Resumo do conteúdo contido na página número 1
INSTALLATION/OPERATION
®
Endura
EDI5000-AD2088
Data Interface
Interface for AD2088 Keyboard
C2688M-C (12/08)
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Compatible Products . . . . . . . . . . .
Resumo do conteúdo contido na página número 4
List of Illustrations 1 Sample System Using Endura to Record Matrix Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 Sample System Using Endura to Expand Video Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3 EDI5000 Front and Rear Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumo do conteúdo contido na página número 5
Regulatory Notices REGULATORY NOTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
Resumo do conteúdo contido na página número 6
Description ® The EDI5000 Endura data interface provides a flexible integration platform between third-party systems and the Endura IP video surveillance ™ platform. The EDI5000-AD2088 provides an interface to the American Dynamics AD2088 keyboard, allowing security personnel to integrate Endura viewing and recording components into the existing matrix system. When the data interface receives commands from the American Dynamics matrix system keyboard it routes these commands to either the ma
Resumo do conteúdo contido na página número 7
IMPORTANT NOTE. PLEASE READ The network implementations are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. Please contact your local Pelco Representative to discuss your specific requirements. MATRIX KEYBOARD CAMERA 1 MATRIX MATRIX MONITOR EDI5000 LOOPING VIDEO PLAYBACK ENCODER CAMERA 2 ENCODER DECODER ENDURA DVR
Resumo do conteúdo contido na página número 8
FRONT AND REAR PANELS Figure 3 illustrates the front and rear panels of the data interface (refer to Front Panel Indicators on page 33 for a description of the front panel LEDs; refer to Basic Hardware Connections on page 14 for a description of the rear panel connectors). Figure 3. EDI5000 Front and Rear Panels Network Activity Indicator Reset Network Speed Indicator Power Pelco Badge (power indicator) (Reserved For Future Use, Do Not Use) COM Port Indicator (COM 1 or COM 2) RS-232 Connecto
Resumo do conteúdo contido na página número 9
Installation HARDWARE INSTALLATION OVERVIEW The following steps provide an overview of how to install the data interface: 1. Install all components of the matrix switching system (refer to the matrix system documentation for instructions). 2. Install the EDI5000 data interface, and then make the following connections (instructions are provided in this Installation section): a. Connect the data interface to the matrix system keyboard. b. Connect the data interface to the Endura network. NOTE: If
Resumo do conteúdo contido na página número 10
USER-SUPPLIED PARTS In addition to the standard tools and cables required for a video security installation, you need to provide the following items: Qty Description 1 Cat5e (or better) cable with the individual wires exposed at each end (for connecting the data interface to the matrix keyboard wallblock connector) 1 Power supply; refer to Power Connection on page 16 for more information PRODUCT SERIAL NUMBER LABEL PLACEMENT The product serial number label helps identify your data interface and
Resumo do conteúdo contido na página número 11
IOIOI 1 EDI5000 IOIOI 2 WARNING: Do not place the data interface on its side; the unit could fall over and cause damage. Figure 5. EDI5000 Data Interface Desktop Placement WALL MOUNT INSTALLATION The data interface can be mounted to a wall using the optional WM5001-4U wall mount system. You can mount up to four data interface units, in any combination, in a fully expanded WM5001-4U (one WM5001-4U with up to three WM5001-4UEXP expansion units). NOTE: The maximum number of data interface un
Resumo do conteúdo contido na página número 12
3. Tighten the thumbscrew on the wall mount to secure the unit (refer to Figure 7). TIGHTEN THUMBSCREW Figure 7. Tighten the Thumbscrew to Secure the Unit RACK MOUNT INSTALLATION You can mount the EDI5000 in the optional RK5100PS-5U rack mount kit along with additional Endura devices that are compatible with this rack mount kit (such as encoders and decoders). Each unit plugs directly into a power connector in the rack and is powered by the rack. Up to 12 devices can be mounted in the RK5100PS
