-bay (DVD/CD/Diskette) drive 3 Power on/Standby button and system power LED 4 Front USB port 5 Hard drive bay 4 6 Hard drive bay 3 7 Hard drive bay 2 Front panel LEDs and buttons Item Description Status 1 Power On/Standby button Green = System is on. and system power LED Amber = System is shut down, but power is still applied. Off = Power cord is not attached, power supply failure ha
Resumo do conteúdo contido na página número 9
Server component identification 9 Item Description Status 3 Internal health LED Green = System health is normal. Amber = System is degraded. To identify the component in a degraded state, refer to "System board LEDs (on page 14)." Red = System critical. To identify the component in a critical state, refer to "System board LEDs (on page 14)." Off = System health is normal (when in standby mode). 4 External health LED Green = Power supply health is normal. (power supply) Amber = Power
Resumo do conteúdo contido na página número 10
10 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Rear panel components Item Description 1* PCI-X expansion slot 1, 64-bit/133-MHz 3.3V (optional PCI Express slot 1, x8) 2* PCI-X expansion slot 2, 64-bit/133-MHz 3.3V (optional PCI Express slot 2, x8) 3 Power supply bay 2 4 Power supply bay 1 (populated) 5 Rear USB connector 6 10/100/1000 NIC 2 7 10/100/1000 NIC 1 8 iLO management port 9 Mouse connector 10 Keyboard connector 11 Video connector 12 Serial conn
Resumo do conteúdo contido na página número 11
Server component identification 11 * Depending on the model of the server, slot 1 or slot 2 will be pre-populated with a storage controller. If the expansion slot is populated with the standard PCI-X storage controller card, it should not be converted to PCI Express. Rear panel LEDs and buttons Item Description Status 1 iLO activity Green = Activity exists. Flashing green = Activity exists. Off = No activity exists. 2 iLO link Green = Link exists. Off = No link exists. 3 10
Resumo do conteúdo contido na página número 12
12 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Description Status 6 10/100/1000 Green = Activity exists. NIC 1 activity Flashing green = Activity exists. Off = No activity exists. 7 Unit Identification Blue = Identification is activated. button/LED Flashing blue = System is being managed remotely. Off = Identification is deactivated. System board components Item Description 1 DIMM slots (1-6) 2 NMI switch 3 System maintenance switch (SW2) 4 Proce
Resumo do conteúdo contido na página número 13
Server component identification 13 Item Description 7 Optical device/multi-bay connector 8 Power supply connector 9 Power supply signal connector 10 Remote management connector 11 PCI riser board assembly connector (for slot 2 riser board) 12 PCI riser board assembly connector (for slot 1 riser board) 13 System battery System maintenance switch Position Default Function S1 Off Off = iLO security is enabled. On = iLO security is disabled. S2 Off Off = System configuration ca
Resumo do conteúdo contido na página número 14
14 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide NMI switch The NMI switch allows administrators to perform a memory dump before performing a hard reset. Crash dump analysis is an essential part of eliminating reliability problems, such as hangs or crashes in operating systems, device drivers, and applications. Many crashes freeze a system, requiring you to do a hard reset. Resetting the system erases any information that would support root cause analysis. Systems runn
Resumo do conteúdo contido na página número 15
Server component identification 15 Item LED Description Status 3 DIMM 4B failure Amber = DIMM has failed. Off = DIMM is operating normally. 4 DIMM 3B failure Amber = DIMM has failed. Off = DIMM is operating normally 5 DIMM 2A failure Amber = DIMM has failed. Off = DIMM is operating normally. 6 DIMM 1A failure Amber = DIMM has failed. Off = DIMM is operating normally 7 Overtemperature Amber = System has reached cautionary or critical temperature level. Off = Temperature is OK. 8 P
Resumo do conteúdo contido na página número 16
16 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item LED Description Status 15 System diagnostic Refer to the HP Remote Lights-Out Edition II User Guide on the Documentation CD. 16 Online spare Amber = Failover has occurred. Online spare memory memory is in use. Green = Online spare memory is enabled, but not in use. Off = Online spare memory is disabled. 17 Riser interlock Amber = PCI riser assembly is not seated. Off = PCI riser assembly is seated. System LED
Resumo do conteúdo contido na página número 17
Server component identification 17 System LED Internal Status and color Health LED color Processor Red Processor types are mismatched. failure, both sockets (Amber) PPM failure Red PPM has failed. (Amber) DIMM failure, Red DIMM in slot X has failed. slot X (Amber) DIMM in slot X is an unsupported type, and no valid memory exists in another bank. Amber DIMM in slot X has reached single-bit correctable error threshold. DIMM in slot X is in a pre-failure condition.
Resumo do conteúdo contido na página número 18
18 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide System LED Internal Status and color Health LED color Power supply Red The power supply signal cable is not connected to the system signal interlock board. (Amber) Internal USB connector The front internal USB connector is located in the processor zone fan module. Item Description 1 USB connector 2 Front internal/external selector switch For more information, refer to "Internal USB Functionality (on page
Resumo do conteúdo contido na página número 19
Server component identification 19 SAS and SATA device numbers Identifying the status of a hard drive When a drive is configured as a part of an array and connected to a powered-up controller, the condition of the drive can be determined from the illumination pattern of the hard drive status lights (LEDs).
Resumo do conteúdo contido na página número 20
20 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide SAS and SATA hard drive LED combinations 1 - Fault/UID LED 2 - Online/Activity Interpretation (amber/blue) LED (green) Flashing amber and On, off, or flashing The drive has failed, or a predictive failure alert has been blue received for this drive; it also has been selected by a management application. Blue On, off, or flashing The drive is operating normally, and it has been selected by a management application.