Resumo do conteúdo contido na página número 1
60kW InfraStruXure PDU
PD60H5HK1
PDRPPH1000
Operation and Configuration
400/230V
Resumo do conteúdo contido na página número 2
Resumo do conteúdo contido na página número 3
About This Manual Audience This manual is intended for end-users of a 60kW InfraStruXure PDU. It covers the operation, customization, and quick configuration of the PDU, and includes basic InfraStruXure system operation. Companion manuals For additional information about the InfraStruXure system, see the Installation and Start-Up manual (990-1637B) included with the PDU. It covers the installation and start-up of the PDU, power distribution to the rack, and power distribution within the rac
Resumo do conteúdo contido na página número 4
Resumo do conteúdo contido na página número 5
Contents Safety ......................................................................1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Save these instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety symbols used in this manual . . . . . . . . . . . . . . . . . . . 1 Cross-reference symbols used in this manual . . . . . . . . . . . . . 1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resumo do conteúdo contido na página número 6
Alarms Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 View Active Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Alarm/Event Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Alarm Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Alarm Beeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 PDU Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Resumo do conteúdo contido na página número 7
Communication Configuration................................31 InfraStruXure PDU Management Options. . . . . . . . . . . . . . . . . 31 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 InfraStruXure Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Network management interfaces . . . . . . . . . . . . . . . . . . . . 31 Configuring the InfraStruXure Manager . . . . . . . . . . . . . . . . . . 32 Configuring the Network Management Interface . . . .
Resumo do conteúdo contido na página número 8
How to Test the Emergency Power Off Switch . . . . . . . . . . . . . 49 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Testing the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Emergency Power Off (EPO) . . . . . . . . . . . . . . . . . . . . . . . 51 How to Download Firmware Upgrades . . . . . . . . . . . . . . . . . . 52 Specifications ........................................................ 55 Product Information ...................
Resumo do conteúdo contido na página número 9
Safety Overview Save these instructions This manual contains important instructions that must be followed during installation, operation, and maintenance of the PDU. Safety symbols used in this manual Indicates an electrical hazard, which, if not avoided, could result in injury or death. Electrical Hazard Indicates a hazard, which, if not avoided, could result in personal injury or damage to product or other property. Warning Indicates a potential hazard which could result in damage to produc
Resumo do conteúdo contido na página número 10
Warnings Unpacking/moving DO NOT tilt the PDU greater than 45° from its vertical axis. Never lay the PDU on its side. Installation/maintenance Only a certified electrician can perform these tasks: Connect the PDU to its power source Connect a switch to the EPO interface on the PDU Only a certified electrician or an APC Field Service Engineer can perform maintenance of the PDU. When you connect the PDU to its power source, you must install a 125A circuit breaker to protect the PDU against o
Resumo do conteúdo contido na página número 11
Safety Emergency Power Off (EPO) This InfraStruXure PDU is provided with an Emergency Power Off switch connection. When this EPO switch is energized, electrical power to the units is de-energized and the system will not transfer to on-battery operation. EPO can be achieved with either a contact closure or application of an external 24VAC or 24VDC from a SELV or PELV source. Its important to note that hazardous voltage from the Mains voltage must be isolated from the contact closure or 24VAC
Resumo do conteúdo contido na página número 12
Resumo do conteúdo contido na página número 13
PDU Display Interface Overview Use the display interface to configure settings, set alarm thresholds, and provide audible and visual alarms. Load Powered ESC Check Log ? Bypass Alarm Load Powered LED When green, all output phases are within the limits specified by the output alarm limit thresholds. Check Log LED When yellow, at least one new alarm condition has been detected. Bypass LED Not used on this model PDU. Alarm LED When red, an alarm condition exists. LCD V
Resumo do conteúdo contido na página número 14
PDU Display Interface Top-level status screens After displaying a brief start-up screen after system start-up, the display interface scrolls automatically and continuously through four screens of basic status information. Press the Up and Down arrow keys to interrupt the automatic scrolling to view a specific status screen. Volts In Volts Out Load Current L1-2: 000 L1: 000 L1: 000 Neut: 000 L2-3: 000 L2: 000 L2: 000 L3-1: 000 L3: 000 L3: 000 Total Output Loading No Active Alarms kW: 000 PF: 00
Resumo do conteúdo contido na página número 15
PDU Display Interface On some screens, continue arrows ( indicate that there System/Network are additional screens to view in the category. Press the Up Electrical Configuration Panel Configuration or Down arrow key to view the additional screens. Manufacturer Data Product Data Factory Defaults Firmware Updates Password-protected screens When configuring or changing settings, you will be prompted for your password. To enter your password: 1. Press the Up or Down arrow key until the corr
Resumo do conteúdo contido na página número 16
Load-Meter Screen From the Load-Meter screen, you can select the following items: Total Load by Phase The load supported by each phase in kVA, in RMS current (Irms), and as a percentage of the maximum allowable load (%LD). Total Load Summary For the total load supported: kW: The power provided, in kilowatts. kVA: The actual power drawn by the load, in kilovolt-amperes. Freq: Frequency PF: The power factor (kW/kVA), which affects the power available to the load. %LD: The load as a p
Resumo do conteúdo contido na página número 17
Volt-Meter Screen From the Volt-Meter screen, you can select the following items: Output Voltage Displays each phase-to-phase output voltage (e.g., L1-2 for phase L1 to phase L2) and each phase-to-neutral output voltage (e.g., L1 for phase L1 to neutral). Input Voltage Displays each phase-to-phase input voltage (e.g., L1-2 for phase L1 to L2), or each phase-to-neutral input voltage (e.g., L1 for phase L1 to neutral). 60kW InfraStruXure PDU—Operation and Configuration 9
Resumo do conteúdo contido na página número 18
Contacts Screen Overview The PDU can monitor external contact closure events. Possible applications include the following: Magnetic contact switches Window foil Tamper switches Heat detectors Water sensors Pressure sensors Building smoke and fire detection systems You can set input contacts to cause alarm conditions based on their current state and a user-defined normal state. Relay outputs can map internal alarms and events to outside devices. Use the Contacts screen to display
Resumo do conteúdo contido na página número 19
PDU Display Interface Alarm Relay Map Configure the relay outputs, using the Alarm Relay Map. Each Alarm Map corresponds to a relay output. For example, Alarm Map 01of04 corresponds to the first of four relay outputs. The second line, in brackets [ ], lists the items that you have selected to map to the selected relay/ The third line allows you to select the alarms to which you want to map the relay: Any Load (L)Maps to over- or under-current alarms for circuit breaker panels and branch
Resumo do conteúdo contido na página número 20
PDU Display Interface How to connect contacts to the PDU monitoring unit 1. Choose one or more contact numbers on the user connection plate to which you will connect the contacts. The user connection plate connects to the User/EPO port on the PDU monitoring unit. 2. From the PDU display interface: a. Press the ESC or ENTER key to go to the top-level menu screen. b. Select Contacts on the top-level menu screen, and press the ENTER key. Load-Meter Alarms Volt-Meter Panel Config Contacts Help Br