Resumo do conteúdo contido na página número 13
3. Tighten the thumbscrew on the rack mount to secure the unit into the rack (refer to Figure 9). TIGHTEN THUMBSCREW Figure 9. Tighten Thumbscrew to Secure the Unit PELCO BADGE ORIENTATION The Pelco badge on the front panel of the data interface can be rotated in quarter turns. If you install the unit on a flat surface, the Pelco badge will be turned the wrong way. To rotate the Pelco badge: 1. Use the Pelco badge rotation sticker that came with the unit. 2. Attach the middle portion of the rot
Resumo do conteúdo contido na página número 14
BASIC HARDWARE CONNECTIONS CONNECTING THE MATRIX SYSTEM TO THE EDI5000 Figure 11 shows how to wire the terminal block and connect it to the data interface. Note that the terminal block can be attached to the data interface only in the proper position. POWER RESERVED FOR FUTURE USE (DO NOT USE) Figure 11. Wiring the Terminal Block 1. Prepare a reversed data cable (user-supplied) with an RJ-45 connector at one end and with the individual wires exposed at the other end. 2. Connect the cable’s indi
Resumo do conteúdo contido na página número 15
5. Connect the wires at the other end to the wall block that is provided with the AD2088 keyboard. CAMERA 1 MATRIX MONITOR CAMERA 2 AD MATRIX AD2088 MATRIX KEYBOARD REVERSED REVERSED DATA CABLE DATA CABLE AD DUAL 8-PIN TERMINAL BLOCK 9 VAC 1 8 910 1 2 7 8 5 6 3 4 1 2 8 1 2 7 GND 7 2 3 6 COM 1 6 3 Tx+ Rx+ 4 5 4 5 Rx+ COM 2 Tx+ GND EDI5000-AD2088 Figure 12. Connecting the EDI5000 to the AD2088 Keyboard IMPORTANT NOTE: PLEASE READ. The network implementation is shown as a general representation
Resumo do conteúdo contido na página número 16
NETWORK CONNECTION NOTE: Consult your network administrator before installing the data interface to avoid possible network conflicts. Use the network port on the front panel and a Cat5e (or better) cable with RJ-45 connectors to connect the data interface to your system network. NETWORK Figure 13. Connecting the EDI5000 to the Endura Network POWER CONNECTION To connect power, complete the following steps: 1. Connect a power supply to the data interface. The data interface can be powered from ma
Resumo do conteúdo contido na página número 17
Power Supply Options The EDI5000 offers a single 4-pin power connector on the rear panel. The RK5100PS-5U rack mount kit and the NET5301PS power supply attach to this connector. When using a different power supply, attach power to the enclosed 4-pin to 2-pin adapter and attach the adapter to the unit. The data interface is designed to operate from either a 12 VDC or a 24 VAC power supply. It automatically senses power type and polarity (DC). The data interface can be powered from the following
Resumo do conteúdo contido na página número 18
5. When prompted with installation options, make sure to uncheck both check boxes. Figure 16. Bonjour Setup Screen When the installation is finished, Bonjour Service will be installed on the PC. If problems with the discovery ever arise, this service should be the first step in solving problems. To restart the service, do the following: 1. From the Control Panel, select Administrative Tools. 2. Click Services. 3. Find Bonjour Service in the list. Select it. 4. From the Actions menu, click Restar
Resumo do conteúdo contido na página número 19
3. After the EDI5000 is configured correctly, and you are on the same network, EDI5000 appears in the task pane. Double-click the name to display the EDI5000 login page. Figure 18. Bonjour Logon Renaming EDI5000 You can rename the EDI5000 unit (for example, if there are multiple EDI5000 units) by changing the EDI5000 host name. Refer to Configure Network Settings on page 25. C2688M-C (12/08) 19
Resumo do conteúdo contido na página número 20
Software Configuration SOFTWARE CONFIGURATION OVERVIEW Once the hardware is installed and all devices are connected, complete the following software configuration tasks: 1. Configure the data interface settings through the EDI5000 system configuration software. Instructions are provided in Change Configuration Settings on page 23. NOTE: Configuring the settings for the EDI5000 system configuration software includes setting the camera offset value, which is used to differentiate matrix system c