Resumo do conteúdo contido na página número 1
INST ALLA TION
®
090 Series Camclosure
Indoor Integrated
Camera System
Surface Mount/In-Ceiling
C2462M-D (3/08)
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Contents Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Parts List. . .
Resumo do conteúdo contido na página número 4
List of Illustrations 1 How to Remove the Dome Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 Ceiling/Wall Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3 Concrete Ceiling/Wall Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4 Ceiling Tile Installation. . . . . . . . . . . .
Resumo do conteúdo contido na página número 5
Important Safety Instructions 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. Use only installation methods and materials capable of supporting four times the maximum specified load. Regulatory Notices This device complies with Part 15 o
Resumo do conteúdo contido na página número 6
Description ® The ICS090 Series Camclosure integrated camera system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a ceiling or wall. Prior to the installation of your new system, thoroughly familiarize yourself with the information in this manual. PARTS LIST The following materials are supplied with the 090 Series Camclosure integrated camera system: Qty Description 1 Assembled ICS090 Series Camcl
Resumo do conteúdo contido na página número 7
Remove the Dome Bubble Turn the dome bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a nonabrasive surface. If the unit is supplied with a dome liner, remove the liner before installing the unit. To remove the liner, gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the bubble after the installation has been completed following installation.. Figure 1. How to Remove the Dome Bubble C2462M-D (3/08) 7
Resumo do conteúdo contido na página número 8
Install the Back Box The installation methods for the ICS090 Series include the following options: • Mount to the surface of a ceiling or wall • Install in a suspended ceiling • Install in a fixed ceiling or wall • Mount to the surface of a 4S standard electrical box • Install in a 4S deep electrical box Select the best method for your installation and refer to the following pages for instructions. INSTALLATION TO SURFACE OF A CEILING/WALL Refer to Figure 2 for the following steps. Refer to Fi
Resumo do conteúdo contido na página número 9
4. Use the 6-32 toggle bolts (not supplied) to attach the surface mount ring and back box to the mounting surface, refer to Figure 2. NOTE: For a concrete ceiling/wall installation, use 8-32 mounting hardware (not supplied), refer to Figure 3. Figure 2. Ceiling/Wall Installation Figure 3. Concrete Ceiling/Wall Installation C2462M-D (3/08) 9
Resumo do conteúdo contido na página número 10
IN-CEILING INSTALLATION: SUSPENDED CEILING Refer to Figure 4 and complete the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a 4-inch diameter hole in the ceiling tile. 3. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. NOTE: Do not discard the su
Resumo do conteúdo contido na página número 11
STANDOFF BACK BOX SURFACE MOUNT RING Figure 5. How to Remove Surface Mount Ring from Back Box AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer, connect one side of the transformer to the red wire on all units, and then connect the other side of the transformer to the black wire on all units. Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switch
Resumo do conteúdo contido na página número 12
IN-CEILING INSTALLATION: FIXED CEILING/WALL Refer to Figure 6 and complete the following steps. 1. Cut a 4-inch diameter hole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 3. Connect the video cable/wires. BNC: Connect the BNC connector from the
Resumo do conteúdo contido na página número 13
INSTALLATION TO THE SURFACE OF A 4S STANDARD ELECTRICAL BOX Refer to Figure 7 and complete the following steps. 1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 2. Connect the video cable/wires. BNC: Connect the BNC connector from the Camclosure to a mating BNC connector. Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -. 3. Connect the power wires. Table D. Power Input: 4S Standard Electrical Box Installation Voltage Red
Resumo do conteúdo contido na página número 14
INSTALLATION IN A 4S DEEP ELECTRICAL BOX Refer to Figure 8 and complete the following steps. 1. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 2. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 3. Connect the video cable/wires. B
Resumo do conteúdo contido na página número 15
Camera Positioning Manually rotate and tilt the camera module to position the camera. Do not over-rotate the module. WARNING: Excessively turning the module in one direction could result in damage to the wiring. ì Tilt 140° î Pan 360° ï Rotation 360° Figure 9. Positioning the Camera C2462M-D (3/08) 15
Resumo do conteúdo contido na página número 16
Camera Adjustments SWITCH SETTINGS SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions, to optimize the picture detail when there are bright s
Resumo do conteúdo contido na página número 17
VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. To eliminate vertical roll, reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If reversing the connections does not solve the problem, adjust the phase control by synchronizing, or line-locking, the cameras to one another. ADJUSTING THE PH
Resumo do conteúdo contido na página número 18
Reinstall the Dome Bubble DOME LINER INSTALLATION If the unit is supplied with a dome liner, reinstall the liner before installing the dome bubble. To install the liner, refer to Figure 11 complete the following steps: 1. Align the studs located on the camera module with the clips on the liner. 2. Lightly pinch the sides of the liner, opposite from the clips, and place the clips over the studs. 3. Once the liner is secure, position the viewing window of the liner over the lens of the camera. 4.
Resumo do conteúdo contido na página número 19
DOME BUBBLE INSTALLATION To install the dome bubble refer to Figure 12 and complete the following steps: 1. Select the bubble (clear or smoked). 2. Align the standoffs of the bubble with the slots of the back box. 3. Turn the bubble clockwise, until it locks in place. Figure 12. Installing the Dome Bubble C2462M-D (3/08) 19
Resumo do conteúdo contido na página número 20
Service Connector An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and adjustments. To use the cable simply plug one end of the cable directly into the service connector of the ICS090, and then connect the other end to any standard BNC (VIDEO IN) connector on a monitor. To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a local electronics supply store: Qty Description 1 2.5 mm monaural headphone